Oregon BPW128 user manual

User manual for the device Oregon BPW128

Device: Oregon BPW128
Category: Blood Pressure Monitor
Manufacturer: Oregon
Size: 0.51 MB
Added : 7/24/2013
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Oregon BPW128. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Oregon BPW128.

For your convenience

If looking through the Oregon BPW128 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Oregon BPW128 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Oregon BPW128 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Oregon BPW128 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Oregon BPW128 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Oregon BPW128. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1
LOG BOOK
: Age: Weight: kg/lbs
2 21.2 22.2
10:05 10:12
mmHg
220
200
180
160
x
x
140
120
x
x
100
x
x
80
60
/ min 85 90
158 155
92 93
110 112
1
GB

Summary of the content on the page No. 2

GB LEGEND : - FAST INCREMENT - FLASHING BOLD - PRESS BUTTON BOLD - PRESS AND HOLD BUTTON F LEGENDE : - AUGMENTATON RAPIDE - CLIGNOTEMENT - APPUYER SUR LE BOUTON BOLD BOLD - APPUYER SANS LACHER SUR LE BOUTON ES LEYENDA : - INCREMENTO RÁPIDO - DESTELLANDO BOLD - PULSAR BOTÓN BOLD - PULSAR MANTENER OPRIMIDO EL BOTÓN 2 GB

Summary of the content on the page No. 3

WRIST TYPE BLOOD PRESSURE INFORMATION CONCERNING THE CE MONITOR SYMBOL This device complies with the European regulations based on the MODEL: BPW128 Medical Products Code, and bears the CE mark “CE0123”. The device has been quality inspected according to EG guideline USER’S MANUAL 93/42/EWG and tested in compliance to the EN1060-1 Non-invasive sphygmomanometers-Part 1, General requirements and EN1060-3 Non-invasive sphygmomanometers-Part 3: INTRODUCTION Supplementary requirements for electrome

Summary of the content on the page No. 4

DESCRIPTION AND FUNCTION OF PARTS F A A. Liquid Crystal Display (LCD) and protective cover - Large easy-reading display - 5 functional symbols E - Systolic [SYS/mmHg], Diastolic [DIA/mmHg], Mean [MAP/mmHg], Pulse [pul/min.]and date & time display. C B. Battery compartment D Houses two (2) LR03 /AAA/ UM4 size 1.5V batteries C. Button - For time adjustment. B D. Button - Activates and deactivates the unit and initiates pressure measuement process. ▲ ▲ E. / ▲ ▲ ▲ Button - Recall memory or increa

Summary of the content on the page No. 5

AAA AAA DISPLAY-SYMBOL DESCRIPTION INSTALLING BATTERIES 1. Slide battery cover off. 2. Install batteries first. Ensure Symbol Description Explanation correct polarity. Battery Type: 2 Alkaline LR03 (AAA)size Appears when Memory Mark measurement value is 3. Replace the cover. recalled from memory Replace the batteries if: 1. the weak battery mark appears Appears when batteries Weak Battery should be replaced in the display 2. nothing appears in the display when the power is switched on. Appears

Summary of the content on the page No. 6

PROPER EQUIPMENT SETUP 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accurate measurements, fasten the velcro strap securely around your wrist so there is no extra space between the cuff and the wrist. If the cuff is not wrapped

Summary of the content on the page No. 7

BLOOD PRESURE DEFINITIONS WHAT IS MEAN ARTERIAL PRESSURE (MAP) Information obtained from the World Health Organization (WHO) The Mean Arterial Pressure is the average pressure forcing blood through the arteries. It is not the average of the systolic and diastolic Hypertension systolic over 160 blood pressure. It corresponds to a state of balance between the (high pressure) diastolic over 95 compressive and expansive forces acting on the arterial wall when 95 there is no distension of the arteria

Summary of the content on the page No. 8

MEASUREMENT With the individual in a sitting position and with the cuff attached as previously mentioned, a blood pressure reading can be obtained. Note: - For accurate pressure measurement, take blood-pressure readings in a seated position. Avoid leaning back while the measurement is being taken. - Ensure that the lower arm is raised so that the upper edge of the cuff is on the same level as the heart. - Ideally, place the palm of the hand facing upwards. - In order to ensure a proper measureme

Summary of the content on the page No. 9

HOW TO TAKE MEASUREMENT Refer to Fig1 Fig1 2sec Fig1 9 GB

Summary of the content on the page No. 10

Note: 1. Remove all watches, jewelry, etc. prior to attaching the wrist 2sec monitor. Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accurate measurements, fasten the velcro strap securely around your wrist so there is no extra space between the cuff and the wrist. If the cuff is not wrapped tight enough,

Summary of the content on the page No. 11

HOW TO SET THE TIME Refer to Fig3 mode Fig 3 11 GB

Summary of the content on the page No. 12

Note: AUTOMATIC POWER OFF 1. Press and hold the [ ]button for 2 seconds, the display will flash 12h or 24h. The device will automatically switch off after about 1 minute. However, to conserve battery power, press the button when 2. Press the [ ▲ ▲ ▲ ▲ ▲ ] button to select either 12 hour or 24 hour display. finished to turn the unit off. 3. Press the [ ] button to accept 4. The hour digits will flash. Press the [ ▲ ▲ ▲ ▲ ▲ ] button to set the hour 5. Press the [ ] button to accept ERROR ME

Summary of the content on the page No. 13

MAINTENANCE, CLEANING AND CARE SPECIFICATIONS When handled properly, this unit is engineered to give years of Measuring method : Oscillometric / non-invasive satisfactory service. Application : Adults Here are a few product care instructions: Measurement location : Wrist section of lower arm - When not in use, store the unit in the protective plastic container Circumference (approx. ) provided with your purchase. 5.3"-7.7"(13.5-19.5cm) - Do not immerse the unit in water. If the unit comes in con

Summary of the content on the page No. 14

Should you require assistance regarding this product and its operation, SYMBOL DESCRIPTIONS please contact our Customer Care Department at 1-800-853-8883 or via email at helpme@oscientific.com. Please observe user’s manual ! WARRANTY Protection class BF This product is warranted to be free of manufacturing defects for a period of 12 months from date of retail purchase. Defective product DC (Direct current) should be directed to the place of retail purchase for exchange. Should this not be possib

Summary of the content on the page No. 15

measurement again, ensure that the cuff is properly attached, the arm is in the proper position and that movement has been minimized during the measurement process. If the device does not function: - Check that the unit is on. After about 3 minutes of inactivity, the unit will automatically turn off. - Ensure that batteries are properly inserted. Batteries may be exhausted and require replacement. A battery-low indicator [ ] will display to indicate that batteries are low and need changing. Mea


Alternative user manuals
# User manual Category Download
1 Oregon BPW813 User manual Blood Pressure Monitor 5
2 Philips 319 User manual Blood Pressure Monitor 0
3 Philips HF319 User manual Blood Pressure Monitor 9
4 Philips M3860A User manual Blood Pressure Monitor 17
5 Philips M3861A User manual Blood Pressure Monitor 4
6 Philips M5066A User manual Blood Pressure Monitor 51
7 Philips HF321 User manual Blood Pressure Monitor 3
8 A&D ua-705 User manual Blood Pressure Monitor 89
9 A&D UB-521 User manual Blood Pressure Monitor 21
10 A&D UA-1030T User manual Blood Pressure Monitor 7
11 A&D UA-631 User manual Blood Pressure Monitor 288
12 A&D UA-767NFC User manual Blood Pressure Monitor 3
13 A&D Aneroid Blood Pressure Kit UA-200 User manual Blood Pressure Monitor 0
14 A&D UA-101 User manual Blood Pressure Monitor 0
15 A&D UA-704 User manual Blood Pressure Monitor 23