Kobe Range Hoods CH0130SQB (30") user manual

User manual for the device Kobe Range Hoods CH0130SQB (30")

Device: Kobe Range Hoods CH0130SQB (30")
Category: Ventilation Hood
Manufacturer: Kobe Range Hoods
Size: 0.83 MB
Added : 3/15/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kobe Range Hoods CH0130SQB (30"). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kobe Range Hoods CH0130SQB (30").

For your convenience

If looking through the Kobe Range Hoods CH0130SQB (30") user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kobe Range Hoods CH0130SQB (30") on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kobe Range Hoods CH0130SQB (30") to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kobe Range Hoods CH0130SQB (30") User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kobe Range Hoods CH0130SQB (30") but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kobe Range Hoods CH0130SQB (30"). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



KOBE Brand Range Hood


Model No.: CH0130SQB (30'')
CH0136SQB (36'')
CH0142SQB (42'')
CH0148SQB (48'')

CH-101 SERIES – 18'' HEIGHT

INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL

Summary of the content on the page No. 2

Summary of the content on the page No. 3

- READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS.........................ERROR! BOOKMARK NOT DEFINED. COMPONENTS OF PACKAGE ................................................................................................. 3 INSTALLATION ......................................................................................................................... 4 UNDER THE CABINET INSTALLATION ...............................................................

Summary of the content on the page No. 4

IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) D

Summary of the content on the page No. 5

What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. • NEVER PICK UP A BURNING PAN – You May Get Burned. • DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. • Use an extinguisher ONLY if: a) Yo

Summary of the content on the page No. 6

COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) RANGE HOOD BOX  KOBE Range Hood – 1   Warranty Registration Card –1  Instructions Manual – 1  Baffle Filter - 2 (30”, 36”, 42”) - 3 (48”)  Stainless Steel Spacer - 0 (30”) - 1 (36”) - 2 (42”, 48”) 3/16" X 3/8" (8 pc)  Oil Tunnel – 1  Ducting Transition – 1 DUCT COVER KIT (Sold Separately)  Screw Package

Summary of the content on the page No. 7

INSTALLATION PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to Table 1. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) [(A – B) – (D + E)] D = Height of Hood E = Height of the Cabinet - FOR STAND ALONE (

Summary of the content on the page No. 8

SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Table of Contents UNDER THE CABINET INSTALLATION................................................................................6 Preparation Before Installation...................................................................

Summary of the content on the page No. 9

UNDER THE CABINET INSTALLATION Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long runs Figure 1 as possible. This may reduce the performance of the hood. • Tempo

Summary of the content on the page No. 10

Ductwork Installation 7. Use 8” aluminum or steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to seal and secure joints as shown in Figure 5. Wiring to Power Supply S AF E T Y W AR N I N G TO PREVENT THE RISK OF ELECTRICAL SHOCK OR Figure 5 INJURY, ALL RANGE HOODS SHOULD BE PROPERLY GROUNDED AND INSTALLED BY A TRAINED PROFESSIONAL WHO IS KNOWLEDGEABLE ABOUT AP

Summary of the content on the page No. 11

15. Install heating lamps (not provided), 120 Volts 175 Watts max. each. 16. Turn power ON in control panel. Check all lights and fan operation. 17. Make sure to leave this manual for the homeowner Figure 8 8

Summary of the content on the page No. 12

STAND ALONE INSTALLATION ***Follow these installations only if installing with an optional duct cover: Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 9. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long

Summary of the content on the page No. 13

2. Align hood-mounting bracket to the two screws WALL on the wall and hook hood into place. Tighten screws to secure hood to the wall. 3. For safety purpose, extra knockout holes on the back of the hood are provided for a more secure installation. Knock out as many holes as needed and secure with screws (not provided) from the inside of hood. CAUTION: MAKE SURE HOOD IS SECURE BEFORE RELEASING. Figure 13 Wiring to Power Supply SA

Summary of the content on the page No. 14

Duct Cover Installation 5. Use 8” aluminum or steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to seal and secure joints as shown in Figure 15. Slide the duct cover onto the hood. 6. Use 3/16” x 3/8” screws (provided) to attach duct cover to hood. Figure 15 Final Assembly CAUTION: Install heating lamps last. 7. Drop Oil Tunnel into suppo

Summary of the content on the page No. 15

OPERATING INSTRUCTIONS This KOBE hood is equipped with touch-sensor screen and features 3 minute delay shutoff, powerful centrifugal squirrel cage with baffle filters, bright 12-volt 20-watt halogen lights and heating lamp capability (heating lamps not included). The touch-sensor screen has Heat Lamp Control, Light Control, Speed Control (QuietMode™, Low, Medium and High), and Power Control. Refer to Figure 18. Heat Lamp Light Control Speed Control Power Control

Summary of the content on the page No. 16

Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control sign once, the symbol flashes and after 3 minutes, the hood will turn off leaving only the sign lit. Speed Control: • There are four speeds: QuietMode™, Low, Medium, and High. To activate the speed, touch the control under the speed sign. For example, if turning on hood at low speed, gently touch the symbol under the sign. If you want to switch from low to high speed, touch the symbol under the sign and

Summary of the content on the page No. 17

MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve the appearance of the hood. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hoo

Summary of the content on the page No. 18

To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.             1. Make sure all controls are off, and range hood is unplugged. 2. Place a flat-head screwdriver between light cover and housing  to remove cover . 3. Gently pull defective bulb straight out  and discard. Light bulbs should be

Summary of the content on the page No. 19

SPECIFICATIONS MODEL / SIZE CH0130SQB / 30” CH0136SQB / 36” CH0142SQB / 42” CH0148SQB / 48” DESIGN 18-Gauge Seamless Commercial Stainless Steel CONSUMPTION / AMPERE 702W / 5.85A – 30”, 36” 722W / 6.02A – 42”, 48” VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 FAN TYPE: CENTRIFUGAL Squirrel Cage EXHAUST Top Transition Rectangular to 8” Round x 1 CONTROLS Touch Sensor Screen HALOGEN LIGHTS 30” / 36” - 12V20W x 2 42” / 48” - 12V20W x 3 HEATING LAMPS 120V 175W Max. x 2 (Light Bulbs Not

Summary of the content on the page No. 20

8" (203) 2 - 1/8" (54) 1 - 7/8" (48) 1/ " (12 2 ) 1 - 1/4" (32) 6 - 1/2" (166) 4 - 1/2" (114) 1" (25) 12" (305) 24" (610) MEASUREMENTS & DIAGRAMS *** Inch measurements converted from millimeter. Inch measurements are estimated. - FOR UNDER THE CABINET - MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 17 6 - 1/2" (165) 1 - 1/4"(32) 1 " ) 1 - /4 (32 12" (306) 1 - 1/4" (32) 3 " 36 4 " / 48" 0 / " / 2 18" (457) 3 - 1/8" (79.5)


Alternative user manuals
# User manual Category Download
1 Kobe Range Hoods CH-100 CH0036SQB User manual Ventilation Hood 1
2 Kobe Range Hoods CH0130SQB User manual Ventilation Hood 0
3 Kobe Range Hoods CH0030SQB (30") User manual Ventilation Hood 0
4 Kobe Range Hoods CH-100 CH0048SQB User manual Ventilation Hood 0
5 Kobe Range Hoods CH-191 User manual Ventilation Hood 0
6 Kobe Range Hoods CH0142SQB User manual Ventilation Hood 0
7 Kobe Range Hoods CH-100 CH0042SQB User manual Ventilation Hood 0
8 Kobe Range Hoods CH0136SQB User manual Ventilation Hood 0
9 Kobe Range Hoods CH2748SQB User manual Ventilation Hood 0
10 Kobe Range Hoods CH2236SQ User manual Ventilation Hood 0
11 Kobe Range Hoods CH2230SQ User manual Ventilation Hood 0
12 Kobe Range Hoods CH2730SQB User manual Ventilation Hood 0
13 Kobe Range Hoods CH7636SQB User manual Ventilation Hood 0
14 Kobe Range Hoods CH2736SQB User manual Ventilation Hood 0
15 Kobe Range Hoods CH7630SQB User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0