Whirlpool W10240546A user manual

User manual for the device Whirlpool W10240546A

Device: Whirlpool W10240546A
Category: Ventilation Hood
Manufacturer: Whirlpool
Size: 0.48 MB
Added : 8/30/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Whirlpool W10240546A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Whirlpool W10240546A.

For your convenience

If looking through the Whirlpool W10240546A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Whirlpool W10240546A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Whirlpool W10240546A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Whirlpool W10240546A User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Whirlpool W10240546A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Whirlpool W10240546A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

30" (76.2 CM) AND 36" (91.4 CM) RANGE HOOD
Installation Instructions and Use & Care Guide
HOTTE D’ASPIRATION DE
30" (76,2 CM) ET 36" (91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTIL

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY .................................................................2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE ...............................13 INSTALLATION REQUIREMENTS ................................................3 EXIGENCES D'INSTALLATION...................................................15 Tools and Parts ............................................................................3 Outillage et pièces..........................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON when

Summary of the content on the page No. 4

Parts needed Product Dimensions For direct wire installation ■ UL listed or CSA approved ¹⁄₂" (12.5 mm) strain relief 1 ¹⁄₂" (3.8 cm) ■ 75-watt max incandescent light bulb 12" (30.5 cm) 1" 9" (2.5 cm) ■ Power supply cable (if needed, for direct wire installation) (22.9 cm) 2" For power supply cord installation (5.1 cm) ■ UL Listed Power Supply Cord Connection Kit marked for 6" range hood use. (15.2 cm) ³⁄₄" ■ 75-watt max incandescent light bulb (1.9 cm) 1 ¹⁄₂" For vented installations you

Summary of the content on the page No. 5

Venting Requirements (Vented Models Only) ■ Vent system must terminate to the outdoors, except for non- Roof Venting Wall Venting vented (recirculating) installations. ■ Do not terminate the vent system in an attic or other enclosed area. A D ■ Do not used a 4" (10.2 cm) laundry-type wall cap. A ■ Use a 7" (17.8 cm) round metal vent or a 3¹⁄₄" x 10" B B (8.3 x 25.4 cm) rectangular metal vent. Rigid metal vent is D recommended. Plastic or metal foil vent is not recommended. ■ The length of vent

Summary of the content on the page No. 6

Example vent system Electrical Requirements Wall cap 90˚ elbow Observe all governing codes and ordinances. 6 ft (1.8 m) Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 2 ft (0.6 m) and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified el

Summary of the content on the page No. 7

INSTALLATION INSTRUCTIONS Prepare Location NOTE: For vented installations, it is recommended that the vent system be installed before hood is installed. Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent. 1. For vented installations, determine which venting method to 2" (5.1 cm) use: roof or wall. 7 ¹⁄₂" from wall, (19 cm) not cabinet 2. Select a flat surface for assembling the range hood. Place frame covering over that surface. Centerline

Summary of the content on the page No. 8

Wall Venting Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm) To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall: Rectangular Vent to 7" (17.8 cm) Round Vent Transition 1. Make 2 lines by measuring from floor 65⁷⁄₈" (167.3 cm) and 62³⁄₈" (158.4 cm) or ¹⁄₈" (3.2 mm) and 3⁵⁄₈" (9.2 cm) down from Roof Venting underside of cabinet and mark on the centerline on the back To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the wall. underside of cabinet bottom: 2. Mark lines

Summary of the content on the page No. 9

Install Range Hood 1. Remove terminal box cover. Depending on your installation, 5. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown. remove either back or top wiring knockout. A A A. Drill pilot hole 6. Install the 4 - #10 x ⁵⁄₈" mounting screws in pilot holes. Leave about ¹⁄₄" (6.4 cm) space between screw heads and cabinet to slide range hood into place. A. Terminal box cover 2. Remove the rectangular and round vent connectors from ¹⁄₄" hood. Set the connectors and screws aside fo

Summary of the content on the page No. 10

Make Electrical Connection Complete Installation Install 75-watt (max.) incandescent light bulb WARNING 1. Squeeze the plastic lens cover and remove it from the hood. B A Fire Hazard Electrically ground the blower. Use copper wire. A. Light bulb socket Connect ground wire to green ground screw in B. Lens cover terminal box. 2. Screw light bulb into socket. Failure to do so can result in death, fire, or 3. Replace lens cover by squeezing cover and inserting tabs electrical shock. into slots.

Summary of the content on the page No. 11

Range Hood Controls ASSISTANCE OR SERVICE Operating the Light When calling for assistance or service, please know the purchase date and the complete model and serial number of your The LIGHT control is shown in the off position. For maximum appliance. This information will help us to better respond to your lighting, rotate the control clockwise 45°. Rotate the control request. clockwise another 45° for minimum lighting. If you need replacement parts If you need to order replacement parts, we

Summary of the content on the page No. 12

WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. This limited warranty is valid o

Summary of the content on the page No. 13

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alert

Summary of the content on the page No. 14

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 15

EXIGENCES D'INSTALLATION ■ Quatre vis à bois ou vis à métaux à tête plate avec rondelles et écrous, pour la fixation des tringles d'appui. Outillage et pièces Rassembler les outils et pièces nécessaires avant de commencer l'installation. Lire et suivre les instructions fournies avec les outils Exigences d'emplacement indiqués ici. IMPORTANT : Observer les dispositions de tous les codes et Outils nécessaires règlements en vigueur. ■ Perceuse ■ C'est à l'installateur qu'incombe la responsabili

Summary of the content on the page No. 16

■ Au niveau de chaque jointure du conduit de décharge, Dégagements de séparation à respecter assurer l'étanchéité avec les brides de serrage pour conduit. ■ Le système d'évacuation doit comporter un clapet. Si la bouche de décharge murale ou par le toit comporte un clapet, ne pas utiliser le clapet fourni avec la hotte de cuisinière. ■ Autour de la bouche de décharge à l'extérieur, assurer l'étanchéité avec un produit de calfeutrage. largeur ouverture du placard Installations pour régions à

Summary of the content on the page No. 17

Système de décharge de 3¹⁄₄" x 10" (8,3 cm x 25,4 cm) Calcul de la longueur effective du circuit d'évacuation Composant Pour calculer la longueur effective du circuit d'évacuation Coude à 90° de 3¹⁄₄" x 10" 5 pi (1,5 m) nécessaire, additionner les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. (8,3 cm x 25,4 cm) Système de décharge de 7" (17,8 cm) Composant Conduit de diamètre 7" (17,8 cm) Coude plat de 3¹⁄₄" x 10" 12 pi (8,3 cm x 25,4 cm) (3,7 m) C

Summary of the content on the page No. 18

■ Si le domicile est équipé d'un câblage en aluminium, suivre ■ Le calibre des conducteurs et les connexions doivent être les instructions suivantes : compatibles avec la demande de courant de l'appareil spécifiée sur la plaque signalétique. La plaque signalétique 1. Connecter une section de câble en cuivre massif aux de l'appareil est située derrière le filtre, sur la paroi arrière de conducteurs en queue de cochon. la hotte. 2. Connecter le câblage en aluminium à la section ajoutée de câ

Summary of the content on the page No. 19

3. Tracer un cercle en utilisant un compas ou un gabarit Style 1 - Découpage d'ouverture pour un système circulaire de 7¼" (18,4 cm). d'évacuation rectangulaire de 3¼" x 10" (8,3 cm x 4. Utiliser une scie sauteuse ou une scie à guichet pour 25,4 cm) découper une ouverture de 7¼" (18,4 cm) de diamètre. 5. Répéter les étapes 1 à 4 pour la paroi inférieure du sommet Décharge à travers le toit du placard. Découpage d'une ouverture rectangulaire de 4" x 10½" (10,2 cm x 26,7 cm) dans le fond et l

Summary of the content on the page No. 20

4. Utiliser une scie sauteuse ou une scie à guichet pour ■ Réinstaller le connecteur de conduit rond. découper une ouverture de 7¼" (18,4 cm) de diamètre. REMARQUE : Si la bouche de décharge murale est située directement derrière le connecteur de conduit, on doit veiller 7 ¹/₄" (18,4 cm) diam. à empêcher toute interférence entre les clapets du connecteur et de la bouche de décharge murale. En cas d'interférence, supprimer le clapet du connecteur de conduit. Installations sans décharge à l'ex


Alternative user manuals
# User manual Category Download
1 Whirlpool 30 User manual Ventilation Hood 26
2 Whirlpool 35-718 User manual Ventilation Hood 7
3 Whirlpool 29-718 User manual Ventilation Hood 0
4 Whirlpool 4.32E+13 User manual Ventilation Hood 2
5 Whirlpool 24" (58 CM) User manual Ventilation Hood 3
6 Whirlpool 36" User manual Ventilation Hood 1
7 Whirlpool 9763375 User manual Ventilation Hood 1
8 Whirlpool 99044504A User manual Ventilation Hood 0
9 Whirlpool 48" User manual Ventilation Hood 2
10 Whirlpool 99044505A User manual Ventilation Hood 0
11 Whirlpool 761883306 User manual Ventilation Hood 0
12 Whirlpool 9760266 User manual Ventilation Hood 0
13 Whirlpool GZ5730 User manual Ventilation Hood 0
14 Whirlpool GZ5730XRB1 User manual Ventilation Hood 0
15 Whirlpool GZ5730XR User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0