KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front user manual

User manual for the device KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front

Device: KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front
Category: Ventilation Hood
Manufacturer: KitchenAid
Size: 0.75 MB
Added : 2/20/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front.

For your convenience

If looking through the KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KitchenAid 30" and 36" RANGE HOODwith Interchangable Style Front. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

30" (76.2 cm) and 36" (91.4 cm) RANGE HOOD
with Interchangable Style Front
Installation Instructions and Use and Care Guide
HOTTE DE CUISINIÈRE DE 30" (76,2 cm) et 36" (91,4 cm)
avec garniture de façade interchangeable
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE . . . . . . . . . . . . . .15 INSTALLATION REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . .3 EXIGENCES D’INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . .17 Outillage et pièces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Tools and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON w

Summary of the content on the page No. 4

Installation clearances Location Requirements IMPORTANT: Observe all governing codes and ordinances. ■ It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the rear wall. ■ Range hood location should be away from strong draft areas, 30" (76.2 cm) or such as windows, doors and strong heating vents. 36" (91.4 cm) min. cabinet opening width ■ Cabinet opening dimensio

Summary of the content on the page No. 5

For Best Performance: Calculating Vent System Length ■ Do not install 2 elbows together. ■ Use no more than three 90° elbows. To calculate the length of the system you need, add the ■ If an elbow is used, install it as far away as possible from the equivalent feet (meters) for each vent piece used in the system. hood’s vent motor exhaust opening. ■ Make sure there is a minimum of 24" (61 cm) of straight vent Vent piece 6" (15.2 cm) round between the elbows if more than one elbow is used. 45° elb

Summary of the content on the page No. 6

■ Check with a qualified electrician if you are not sure range ■ Wire sizes must conform to the requirements of the National hood is properly grounded. Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and ■ Do not have a fuse in the neutral or ground circuit. C22.2 No. 0-M91 (latest edition) and all local codes and ■ The range hood must be connected with copper wire only. ordinances. ■ The range hood should be connected directly to the f

Summary of the content on the page No. 7

9. Run wire through hole in accordance with the National Electrical Code or CSA Standards and local codes and WARNING ordinances. There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the Excessive Weight Hazard connection in the range hood’s electrical box. Use two or more people to move and install 10. Use caulking to seal all openings. range hood. IMPORTANT: Do not turn on power until installation is complete. Failure to do so can result in back o

Summary of the content on the page No. 8

5. Rotate the blower assembly so that the exhaust collar is facing out the back of the hood. Make Electrical Connection A WARNING B C Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. A. Exhaust blower assembly B. Screws C. Exhaust collar 1. Disconnect power at the circuit breaker of fused circuit box. 2. Connect the white wire of the power supply cable with the 6. Replace the scr

Summary of the content on the page No. 9

Optional Interchangeable Front Trim Installation Install Filters ® This hood comes standard with an Architect Series II stainless 1. For recirculating installations only, install the charcoal filters steel front trim piece. To replace the standard front trim piece with included in Recirculation Kit Part Number 4396565. Place the an optional purchased front trim piece: charcoal filter against the blower cover and rotate to the right (clockwise) to attach to cover. Repeat with other charcoal filte

Summary of the content on the page No. 10

Range Hood Use Range Hood Care The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the Range Hood Lamps cooking is complete to clear all smoke and odors from the kitchen. The range hood uses 12-volt 20-watt halogen lamps. Before you begin, make sure that the range hood is turned off and that the The hood controls are located in front on the underside of the other

Summary of the content on the page No. 11

5. Push down and twist to remove the fuse cover. Accessories 6. Replace the fuse with a new 5 amp time-delay fuse. 7. Replace the fuse cover. Optional installation kits are available from your dealer. 8. Replace the fuse holder assembly cover with the 2 screws Recirculation Kit Part Number 4396565 includes 2 charcoal filter removed earlier. packs and vent cover. 9. Reconnect power at the circuit breaker of fused circuit box. INTERCHANGEABLE FRONT TRIM PART NO. ® Cleaning Architect Series - 30” T

Summary of the content on the page No. 12

REQUESTING ASSISTANCE OR SERVICE Before calling for assistance or service, please check For further assistance “Troubleshooting.” It may save you the cost of a service call. If If you need further assistance, you can write to KitchenAid with you still need help, follow the instructions below. any questions or concerns at: When calling, please know the purchase date and the complete KitchenAid Brand Home Appliances model and serial number of your appliance. This information will Customer eXperien

Summary of the content on the page No. 13

® KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter “KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. ITEMS KITCHENAID WILL NOT PAY FOR 1. Service cal

Summary of the content on the page No. 14

WIRING DIAGRAM Slide Switches 0-1 LIGHT 0-1 MOT. SPEED 1 2 3 SLL SLM SLS 0 1 0 1 1 2 3 2-4 4-6 2-4 4-6 2-4 4-6 6-8 1-3 3-5 1-3 3-5 1-3 3-5 5-7 OR BK BR GY WIRING BOX SLL SLM SLS 24 6 24 6 24 6 8 BK Y-GN W 13 5 13 5 13 5 7 W GY 3 2 1 6 5 4 W 4 2 24 3 1 13 BK 6 5 4 3 2 1 BK DIRECTIONAL LAMPS BLOWER OHM RESISTANCE PRO MOTOR CONNECTIONS BETWEEN TERMINALS (Ω ) SPEED TO TERMINALS (SEE CONNECTIONS) 1 1-4 15.8 ±1.1 2 2-4 11.0±0.8 MOTOR GROUP 3 3-4 5.7±0.4 14 TOROIDAL TRANSFORMER Y-GN FUSE V V R R BU BK

Summary of the content on the page No. 15

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte

Summary of the content on the page No. 16

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 17

EXIGENCES D'INSTALLATION Outillage et pièces Exigences d'emplacement Rassembler les outils et pièces nécessaires avant de commencer IMPORTANT : Observer les dispositions de tous les codes et l'installation. Lire et respecter les instructions d’installation règlements en vigueur. fournies avec chacun des outils de cette liste. ■ C'est à l'installateur qu'incombe la responsabilité de respecter les distances de séparation exigées, spécifiées sur la plaque Outillage nécessaire signalétique de l'ap

Summary of the content on the page No. 18

Pour obtenir la meilleure performance Dégagements de séparation à respecter ■ Ne pas installer 2 coudes ensemble. ■ Ne pas utiliser plus de trois coudes à 90°. ■ Si un coude est utilisé, on doit le placer le plus loin possible de l'ouverture de sortie du ventilateur. ■ Veiller à incorporer une section de conduit rectiligne d’au moins 24" (61 cm) entre deux raccords coudés adjacents. ■ La longueur du système d'évacuation et le nombre de coudes largeur de l'ouverture du placard doit être réduit a

Summary of the content on the page No. 19

Calcul de la longueur effective du circuit Spécifications électriques d'évacuation IMPORTANT : Observer les dispositions de tous les codes et règlements en vigueur. Conserver les instructions d'installation Pour calculer la longueur effective du circuit d’évacuation pour consultation par l'inspecteur des installations électriques. nécessaire, additionner les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. C’est au client qu’incombe la responsabilité de con

Summary of the content on the page No. 20

INSTRUCTIONS D'INSTALLATION Options disponibles pour le circuit d’évacuation Décharge à travers le sommet du placard 1. Marquer l’emplacement où la grille de sortie sera installée au Instructions générales sommet du placard; et découper une ouverture de dia. 6"(15,2 cm) pour la grille de sortie. Installation avec décharge à l'extérieur : IMPORTANT : Ne pas terminer le conduit de décharge dans Exécuter les découpages nécessaires dans le mur pour le un espace fermé comme un grenier ou une cavité


Alternative user manuals
# User manual Category Download
1 KitchenAid User manual Blender 3
2 KitchenAid User manual Coffeemaker 9
3 KitchenAid User manual Convection Oven 330
4 KitchenAid User manual Convection Oven 15
5 KitchenAid User manual Cooktop 2
6 KitchenAid User manual Cooktop 0
7 KitchenAid User manual Dishwasher 51
8 KitchenAid User manual Dishwasher 11
9 KitchenAid User manual Frozen Dessert Maker 5
10 KitchenAid User manual Microwave Oven 1
11 KitchenAid User manual Microwave Oven 2
12 KitchenAid User manual Mixer 2
13 KitchenAid User manual Oven 1
14 KitchenAid User manual Oven 0
15 KitchenAid User manual Range 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0