Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04 user manual

User manual for the device Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04

Device: Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04
Category: Air Conditioner
Manufacturer: Haier
Size: 0.95 MB
Added : 5/29/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04.

For your convenience

If looking through the Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04 User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Haier HSU-09HV04, HSU-12HV04, HSU-18HV04, HSU-22HV04. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HV04/R2(DB)
HSU-12HV04/R2(DB)
HSU-18HV04/R2(DB)
HSU-22HV04/R2(DB)
Please read this operation manual before using the air conditioner
No.0010556804

Summary of the content on the page No. 2

Cautions Safety Instructions and Warnings Disposal of the old air conditioner Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the Operation manual erative and safe. Unplug the air conditioner carefully. The Operation manual contains in order to avoid the risk of child entrapment. very important observations relating to the assembly, operation and maintenance of It must be noticed that air

Summary of the content on the page No. 3

Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver. 8. Young children should be supervised to ensure that they do not play with Do not allow children to play with the air the applience. conditioner.In no case should children be allowed to sit on the outdoor unit. 9.Ple

Summary of the content on the page No. 4

Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water

Summary of the content on the page No. 5

Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT OFF ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT STRICT PROHIBITION ENFORCEMENT ENFORCEMENT Take care not to damage Do not insert objects into the air Do not use power supply cord the power supply cord. in

Summary of the content on the page No. 6

Parts and Functions Indoor unit Outlet Display board Air filter(inside) Inlet Air Purifying Filter (inside) Inlet grille Negative ion generator (inside) Vertical flap (adjust up and down air flow. Power plug Don't adjust it manually) Horizontal louver (adjust left and right air flow) Outdoor unit HSU-09HV04/R2(DB) HSU-22HV04/R2(DB) HSU-18HV04/R2(DB) HSU-12HV04/R2(DB) 1 3 OUTLET CONNECTING PIPING AND ELECTRICAL WIRING 2 4 INLET DRAIN HOSE 5

Summary of the content on the page No. 7

Parts and Functions 16 31 10 14 21 15 19 10. TIMER ON display 11. FAN SPEED display LOW MED HI AUTO 12. LOCK display 13. SWING UP/DOWN display 14. SLEEP display 15. HEALTH display 16. Operation mode display 28 Operation mode AUTO COOL DRY HEAT FAN Remote controller 30 Display board 17.Singal sending display 18. POWER/SOFT display 19. Left/right air flow display 20. TEMP display Remote controller: to display the TEMP. setting. 21. TIMER OFF display 22. TIMER display 1.RESET 23. TEMP button Wh

Summary of the content on the page No. 8

Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. POWER/SOFT 2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly. 3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. Remote controller's operation Whe

Summary of the content on the page No. 9

Operation HEALTH operation Remote controller 1.Unit start Press ON/OFF on the remote controller, unit starts. 2.Health negative ion function Press HEALTH button. For each press, is displayed. Air conditioner starts health negative ion function operation. For twice press, disappears,the operation stops. POWER/SOFT When indoor fan motor is running, it has healthy process function. (It's available under any mode) When the fan motor in the indoor unit does not work, the health lamp lig

Summary of the content on the page No. 10

Operation Auto Operation Remote controller 1. Unit start Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select Auto operation On the displaying board,colorful displaying bar will be white. 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: POWER/SOFT Remote controller: LOW MED HI AUTO Air conditioner is running under

Summary of the content on the page No. 11

Operation Cool Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select COOL operation On the displaying board,colorful displaying bar will be blue. 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly POWER/SOFT Every tim

Summary of the content on the page No. 12

Operation Dry Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select DRY operation On the displaying board,colorful displaying bar will be light blue 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase POWER/SOFT rapidly Every

Summary of the content on the page No. 13

Operation Fan Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select FAN operation On the displaying board,colorful displaying bar will be pink. 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: POWER/SOFT LOW MED HI 4.Unit stop Press ON/OFF button, the uni

Summary of the content on the page No. 14

Operation Heat Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select HEAT operation On the displaying board,colorful displaying bar will be red 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase POWER/SOFT rapidly Every time

Summary of the content on the page No. 15

Operation Air Flow Direction Adjustment 1.Status display of air sending Vertical flap Horizontal louvers Pos.1 Pos.1 Pos.2 Pos.2 Pos.3 Pos.3 Pos.4 Pos.4 POWER/SOFT Pos.5 Pos.5 Pos.6 Pos.6 (Auto swing) Pos.7 Pos.8 2.Up and down air flow direction For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN remote controller: Pos.1 Pos.2 Pos.3 Pos.4 Pos.6 : HEAT: remote controller: Pos.5 Pos.4 Pos.3 Pos.2 Pos.1 P

Summary of the content on the page No. 16

Operation Sleep Operation SLEEP operation starts SLEEP operation stops Approx.6hrs Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP Rises 1OC 1 hr mode and bring you a sound sleep. Use of SLEEP function Rises 1OC 1 hr After the unit starts, set the operation status, then press SLEEP button before which the Unit stop Temp.setting clock must be adjusted and time being set. In COOL, DRY mode Operation Mode In HEAT mode 1. In COOL,DRY mode 2. 1 hours after

Summary of the content on the page No. 17

Operation Timer On/Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Remote Controller Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash. 3.T

Summary of the content on the page No. 18

Operation Timer On-Off Operation Set clock correctly before starting TIMER operation. Remote Controller 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON - OFF). " "will flash. 3.Time setting Press H

Summary of the content on the page No. 19

Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this funciton. Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed,display changes as follows: BLANK POWER SOFT Stop the display at In POWER operation status: In HEAT or COOL mode, fan speed automatically runs in AUTO mode for 15 min then returns to original status setting. To cancel POWER operation Press POWER/SOFT button twice ,POWER/SOFT disappears. SOFT Operat

Summary of the content on the page No. 20

Operation Health airflow Operation 1.Press ON/OFF to starting Remote controller The liquid crystal will display the working state of last time (Except timer, sleeping, power/soft and health airflow). Setting the comfort work conditions. 2.The setting of health airflow function 1).Press the button of health airflow, appears on the display. The bottom inlet and outlet grills of the air condit- ioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avo


Alternative user manuals
# User manual Category Download
1 Haier 0010515194 User manual Air Conditioner 1069
2 Haier 0010506358 User manual Air Conditioner 90
3 Haier 0010515690 User manual Air Conditioner 40
4 Haier 0010518181 User manual Air Conditioner 28
5 Haier 0010518358 User manual Air Conditioner 42
6 Haier 0010516146 User manual Air Conditioner 29
7 Haier 0010518526 User manual Air Conditioner 20
8 Haier 001051 User manual Air Conditioner 25
9 Haier 0010530627 User manual Air Conditioner 38
10 Haier 0010515222 User manual Air Conditioner 16
11 Haier 0010552537 User manual Air Conditioner 18
12 Haier 0010554405B User manual Air Conditioner 5
13 Haier 0010557172 User manual Air Conditioner 12
14 Haier 0010571223 User manual Air Conditioner 12
15 Haier 0010571570 User manual Air Conditioner 11
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21