KitchenAid RANGE HOOD LINER with INTERNAL BLOWER user manual

User manual for the device KitchenAid RANGE HOOD LINER with INTERNAL BLOWER

Device: KitchenAid RANGE HOOD LINER with INTERNAL BLOWER
Category: Ventilation Hood
Manufacturer: KitchenAid
Size: 0.74 MB
Added : 2/20/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KitchenAid RANGE HOOD LINER with INTERNAL BLOWER. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KitchenAid RANGE HOOD LINER with INTERNAL BLOWER.

For your convenience

If looking through the KitchenAid RANGE HOOD LINER with INTERNAL BLOWER user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KitchenAid RANGE HOOD LINER with INTERNAL BLOWER on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KitchenAid RANGE HOOD LINER with INTERNAL BLOWER to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KitchenAid RANGE HOOD LINER with INTERNAL BLOWER User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KitchenAid RANGE HOOD LINER with INTERNAL BLOWER but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KitchenAid RANGE HOOD LINER with INTERNAL BLOWER. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

36" (91.4 cm) and 48" (121.9 cm)
RANGE HOOD LINER with INTERNAL BLOWER
Installation Instructions and Use and Care Guide
DOUBLURE DE HOTTE avec VENTILATEUR INTERNE
36" (91,4 cm) et 48" (121,9 cm)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
Model/Modèle
48" (121,9 cm)
Model/Modèle
36" (91,4 cm)
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE O

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES SÉCURITÉ DOUBLURE DE HOTTE DE CUISINIÈRE . . . . . . . .14 RANGE HOOD LINER SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . .2 EXIGENCES D'INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . .16 INSTALLATION REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . .4 Outillage et pièces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Tools and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON w

Summary of the content on the page No. 4

INSTALLATION REQUIREMENTS Location Requirements Tools and Parts Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed Hood location should be away from strong draft areas, such as here. windows, doors and strong heating vents. Tools needed: Installation clearance dimensions that are shown must be used. Given dimensions provide minimum clearance. ■ level NOTE: Hood li

Summary of the content on the page No. 5

Product Dimensions 48" (121.9 cm) model 47 ¹³⁄₁₆" (121.4 cm) center line 20 ³⁄₈" 2 ³⁄₄" (51.8 cm) (7.0 cm) 20 ¹⁄₄" (51.4 cm) 22" ¹⁵⁄₁₆" (2.4 cm) (55.9 cm) 17 ⁵⁄₁₆" dia. 7 ⁷⁄₈" (44.0 cm) (20.0 cm) 9 ³⁄₈" ⁷⁄₃₂" (5.6 mm) (23.8 cm) dia. ³⁄₄" (19.1 mm) 14 ¹⁄₈" (35.9 cm) 2" (5.1 cm) 35 ⁵⁄₈" 5 ¹⁵⁄₁₆" (90.5 cm) (15.1 cm) 43 ⁷⁄₁₆" (110.3 cm) 2 ³⁄₁₆" (5.6 cm) 36" (91.4 cm) model 35¹³⁄₁₆" center line (91.0 cm) 9³⁄₈" 2³⁄₄" 14³⁄₁₆" (23.8 cm) (7.0 cm) (36.0 cm) ¹⁵⁄₁₆" (2.4 cm) 22" dia. (55.9 cm) 9³

Summary of the content on the page No. 6

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed. Venting Requirements roof cap ■ 36" (91.4 cm) model requires a 6" (15.2 cm) round vent system. 48" (121.9 cm) model requires two 6" round vent systems or a 10" (25.4 cm) round system using vent transition 6" 6" kit number 4396915. (15.2 cm) (15.2 cm) ■ Vent system must terminate to the outside. round vent round vent wall cap ■ Do not terminate the vent system in an attic or other enclosed a

Summary of the content on the page No. 7

connections must conform with the rating of the appliance as specified on the model/serial rating plate. Electrical Requirements ■ Wire sizes must conform to the requirements of the National IMPORTANT: The hood must be electrically grounded in Electrical Code, ANSI/NFPA 70, latest edition, or CSA accordance with local codes and ordinances, or in the absence of Standards C22.1-94, Canadian Electrical Code, Part 1 and local codes, with the National Electrical Code, ANSI/NFPA 70, C22.2 No. 0-M91, l

Summary of the content on the page No. 8

4. ■ If using the rear electrical knockout, drill a 1¹⁄₄" (3.0 cm) Make Electrical Connection dia. hole through the wall at the location shown. hood support centerline (front view) of hood A WARNING 2" (5.1 cm) Hood size A 36" (91.4 cm) 14³⁄₁₆" (36.0 cm) Electrical Shock Hazard ■ If using the top electrical knockout, drill a 1¹⁄₄" (3.0 cm) Disconnect power before servicing. dia. hole through the hood support at the location shown. Replace all parts and panels before operating. Failure to do so c

Summary of the content on the page No. 9

Complete Installation WARNING 1. Connect vent system to hood liner. 2. Seal joints with duct tape. Check Operation Electrical Shock Hazard A Electrically ground blower. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. 6. Connect ground wire to the ground screw connector. B A C D C B A. Controls B. Light switch D C. Blower switch D. Blower speed control switch 1. Move the light switch to the “1” position. The light should turn

Summary of the content on the page No. 10

RANGE HOOD USE RANGE HOOD CARE Operation Cleaning and Maintenance The canopy hood is designed to remove smoke, cooking vapors Be sure lights are cool before cleaning the hood. and odors from the cooktop area. For best results, start the hood Exterior surfaces before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the ■ Do not use steel wool or soap-filled scouring pads. kitchen. ■ Rub in direction of the grain line to avoid marring

Summary of the content on the page No. 11

REQUESTING ASSISTANCE OR SERVICE If you need assistance or service in U.S.A. If you need assistance or service in Canada Call the KitchenAid Customer eXperience Center toll-free at For product related questions, please call the KitchenAid Canada 1-800-422-1230. Our consultants are available to assist you. Inc. Customer eXperience Centre toll free: 1-800-807-6777 Monday to Friday 8:00 a.m. – 6:00 p.m. (EST). When calling: Please know the purchase date, and the complete Saturday 8:30 a.m. – 4:30 p

Summary of the content on the page No. 12

® KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter ì KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. ITEMS KITCHENAID WILL NOT PAY FOR 1. Service ca

Summary of the content on the page No. 13

WIRING DIAGRAM SLIDE SWITCHES Slide Switches 0 1 LIGHT 0 1 MOT. 1 2 3 SPEED 1 2 3 SPEED BK TERMINAL BOX WIRING BOX BK GN W W BU 4 HALOGEN 6 HALOGEN LAMPS VERSION LAMPS VERSION 321 321 65 4 65 4 R V GY GY GY W W W 42 2 4 42 2 4 42 2 4 31 1 3 31 1 3 31 1 3 R R R R R R R R R V V V R R R V V V R R R V V V R Y BR V BU M W GY BK GN 13 R V GN R V TRANSFORMER HALOGEN LAMP R 65 4 321 V BR W BR TRANSFORMER HALOGEN BU BR GY LAMP BK W GY R V W BR BU GY BK W GY TRANSFORMER HALOGEN LAMP

Summary of the content on the page No. 14

SÉCURITÉ DOUBLURE DE HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’

Summary of the content on the page No. 15

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 16

EXIGENCES D'INSTALLATION Exigences d'emplacement Outillage et pièces IMPORTANT : Observer les dispositions de tous les codes et Rassembler les outils et pièces nécessaires avant de commencer règlements en vigueur. l'installation. Lire et respecter les instructions d’installation fournies avec chacun des outils de cette liste. Installer la hotte d'extraction à distance de toute zone exposée à des courants d'air, comme fenêtres, portes et bouches de Outillage nécessaire : chauffage. ■ Niveau Res

Summary of the content on the page No. 17

Dimensions du produit Modèle 48" (121,9 cm) 47 ¹³⁄₁₆" (121,4 cm) axe central 20 ³⁄₈" 2 ³⁄₄" (51,8 cm) (7,0 cm) 20 ¹⁄₄" (51,4 cm) 22" ¹⁵⁄₁₆" (2,4 cm) (55,9 cm) 17 ⁵⁄₁₆" dia. 7 ⁷⁄₈" (44,0 cm) (20,0 cm) 9 ³⁄₈" ⁷⁄₃₂" (5,6 mm) (23,8 cm) ³⁄₄" dia. (19,1 mm) 14 ¹⁄₈" (35,9 cm) 2" (5,1 cm) 35 ⁵⁄₈" 5 ¹⁵⁄₁₆" (90,5 cm) (15,1 cm) 43 ⁷⁄₁₆" (110,3 cm) 2 ³⁄₁₆" (5,6 cm) Modèle de 36" (91,4 cm) 35¹³⁄₁₆" axe central (91,0 cm) 9³⁄₈" 2³⁄₄" (23,8 cm) 14³⁄₁₆" (7,0 cm) (36,0 cm) ¹⁵⁄₁₆" (2,4 cm) 22" dia.

Summary of the content on the page No. 18

La sortie à l'extérieur du circuit d'évacuation peut se faire à Exigences concernant l'évacuation travers le toit ou à travers un mur. Pour la sortie à travers un mur, ■ Pour le modèle de 36" (91,4 cm), on doit utiliser un circuit on doit employer un raccord coudé à 90°. d'évacuation en conduit rond de diamètre 6" (15,2 cm). Pour le modèle de 48" (121,9 cm), on doit utiliser deux circuits mitre d'évacuation en conduit rond de diamètre 6" (15,2 cm), ou un unique circuit d'évacuation en conduit r

Summary of the content on the page No. 19

■ Un serre-câble (homologation UL ou CSA) doit être installé à chaque extrémité du câble d'alimentation. Le calibre des Spécifications électriques conducteurs (cuivre seulement) et les connexions doivent être compatibles avec la demande de courant de l'appareil IMPORTANT : La hotte doit être correctement reliée à la terre en conformité avec les codes et règlements locaux en vigueur, ou en spécifiée sur la plaque signalétique. l'absence d'un tel code, conformément aux prescriptions de la ■ La ta

Summary of the content on the page No. 20

INSTRUCTIONS D'INSTALLATION ■ Si on doit utiliser l'opercule arrachable du sommet, percer un trou de dia. 1¹⁄₄" (3 cm) dans le support de hotte à Préparation de l'emplacement l'emplacement indiqué. ■ Placer un épais matériau de protection sur le plan de travail et la table de cuisson, pour la protection contre des dommages et contre les souillures. support de la hotte 2" (5,1 cm) (vue de dessus) AVERTISSEMENT trou de montage de la hotte (côté droit/arrière) 1¹⁄₂" Risque du poids excessif (3,8 c


Alternative user manuals
# User manual Category Download
1 KitchenAid 30 User manual Ventilation Hood 4
2 KitchenAid 36"(91.4CM) ISLAND RANGE HOOD User manual Ventilation Hood 6
3 KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood User manual Ventilation Hood 4
4 KitchenAid 36 User manual Ventilation Hood 1
5 KitchenAid 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) Wall-Mount Canopy Range Hood User manual Ventilation Hood 7
6 KitchenAid 4329223 User manual Ventilation Hood 1
7 KitchenAid 4360369 User manual Ventilation Hood 1
8 KitchenAid 30" and 36" Retractable Downdraft Vent Systems User manual Ventilation Hood 7
9 KitchenAid 6899551 User manual Ventilation Hood 1
10 KitchenAid 48 User manual Ventilation Hood 1
11 KitchenAid 883297 User manual Ventilation Hood 1
12 KitchenAid 883298 User manual Ventilation Hood 2
13 KitchenAid 42 User manual Ventilation Hood 0
14 KitchenAid 6899552 User manual Ventilation Hood 1
15 KitchenAid 9763388 User manual Ventilation Hood 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0