Emerson Hot1 user manual

User manual for the device Emerson Hot1

Device: Emerson Hot1
Category: Water Dispenser
Manufacturer: Emerson
Size: 3.03 MB
Added : 1/27/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson Hot1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson Hot1.

For your convenience

If looking through the Emerson Hot1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson Hot1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson Hot1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson Hot1 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson Hot1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson Hot1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Model Hot1
Instant Hot Water Dispenser
Owner’s Manual
Installation, Care & Use
Instalacion, cuidado & uso
Installation, soin et utilisation

Summary of the content on the page No. 2

WHAT YOU SHOULD KNOW BEFORE YOU BEGIN   For your satisfaction and safety, read all instructions, cautions, warnings and dangers before installing or using this instant hot water dispenser.   This particular unit is not intended for commercial use.   Make sure that all electrical wiring and connections conform to local codes.   A standard 115-volt grounded electrical outlet is required under the sink for the dispenser’s electrical power.   The wall outlet powering your dispenser must

Summary of the content on the page No. 3

HOW TO USE THIS INSTRUCTION MANUAL These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process. What you’ll see in the B Press valve lever down for about 20 Valve instruction manual: seconds until water freely runs out of Lever the spout. Hold valve open at lease 60 seconds to

Summary of the content on the page No. 4

DIMENSIONS 2½" (6.4cm) 4" (10.2cm) Spout Spout Holder Valve Maximum Lever 6" Countertop (15.2cm) Thickness Mounting for Mounting Nut Rubber 2" (5.1cm) Gasket 3" Slotted (7.6cm) Set Screw (Opposite Side) Wing Nut Width of Unit 5¼" (13.3cm) 11¾ 8" (28.9cm) ¼" Copper Tube 16" Long (40.6cm) 3 Wire Power Cord 9 30" Long 2¼ " 16 (76cm) Cold Water Line (6.5cm) 4

Summary of the content on the page No. 5

START HERE PREPARATION 1   Identify location for the dispenser. A Required minimum from   Check to make sure there is proper center of hole to wall clearance for dispenser handle to be 3 3 ⁄4" fully opened.   Check to make sure counter is not Maximum counter too thick. thickness (depth)   Make sure there is a grounded 2" electrical outlet under the sink. The wall outlet for your dispenser must have power supplied to it continuously and must be fused. It should not be controlled by the

Summary of the content on the page No. 6

INSTALLING THE DISPENSER 2   Remove the spout by loosening A the set screw in spout holder approximately 2 full turns and pull out spout.   Mount the unit through the 1 3/8" diameter (35 mm) hole in the sink. Make sure the valve lever is in the up position and feed the spout end of the dispenser through the sink mounting hole. Mounting   While holding the dispenser in  B Nut place with spout removed, slip the rubber gasket and mounting Rubber nut over the valve lever and Gasket hand

Summary of the content on the page No. 7

WATER CONNECTION OPTIONS 3 Compression valve or T-fitting option (not supplied):   Ensure that a shutoff valve is installed T-fitting 1/4" Diameter on the cold water supply line. If so, a Tube T-fitting or compression valve can be Cold Water used to connect the dispenser. Supply Line   Connect the 16" (40.6 cm) long, 1/4" diameter copper tube on the dispenser to the T-fitting as shown (see step 4). Saddle valve option (not supplied):   Follow the directions for “self-piercing attachment”

Summary of the content on the page No. 8

CONNECTING WATER TO DISPENSER 4   Bend and position the 1/4" copper A line from the dispenser so it fits into the cold water supply. With one hand, support the copper line coming out of the tank and bend the tube with the other hand.   Do not kink. Bend tube carefully. Property Damage: Make sure the bends in tubing are smooth and not kinked. Don’t use paste-type sealants on water line connections. Tighten compression fittings snug but don’t over tighten.   When connecting to a compression

Summary of the content on the page No. 9

FILL THE TANK & CONNECT POWER 5   First, open the shutoff valve all the A way and see if your connections are watertight. If there are any leaks carefully re-tighten all connections. Property Damage: Never place a restriction on the delivery of water from the spout. Such a restriction prevents draining the expansion chamber and could damage the tank.   Press valve lever down for about 20 B Valve seconds until water freely runs out of Lever the spout. Hold valve open at least 60 seconds to le

Summary of the content on the page No. 10

Electric Shock Hazard: Using an ungrounded or improperly connected appliance can result in serious injury or death from electrical shock. This appliance must be grounded. This instant hot water dispenser is equipped with a cord that has a grounding conductor and a grounding pin. The plug must be connected to an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided with the appliance – if it will not fit the o

Summary of the content on the page No. 11

CARE AND USE PROPERTY DAMAGE Electric Shock Hazard: To prevent electrical shock,   Regularly inspect the unit for any signs of disconnect power before servicing unit. Use only a leakage. If there are signs of water damage, properly grounded and polarized electric outlet. immediately remove the unit from service.   To avoid water damage from leakage, ADJUSTING THE THERMOSTAT replace all cut, loose or split tubing. Factory temperature   A drain pan, plumbed to an appropriate pre-set is 190˚

Summary of the content on the page No. 12

Please read Troubleshooting Guide and/or visit ™ www.insinkerator.com before calling AnswerLine TROUBLESHOOTING PROBLEM POSSIBLE CAUSE WHAT TO DO Water and steam spits • Unit is boiling. • Depress faucet lever to release some water from forcefully from spout the tank. May be normal during initial setup. without turning on the • Adjust water temperature using dial on tank front. dispenser faucet. Remember that at higher altitudes, water boils at lower temperatures. Water is not hot • The unit

Summary of the content on the page No. 13

Modelo Hot1 Dispensador de agua caliente instantánea Manual del usuario Instalacion, cuidado & uso Installation, Care & Use Installation, soin et utilisation

Summary of the content on the page No. 14

LO QUE DEBERÍA SABER ANTES DE COMENZAR   Para su satisfacción y seguridad, lea todas las instrucciones, precauciones, advertencias y peligros antes de instalar o usar este surtidor de agua caliente al instante.   Esta unidad en particular no está diseñada para uso comercial.   Asegúrese de que todas las conexiones y cableados eléctricos cumplan con los códigos locales.   Se requiere un tomacorriente conectado a tierra estándar de 115 voltios bajo el fregadero para suministrar energía

Summary of the content on the page No. 15

CÓMO USAR ESTE MANUAL DE INSTRUCCIONES Estas instrucciones están separadas en secciones principales, indicadas con números y subsecciones indicadas con letras mayúsculas. El manual está organizado de este modo para que pueda tomar un descanso en cualquier momento después de concluir una sección o subsección sin afectar el proceso de instalación. Lo que usted verá en el manual de instrucciones: 2 1 3 Proporciona una narración paso a paso que describe el paso de instalación, con 1 casillas de c

Summary of the content on the page No. 16

DIMENSIONES 16

Summary of the content on the page No. 17

INICIE AQUÍ PREPARACIÓN 1   Identificar la ubicación para el surtidor. A Mínimo requerido a partir del   Verificar para asegurarse que haya el centro del orificio hasta la pared espacio libre adecuado para que la 3 3 ⁄4" (9.5 cm) manija del surtidor abra completamente.   Verificar para asegurarse que la Grosor máximo de la cubierta cubierta no sea demasiado delgada. (profundidad)   Asegurarse que haya bajo el fregadero 2" (5 cm) un tomacorriente eléctrico con conexión a tierra. El toma

Summary of the content on the page No. 18

INSTALACIÓN DEL SURTIDOR 2   Quite el tubo surtidor de agua A aflojando el tornillo de ajuste en el porta-tubo surtidor, aproximadamente 2 vueltas completas y tire del tubo surtidor.   Monte la unidad a través del orificio de 1 3/8" de diámetro (35 mm) en el fregadero. Asegúrese de que la palanca de válvula esté en la posición vertical y pase el extremo del tubo surtidor de agua a través del orificio de montaje del fregadero.   Mientras sujeta el surtidor en su  B sitio con el tubo surtid

Summary of the content on the page No. 19

OPCIONES DE CONEXIÓN DE AGUA 3 Opción de válvula de compresión o conector en T (no incluido):   Si la línea de agua fría de su grifo ya tiene una válvula de cierre, se podría agregar un conector en T o una válvula de compresión para dar abasto al surtidor de agua caliente al instante.   Conecte el tubo de cobre de 16" (40.6 cm) de largo y 1/4" (6.3 mm) diámetro del surtidor al conector en T, tal como se muestra (Véase el Paso 4). Opción de válvula de asiento (no incluida):   Siga las sig

Summary of the content on the page No. 20

CONEXIÓN DE AGUA AL SURTIDOR 4   Doble y coloque la línea de cobre de A 1/4" del surtidor de modo que se ajuste al suministro de agua fría. Con una mano, sostenga la línea de cobre que proviene del tanque y doble el tubo con la otra mano.   No haga torcimientos. Doble el tubo con sumo cuidado. Daño a la propiedad: Asegúrese que los dobleces en la tubería sean tenues y no haya retorcidos. No use selladores tipo pasta en las conexiones de la línea de agua. Apriete las conexiones de compresión


Alternative user manuals
# User manual Category Download
1 Emerson Instant Hot User manual Water Dispenser 1
2 Emerson UW User manual Water Dispenser 0
3 Emerson UWL User manual Water Dispenser 1
4 Emerson TranScape H-View-SS User manual Water Dispenser 2
5 Edelbrock 2475 User manual Water Dispenser 0
6 Sony 2 User manual Water Dispenser 3
7 ADTX User manual Water Dispenser 4
8 Agilent Technologies E4408B User manual Water Dispenser 16
9 AEG PWE9039M User manual Water Dispenser 15
10 Agilent Technologies 8156A User manual Water Dispenser 7
11 Agilent Technologies 8591E User manual Water Dispenser 7
12 Agilent Technologies 8596E User manual Water Dispenser 5
13 Agilent Technologies 8594E User manual Water Dispenser 13
14 Agilent Technologies 8593E User manual Water Dispenser 13
15 Agilent Technologies 856290216 User manual Water Dispenser 1