Haier HSU-09HSA03/R2(DB) user manual

User manual for the device Haier HSU-09HSA03/R2(DB)

Device: Haier HSU-09HSA03/R2(DB)
Category: Air Conditioner
Manufacturer: Haier
Size: 1.36 MB
Added : 8/12/2013
Number of pages: 90
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Haier HSU-09HSA03/R2(DB). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Haier HSU-09HSA03/R2(DB).

For your convenience

If looking through the Haier HSU-09HSA03/R2(DB) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Haier HSU-09HSA03/R2(DB) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Haier HSU-09HSA03/R2(DB) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Haier HSU-09HSA03/R2(DB) User manual - Online PDF
Advertisement
« Page 1 of 90 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Haier HSU-09HSA03/R2(DB) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Haier HSU-09HSA03/R2(DB). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Haier air conditioner Edition: 20070116
Domestic
Air conditioner
HSU-09HSA03/R2(DB)
HSU-12HSA03/R2(DB)
CAUTION
 READ THIS MANUAL
CAREFULLY TO
DIAGNOSE TROUBLE
CORRECTLY BEFORE
OFFERING SERVICE.
 THIS MANUAL IS USED
BY QUALIFIED
APPLIANCE
TECHNICIANS ONLY.
 HAIER DOES NOT
ASSUME ANY
RESPONSIBILITY FOR
PROPERTY DAMAGE
OR PERSONAL INJURY
FOR IMPROPER
SERVICE
PROCEDURES DONE
BY ONE UNQUALIFIED
PERSON.
-1-

Summary of the content on the page No. 2

Haier air conditioner Edition: 20070116 CONTENTS 1. GENERAL INFORMATION...............................................................3 2. SPECIFICATION...............................................................................6 3. ELECTRICAL CONTROL..................................................................8 4. THERMISTER RESISTANCE CHART.............................................30 5. TROUBLE SHOOTING....................................................................40 6. PERFORM

Summary of the content on the page No. 3

Haier air conditioner Edition: 20070116 1. General information This Service Manual describes the operation, disassembly, troubleshooting, and repair of Haier Room Air Conditioners, etc. It is intended for use by authorized services who troubleshoot and repair these units. It is assumed that users of this manual are familiar with the use of tools and equipment used to troubleshoot and repair electrical, mechanical, and refrigeration systems; and understand the terminology used to describe and

Summary of the content on the page No. 4

Haier air conditioner Edition: 20070116 MODEL: HSU-09HSA03/R2(DB) Product Features  Healthy negative ion  Intelligent airflow  Entire auto mode  ESF filter  Easy clean design Main Specification  Cooling Capacity: 2400W  Power Input: 680W  Current Input:3.50A  EER:3.53  Heating Capacity: 2650W  Power Input:730W  Current Input: 3.8A  COP: 3.63 3  Air Volume(Indoor/outdoor): 400m /h  Power Supply: 1PH/230V/ 50Hz -4-

Summary of the content on the page No. 5

Haier air conditioner Edition: 20070116 MODEL: HSU-12HSA03/R2(DB) Product Features  Healthy negative ion  Intelligent airflow  Entire auto mode  ESF filter  Easy clean design Main Specification  Cooling Capacity: 3300W  Power Input: 1078W  Current Input: 4.9A  EER:3.06  Heating Capacity: 3600W  Power Input:1230W  Current Input: 5.4A  COP: 2.93 3  Air Volume(Indoor/outdoor): 450m /h  Power Supply: 1PH/230V/ 50Hz -5-

Summary of the content on the page No. 6

Haier air conditioner Edition: 20070116 2. Specification HSU-09HSA03 HSU-12HSA03 Item Unit /R2(DB) /R2(DB) Power PH, V, Hz 1, 230, 50 1,230,50 Climate Type T1 T1 Starting Current A 10 12 Cooling Capacity W 2400 3300 Rated Power W 680 1078 Rated Current A 3.50 4.9 Cooling Max Power W 870 1350 Max Current A 3.8 6.0 EER W/W 3.53 3.06 Heating Capacity W 2650 3600 Rated Power W 730 1230 Rated Current A 3.8 5.4 Heating Max Power W 1100 1480 Max Current A 4.4 6.8 EER W/W 3.63

Summary of the content on the page No. 7

Haier air conditioner Edition: 20070116 Type R410A R410A Net Charge g 800 1200 Refrigerant Charge if over standard pipe g/m 12 12 length Liquid pipe Diameter mm 6.35 6.35 Gas pipe Diameter mm 9.52 12.7 Refrigerant Pipe Standard length m 5 5 Max length m 15 15 Length mm 2000 2000 Drain Hose Diameter mm 16 16 Drainage pipe material diameter mm 16 16 Remote Controller Model YR-H04 YR-H04 Class of electric Shock Protection I I Class of Water Proof IP 24 IP 24 2 2 Power Cord (Model × Sectional Area

Summary of the content on the page No. 8

Haier air conditioner Edition: 20070116 3. Electrical control . Scope of Application This specification use for HSU-09/12HSA03/R2 DB frequency conversion air condition are manufactured by Haier air condition parent company. "Setting value" (express in parameter) in this specification means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter table]. 1. Chip pin definition This controller adopts MOTROLA MC68HC908 AB32; Chip each pin definition as following: 1 PTC4 door switch

Summary of the content on the page No. 9

Haier air conditioner Edition: 20070116 32 PA6 pushup stepping motor C 33 PA7 pushup stepping motor D 34 PTB0/ATD0 output outdoor communication 35 PTB1/ATD1 input outdoor communication 36 PTB2/ATD2 room temperature 37 PTB3/ATD3 inner coil 38 PTB4/ATD4 swing left stepping motor D 39 PTB5/ATD5 swing left stepping motor C 40 PTB6/ATD6 swing left stepping motor B 41 PTB7/ATD7 swing left stepping motor A 42 PTD0 swing right stepping motor D 43 PTD1 swing right stepping motor C 44 VDDAREF VCC 45 AVSS/

Summary of the content on the page No. 10

Haier air conditioner Edition: 20070116 2.1.1 Standard of temperature sensor under indoor environment. When the line is in short circuit or open circuit, the indicator light will be alarming and the indoor fan motor will be off. It will resume to the original state automatically after it returns normally, and operates as usual. Short circuit: Temperature: above 126 degrees, Hex: Above F8H, Value of Resistance: Below 0.65K, above 4.85V. Normal temperature: Temp: 25 degrees, Hex: 40H, Value o

Summary of the content on the page No. 11

Haier air conditioner Edition: 20070116 Corrected Mode Corrected contents Corrected variable parameter Correct the operating mode ETBL0 4.67 Correct forced operating mode ETBL1 6 When the air capacity is low to Heat ETBL2 4.67 correct it When the air capacity is low to ETBL3 4.67 correct it Cool and Correct the operating mode ETBL4 -0.33 dry mode Correct the forced operating mode ETBL5 -4 2.4 Control the temperature the area 2.4.1 Deviation Calculation the deviation of the temperature a

Summary of the content on the page No. 12

Haier air conditioner Edition: 20070116 When the system is in test run, emergency operation, silencing operation mode, the DASH will be stopped. 2.4.5 Temperature adjustment section DASH operation condition in the different mode 2.4.6 Frequency in the different mode In this area, the frequency (from indoor to outdoor) indication as following: When the system is in the cool and dry mode, the frequencies between A area and B area are same. In the silencing operation mode, the frequencies betwe

Summary of the content on the page No. 13

Haier air conditioner Edition: 20070116 Controlling table in the identity area Temperature change area AB C D E F G H Heat FQUP(2Hz) FQUP(2Hz) FQUP(2Hz) FQUP(1Hz) FQUP(1Hz) Cool and dry FQUP(2Hz) FQUP(2Hz) FQUP(2Hz) FQUP(1Hz) FQUP(1Hz) FQUPH 2Hz FQUPL 1Hz 2.4.8 Air capacity decision when Air capacity is running automatically. When air capacity is running automatically, based on temperature adjusting sections, you shift the switch for air capacity, namely, enhanced, middle, and weak. When

Summary of the content on the page No. 14

Haier air conditioner Edition: 20070116 correction the limit frequency according to the following condition: Outdoor temperature condition Indication frequency 011(20 more than) Low fan or health fan limited frequency 48Hz 010(15-20 ) Low fan or health fan limited frequency 50Hz +FUPHEA1 001(10-15 ) Low fan or health fan limited frequency 52Hz +FUPHEA2 000(10 downward) In general frequency . Indoor fan motor control Objective revolutions: When air capacity is set

Summary of the content on the page No. 15

Haier air conditioner Edition: 20070116 Based on the heat exchange temperature to control the indoor fan as the above shown. 1. When the heat exchange temperature rise, to distinguish the fan speed based on the heat exchange temperature: The heat exchange temperature is less than 35.2 , the speed of fan motor is weak (for the first power on, when the system operating in heat mode or OFF the defrost mode, and when the heat exchange temperature is less than 25.2 , the fan motor will OFF; if t

Summary of the content on the page No. 16

Haier air conditioner Edition: 20070116 3.1.2 Compressor OFF and waiting for 3 minutes 1. The compressor is OFF (the flamestat is OFF), the air capacity will change from small to little small after 20 seconds (is SSLO in silence mode); 2. To heat operating in stand-by time (when the mode switch, the compressor will OFF), the air capacity keep to weak. 3. Power off by remote control then the indoor fan motor will OFF. 3.1.3 Compressor restart It is set air capacity by remote control after the

Summary of the content on the page No. 17

Haier air conditioner Edition: 20070116 3.3.2 Compressor ON When the air capacity is set High, Middle and Low, the compressor will operate by the set mode. When the air capacity is set auto fan, the air capacity will be adjusted by the temperature. . Enhanced operation Enhanced operation will continue for 15 minutes. Enhanced operation will finish if the operation is off or after 15 minutes. Enhanced operation will finish when the status be changed. Enhanced operation will finish if the unit e

Summary of the content on the page No. 18

Haier air conditioner Edition: 20070116 After compressor starts, it’s not on the low load protection within 3 minutes. 4.3 No enhanced function for fan and defrosting mode. .Silence operation Send silence operation signal to outdoor unit. 5.1 Heating in the silence mode When compressor is on, air capacity is SSLO. When compressor is off, air capacity is SSLO within 20 seconds, and then it changes to be tenuity. 5.2 Cooling in the silence mode Air capacity is SSLO. 5.3 No silence functions dur

Summary of the content on the page No. 19

Haier air conditioner Edition:20070116 7.3 Timer ON/OFF The executing order is based on the direction from the board. . Sleep operating 8.1 During cool/ dry operation, the fixed temperature will rise by 1 after it operates for 1 hour. After another hour the temperature will rise by another 1 . After 6 hours, the unit is off. 8.2 During heat-making operation, the fixed temperature will rise by 2 after 1 hour. After another 2 hours the temperature will rise by 2 . The temperature will rise by

Summary of the content on the page No. 20

Haier air conditioner Edition:20070116 When the system switch from other mode to auto mode, if the operation status change (i.e. first determine and then operation), it will stop for 3 minutes and then determine temperature based on the indoor ventilation temperature. 9.2 Full-automation operation After system is on and the operation mode will switches to auto mode, the system determine operating mode by the difference between current set temperature and the room temperature, and then operate


Alternative user manuals
# User manual Category Download
1 Haier 0010515194 User manual Air Conditioner 1069
2 Haier 0010506358 User manual Air Conditioner 90
3 Haier 0010515690 User manual Air Conditioner 40
4 Haier 0010518181 User manual Air Conditioner 28
5 Haier 0010518358 User manual Air Conditioner 42
6 Haier 0010516146 User manual Air Conditioner 29
7 Haier 0010518526 User manual Air Conditioner 20
8 Haier 001051 User manual Air Conditioner 25
9 Haier 0010530627 User manual Air Conditioner 38
10 Haier 0010515222 User manual Air Conditioner 16
11 Haier 0010552537 User manual Air Conditioner 18
12 Haier 0010554405B User manual Air Conditioner 5
13 Haier 0010557172 User manual Air Conditioner 12
14 Haier 0010571223 User manual Air Conditioner 12
15 Haier 0010571570 User manual Air Conditioner 11
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21