Summary of the content on the page No. 1
®
Invacare Lifts and Slings
• Battery Powered and Hydraulic Lifts
• Stand-Up and Heavy-Duty Lifts
• Full Assortment of Slings
Summary of the content on the page No. 2
® ™ Invacare Reliant 450 Lifts ® ™ Invacare Reliant 450 Lifts ® ™ The Invacare line of Reliant lifts was conceived to help reduce the possibility of caregiver back injury and to ensure dignity in patient handling. These high-quality lifts are comfortable, reliable and integral tools for staff and caregivers. Using the lift for patient handling can help reduce staff injuries, save you money and reinforce safety as a priority in your health care facility. Invacare Reliant lifts support up to 450 p
Summary of the content on the page No. 3
® ™ Invacare Reliant 450 Lifts ® ™ Invacare Reliant 450 Lifts Reliant Lift Features • Height range allows lifting from floor and high surfaces • Multi-grip push handle is angled to minimize wrist strain • Low friction casters significantly improve rollability and contribute • Base legs adjust easily and lock securely into open position with the to caregiver safety padded shifter handle or optional power option • Removable battery pack eliminates downtime and simplifies the • Total pinch-point pr
Summary of the content on the page No. 4
® ™ Invacare Reliant 450 Lifts ® ™ Invacare Reliant 450 Lifts Lift Specifications Hydraulic Power Hydraulic Power Power Lift w/ Power Adjustable Adjustable Low Base Low Base Opening Base RHA450-1 RPA450-1 RHL450-1 RPL450-1 RPL450-2 Height Maximum at sling hook-up 73" 76" 71" 74" 74" Minimum at sling hook-up 27" 26" 25" 24" 24" Base height (clearance) 6.8" 6.8" 4.5" 4.5" 4.5" Base width Open 41" 41" 41" 41" 41" Closed 26.5" 26.5" 26.5" 26.5" 26.5" Base length 48" 48" 48" 48" 48" Casters Front 5"
Summary of the content on the page No. 5
® ™ Invacare Get-U-Up Hydraulic Stand-Up Lift ® ™ Invacare Get-U-Up Hydraulic Stand-Up Lift ® ™ Comfortable and secure, the Invacare Get-U-Up stand-up lift is the answer to your patient transfer needs. Its ergonomic styling and easy maneuverability make the Get-U-Up an ideal product for every day patient handling. The Get-U-Up helps ensure caregiver security and patient peace of mind. Ideal for use with partial weight-bearing patients as well as those needing rehabilitation support, the Invacare
Summary of the content on the page No. 6
® ™ Invacare Reliant 350 Stand-Up Lift ® ™ Invacare Reliant 350 Stand-Up Lift Comfortable and secure, the Invacare Reliant 350 Stand-Up lift is the answer to your patient handling needs. Its ergonomic styling and easy maneuverability make the Reliant 350 an ideal product for everyday patient handling. With its numerous safety features, the Reliant 350 Stand- Up lift helps ensure caregiver security and resident peace of mind. Ideal for use with weight- bearing or fully dependent patients as well
Summary of the content on the page No. 7
® ™ Invacare Reliant 350 Stand-Up Lift ® ™ Invacare Reliant 350 Stand-Up Lift Specifications Pwr. Base Model no. RPS350-1 RPS350-2 Height Maximum at sling hook-up 63.7" 63.7" Minimum at sling hook-up 39.6" 39.6" Base height (clearance) 4.5" 4.5" Base width Open 36.8" 35.8" Closed 25.7" 25.7" Base length 35.5" 35.5" Casters Front 3" 3" Rear (locking) 5" 5" Weight capacity 350 lb. 350 lb. Product weight Out of carton 115 lb. 118 lb. Shipping 125 lb. 128 lb. Model no. RPS350-2 Stand-Up Lift Model n
Summary of the content on the page No. 8
® ™ Invacare Reliant 440 Stand-Up Lift ® ™ Invacare Reliant 440 Stand-Up Lift ® ™ Comfortable and secure, the Invacare Reliant 440 Stand-Up lift is the answer to your patient handling needs. The ergonomic styling and easy maneuverability make the Reliant 440 an ideal product for everyday patient transfers. With its numerous safety features, the Reliant 440 Stand-Up Lift helps ensure caregiver security and resident peace of mind. Ideal for use with weight-bearing of fully dependent patients, as w
Summary of the content on the page No. 9
® ™ Invacare Reliant 440 Stand-Up Lift ® ™ Invacare Reliant 440 Stand-Up Lift Specifications Model no. RPS440-1 Height Maximum at sling hook-up 67" Minimum at sling hook-up 39" Base height (clearance) 5" Base width Open 44" Closed 26" Base length 41.5" Casters Front 4" Rear (locking) 4" Weight capacity 440 lb. Product weight Out of carton 117 lb. Shipping 167 lb. Model RPS440-1 with WT200 Walking Tutor Attachment (Optional) Model no. R131 Extra-large standing sling Electronics • Removable batter
Summary of the content on the page No. 10
® ™ Invacare Reliant 600 Heavy-Duty Lift ® ™ Invacare Reliant 600 Heavy-Duty Lift Designed to meet the special needs of your patients weighing up to 600 pounds, ® ™ the Invacare Reliant 600 heavy-duty lift is secure and sturdy, providing a safe alternative to manual lifting. Both durable and functional, the Reliant 600 is also a reassuring and comfortable patient lift. When answering the needs of every patient is your priority, this is your wisest choice. Model no. RPL600-1 Power lift with low b
Summary of the content on the page No. 11
® ™ Invacare Reliant 600 Heavy-Duty Lift ® ™ Invacare Reliant 600 Heavy-Duty Lift ® ™ Invacare Reliant Digital Scale Charging Station Manual Lowering Model no. RLS6 • Manual emergency lowering • One 24-volt battery on mast with • Precision scale mounted on swivel bar quick release feature gently and safely lowers accurately measures weights up to resident in case of total power • Battery can be replaced 600 lb. loss immediately with second battery ™ • Retrofits on all Reliant 450/600 lifts. in w
Summary of the content on the page No. 12
® ™ Invacare Reliant Slings ® ™ Invacare Reliant Slings For Reliant 450 Lifts & Model No. 9805 Lifts ® ™ Invacare Reliant slings come in a wide array of styles to meet a variety of client needs, and the new, improved overall design makes them all easier than ever to position. Reliant slings feature a unique, fully padded fabric that forms a soft yet supportive surface. The soft, brushed lining helps prevent sliding for ultimate comfort and skin protection, and the new, stretch-resistant feature
Summary of the content on the page No. 13
® ™ Invacare Reliant Slings ® ™ Invacare Reliant Slings For Reliant 450 Lifts & Model No. 9805 Lifts Sling Binding Colors Refer to chart below. Sling Sizes Note: Sling size and fit can vary Color / Weight Chart significantly depending on patient weight and girth. These are general guidelines. 600 Consult physician before sling selection. 500 Washing instructions are on each sling label. Washing temperature should not 400 exceed 180˚F. Air-dry or dry at low temperatures. 300 All slings are constr
Summary of the content on the page No. 14
® Invacare 9805 and 9805P Hydraulic Lifts ® Invacare 9805 and 9805P Hydraulic Lifts Too often, manual patient transfers lead to caregiver back injuries. The Invacare 9805 and 9805P hydraulic lifts were created to make handling situations safer and affordable for everyone involved. With their slim design, these hydraulic lifts are versatile enough to use for most any and all patient transfers. The features of the 9805 and 9805P include a padded swivel bar and push handle, a 450-pound weight capac
Summary of the content on the page No. 15
® Invacare 9805 and 9805P Hydraulic Lifts ® Invacare 9805 and 9805P Hydraulic Lifts Base Model no. 9884 Adjustable base • Completely enclosed cam moves legs of adjustable base Hydraulic pump rises from lowest to highest boom height with minimal • Offers obstruction-free operation; ideal for cleaning physical effort. • Screw-in pin at mast base provides maximum stability and prevents removal of mast Standard sling Standard Slings Model no. Chain or Strap Assembly Kit (required for standard slings
Summary of the content on the page No. 16
® Invacare Lifts and Slings Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio 44035-4190 (800) 333-6900 Canada 570 Matheson Blvd. E. Unit 8 Mississauga, Ontario L4Z 4G4 Canada (800) 668-5324 © 2008 Invacare Corporation. All rights reserved. Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporation unless other- wise noted. 00-266 Rev. 02/08