Zephyr ALL-M90ABX user manual

User manual for the device Zephyr ALL-M90ABX

Device: Zephyr ALL-M90ABX
Category: Ventilation Hood
Manufacturer: Zephyr
Size: 2.41 MB
Added : 6/14/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Zephyr ALL-M90ABX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Zephyr ALL-M90ABX.

For your convenience

If looking through the Zephyr ALL-M90ABX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Zephyr ALL-M90ABX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Zephyr ALL-M90ABX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Zephyr ALL-M90ABX User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Zephyr ALL-M90ABX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Zephyr ALL-M90ABX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.zephyronline.com
Duo Is.
ADL-M90ASX
ADL-E42ASX
Layers Is.
ALL-M90ABX
ALL-M90AWX
ALL-E42AWX
ALL-E42ABX
RANGE HOOD - Installation instructions

Summary of the content on the page No. 2

www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 25 CAMPANA EXTRACTORA - Manual de utilización...Pag. 48 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 73 - 2 -

Summary of the content on the page No. 3

SAFETY INSTRUCTIONS..................................................................................................pag. 4 LIST OF MATERIALS...........................................................................................................pag. 7 DUCTING CALCULATION SHEETS...............................................................................pag. 9 HOOD SPECIFICATION..................................................................................................pag. 10 INSTALLAT

Summary of the content on the page No. 4

www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents. Suitable for use in household cooking area WARNING - To reduce the

Summary of the content on the page No. 5

settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, fi lters and grease laden surface clean. F. Use high range setting on range only when necessary.Heat oil slowly on low to medium settin

Summary of the content on the page No. 6

www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducte

Summary of the content on the page No. 7

Models: ADL-M90ASX / ADL-E42ASX Duct Covers Support Frame Assembly Blower Housing Control Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A 1/8" x 1/4" 28 B 1/4" x 2-3/4" 4 C - 7 - List of Materials

Summary of the content on the page No. 8

www.zephyronline.com Models: ALL-M90ABX / ALL-M90AWX / ALL-E42AWX / ALL-E42ABX Duct Covers Support Frame Assembly Glass Blower Housing Control Range Hood Body Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A 1/8" x 1/4" 28 B 1/4" x 2-3/4" 4 C - 8 - List of Materials

Summary of the content on the page No. 9

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 9 - Ducting Calculation Sheet

Summary of the content on the page No. 10

www.zephyronline.com Models: ADL-M90ASX / ADL-E42ASX front of hood side of hood top of hood         - 10 - Hood Specifi cations   

Summary of the content on the page No. 11

Models: ALL-M90ABX / ALL-M90AWX / ALL-E42AWX / ALL-E42ABX front of hood side of hood top of hood - 11 - Hood Specifi cations

Summary of the content on the page No. 12

www.zephyronline.com The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and in-line blower preparation please turn to page 14. 1. Remove the (7) screws securing the remote motor support bracket to the motor housing and then remove the bracket. See Fig.1 2. Insert the 6” sheet metal fl ange in the motor a

Summary of the content on the page No. 13

6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex con- nector located inside the blower housing. See Fig.6 7. Install the motor and bracket, inside the motor housing, completing the installation using the other screws (6 type B )that have been sup- plied. (Tot. 13 type B). Fig. 7 8. Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire. See Fig.8 WARNING! Place electrical wiring inside the blower hou- si

Summary of the content on the page No. 14

www.zephyronline.com The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 12. 1. Break out the partially pre- cut circle in the lid, located on the remote motor sup- port bracket, using a fl at head screwdriver. Fig. 1 2. Remove the cover

Summary of the content on the page No. 15

Note1: A cable lock (not included) may be re- quired by local codes. Please review local co- des for more information. 6. Reinstall the cover on the motor housing by following the instructions from step 2 in re- verse order. 7. Attach 6 pin male molex connectors to 6 pin female molex connectors inside blower hou- sing. See Fig. 6 Note2: Check local codes to determine mini- mum wire gauge. See manual included with external and in- line blower for instructions on installing the blower. - 15 -

Summary of the content on the page No. 16

www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/certifi ed Silver Tape or Duct Tape. Some Ducting Options - 16 - Installation - Ducting Options

Summary of the content on the page No. 17

MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking surface. If a connecting duct work composed of   two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to  the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions remove the decorative mesh fi lters so that the range hood is easier to handle. 

Summary of the content on the page No. 18

www.zephyronline.com into the attic to connect after the hood is installed. Fig.11 3. Place assembled support frames on top of hood and secure it to the hood body using 8 type B screws. Fig.12 4. Place duct covers over assembled support frame until they rest on the hood body. Fig.13 Note! If you ordered a wood trim piece or re- circulating kit please refer to the instructions included inside the kits prior to installing the hood to the ceiling. - 18 - Installation - Mounting the Range

Summary of the content on the page No. 19

5. Position hole template on the ceiling paying at- tention that the arrow is positioned on the same side as the range hood controls. - Make 4, holes in the ceiling and drive in (3 type C) screws without completely tightening them. Pay attention not to insert the screw into the hole marked with an X on the hole template Fig.14 6. Lift the hood assembly to the ceiling and align the top support frame with the (3) screws previously installed in the ceiling. - Rotate assembly slightly c

Summary of the content on the page No. 20

www.zephyronline.com GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Temporarily join the two duct covers by lifting the bottom one and then carefully securing it to the top by using adhesive tape. Fig. 17. Take care not to scratch the duct covers. 2. Break out the partially


Alternative user manuals
# User manual Category Download
1 Zephyr AK11005 User manual Ventilation Hood 2
2 Zephyr AK7500ASX User manual Ventilation Hood 0
3 Zephyr AK7548ASX User manual Ventilation Hood 0
4 Zephyr AK11245 User manual Ventilation Hood 1
5 Zephyr AK8100AS User manual Ventilation Hood 1
6 Zephyr AK11365 User manual Ventilation Hood 0
7 Zephyr AK8100S User manual Ventilation Hood 0
8 Zephyr AK7536ASX User manual Ventilation Hood 1
9 Zephyr AK8000AS User manual Ventilation Hood 1
10 Zephyr AK8200AS User manual Ventilation Hood 2
11 Zephyr AK8300ASX User manual Ventilation Hood 1
12 Zephyr ALL-E42ABX User manual Ventilation Hood 0
13 Zephyr ALL-E42AW X User manual Ventilation Hood 0
14 Zephyr APN-M90ABX User manual Ventilation Hood 2
15 Zephyr ARC AHZ-M90AWX User manual Ventilation Hood 3
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0