Haier HSU-09HEA03/(BP) user manual

User manual for the device Haier HSU-09HEA03/(BP)

Device: Haier HSU-09HEA03/(BP)
Category: Air Conditioner
Manufacturer: Haier
Size: 3.02 MB
Added : 5/29/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Haier HSU-09HEA03/(BP). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Haier HSU-09HEA03/(BP).

For your convenience

If looking through the Haier HSU-09HEA03/(BP) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Haier HSU-09HEA03/(BP) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Haier HSU-09HEA03/(BP) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Haier HSU-09HEA03/(BP) User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Haier HSU-09HEA03/(BP) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Haier HSU-09HEA03/(BP). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HEA03/(BP)
HSU-12HEA03/(BP)
Please read this operation manual before using the air conditioner.
0010518526

Summary of the content on the page No. 2

Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully. The User's Guide contains very impor- in order to avoid the risk of child entrapment. tant observations relating to the assembly, operation and maintenance of the air It must be noticed that

Summary of the content on the page No. 3

Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver. 8. Young children should be supervised to ensure that they do not play with Do not allow children to play with the air the applience. conditioner.In no case should children be allowed to sit on the outdoor unit. 9.Please

Summary of the content on the page No. 4

Parts and Functions Indoor Unit Outlet Display board Inlet Air filter(inside) Air Purifying Filter (inside) Power plug Inlet grille Horizontal flap Anion generator (adjust up and down air flow. (inside) Don't adjust it manually) Vertical blade (adjust left and right air flow) Actual inlet grille may vary from the one shown in the manual according to the product purchased Outdoor Unit HSU-09HEA03/(BP) HSU-12HEA03/(BP) OUTLET CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE 3

Summary of the content on the page No. 5

Parts and Functions Display board Remote controller 1 6 7 2 ON OFF A 8 U o AM T 25 1 26 4 1 8 9 O PM 5 C 3 9 4 7. SIGNAL SENDING display 10 8. TIMER OFF display 11 9. TIMER ON display ON/OFF TEMP 10. CLOCK display 5 11. TEMP display 12 12. POWER ON/OFF 19 Used for unit start and stop. MODE SET 13. MODE 20 13 Used to select COOL,DRY,HEAT operation 14. FAN TIMER FAN Used to select fan speed AUTO, HI, MED, LO 21 15. HOUR 14 Used to set clock and timer setting. 15 16. SWING CLOCK SWING Used to set

Summary of the content on the page No. 6

Operation Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering t

Summary of the content on the page No. 7

Operation Cool Operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: ON/OFF TEMP COOL DRY HEAT 1 4 MODE SET Unit will run in operation mode displayed on LCD. 2 Stop display at your desired mode. FAN TIMER 3 (3) Select temp. setting SWING CLOCK Press TEMP button. o Every time the button is pressed, temp. setting increases 1 C o HEAL

Summary of the content on the page No. 8

Operation Heat Operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: COOL DRY HEAT ON/OFF TEMP Unit will run in operation mode displayed on LCD. 3 1 3 5 Stop display at your desired mode. MODE SET (3) Select temp. setting 2 FAN TIMER Press TEMP button. o 4 Every time the button is pressed, temp. setting increases 1 C o SWING CLOCK

Summary of the content on the page No. 9

Operation Dry Operation (1) Unit start Press ON/OFF button, unit starts. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: HEAT COOL DRY ON/OFF TEMP Unit will run in operation mode displayed on LCD. 3 1 3 6 Stop display at your desired mode. MODE SET (3) Select temp. setting 2 FAN TIMER Press TEMP button. o Every time the button is pressed, temp. setting increases 1 C 4 o Every time the button is pressed, temp. setting decreases 1 C SWING CLOCK Unit

Summary of the content on the page No. 10

Operation (5) Air flow direction adjustment After operation mode is selected, horizontal flap will open automatically according to the mode. Referring to the Fig. COOL o About 10 Up and down (Use remote controller) Left and right air flow adjustment Press SWING button, horizontal flap will move (manual) Move the vertical blade by a knob on air within the range shown in the Fig. Press SWING conditioner to adjust left and right direction button stop it at a fixed position. referring to Fig. o Abo

Summary of the content on the page No. 11

Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2)TIMER mode selection ON Press TIMER button to change TIMER mode. Every time the button is pressed, display

Summary of the content on the page No. 12

Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this funciton. ON/OFF TEMP Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed,display MODE SET changes as follows: BLANK FAN TIMER SOFT POWER Stop the display at SWING CLOCK In POWER operation status: In COOL mode, fan speed automatically runs in HI mode HEALTH POWER/SOFT for 15 min then returns to original status setting. To cancel POWER operation LOCK RESET P

Summary of the content on the page No. 13

Operation Emergency operation and test operation Emergency Operation: Carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a" Pi "sound starts once, which means the start of this operation. In this operation, it is not possible to change the settings of temperature and air flow speed, it is Pi also impossible to do an operation by the timer. Follow the requirements below. Room Timer Designated Air flow Operation temper

Summary of the content on the page No. 14

Maintenance Replacement of Air Purifying Filter 1.Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the ind- oor unit. 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Attach Air Purifying Filter Put air purifying filter appliances into the Detach old Air Purifying Filter right and left filter frames. 4.Attach the standard air filter (Necessary installation)

Summary of the content on the page No. 15

Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. OFF 14

Summary of the content on the page No. 16

Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water

Summary of the content on the page No. 17

Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT OFF ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT STRICT PROHIBITION ENFORCEMENT ENFORCEMENT Take care not to damage Do not insert objects into the air Do not use power supply cord the power supply cord. in

Summary of the content on the page No. 18

Trouble shooting Before asking for service, check the following first. Phenomenon Cause or check points The system does not restart When unit is stopped, it won't restart immediately until 3 minutes have elapsed immediately. to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this


Alternative user manuals
# User manual Category Download
1 Haier 0010515194 User manual Air Conditioner 1069
2 Haier 0010506358 User manual Air Conditioner 90
3 Haier 0010515690 User manual Air Conditioner 40
4 Haier 0010518181 User manual Air Conditioner 28
5 Haier 0010518358 User manual Air Conditioner 42
6 Haier 0010516146 User manual Air Conditioner 29
7 Haier 0010518526 User manual Air Conditioner 20
8 Haier 001051 User manual Air Conditioner 25
9 Haier 0010530627 User manual Air Conditioner 38
10 Haier 0010515222 User manual Air Conditioner 16
11 Haier 0010552537 User manual Air Conditioner 18
12 Haier 0010554405B User manual Air Conditioner 5
13 Haier 0010557172 User manual Air Conditioner 12
14 Haier 0010571223 User manual Air Conditioner 12
15 Haier 0010571570 User manual Air Conditioner 11
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21