InterMetro Ind. FL199 user manual

User manual for the device InterMetro Ind. FL199

Device: InterMetro Ind. FL199
Category: Clothes Dryer
Manufacturer: InterMetro Ind.
Size: 0.51 MB
Added : 8/9/2014
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for InterMetro Ind. FL199. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with InterMetro Ind. FL199.

For your convenience

If looking through the InterMetro Ind. FL199 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual InterMetro Ind. FL199 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual InterMetro Ind. FL199 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
InterMetro Ind. FL199 User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual InterMetro Ind. FL199 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to InterMetro Ind. FL199. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

199 Series
Rev. 3 99
/
USER
MANUAL
FOR THE
METRO
C199 AND
FL199
SERIES
INSULATED
HEATED
CABINETS
Recommended Food Holding
Guidelines Listed on pages 5 & 6.
® ®
InterMetro Industries Corporation
Wilkes-Barre, PA 18705
570-825-2741

Summary of the content on the page No. 2

SAMPLE OF CABINET LABELING TABLE OF CONTENTS C199-HM2000 = Full Height, Holding SECTION PAGE 3 C199T-HM2000 = /4 Height, Holding I. Introduction A. Identifying Your Cabinet...............................1 OR B. Features .......................................................2 FL199-HM2000 = Full Height, High Humidity Holding II. Operating Instructions 1 FL199H-HM2000 = /2 Height, High Humidity Holding A. Reversible Doors .........................................2 B. Slide Rack Assemblies .......

Summary of the content on the page No. 3

B. FEATURES — ALL MODELS degrees and mount in the position of the top door. Align the door mounted hinge part with In order to utilize your new cabinet to its full potential, the cabinet mounted hinge part and tap the take a minute to identify the following features which hinge pin into place so top of pin is flush with have been provided for your convenience. top of the cabinet mounted hinge part. • The module has been placed at the base of the 7. Relocate the label on the door(s). Be sure that

Summary of the content on the page No. 4

CVSN/-T/-H — Model V (adjustable) C1. HM2000 HOLDING MODULE The Model V Slide Rack can be installed in either an For Recommended Holding Temperatures, inboard or outboard position. Center spacing on see HM2000 guidelines on page 6. 1 slides can be either 3" or 4 /2". Slides can be removed When equipped with a holding module, your by lifting upward and sliding the rivet heads out of the cabinet is designed to maintain the keyhole slots. To install, select spacing, insert the rivet temperature of

Summary of the content on the page No. 5

It is not necessary at the end of the operating temperature knob clockwise to increase and day to disrupt the TEMPERATURE setting in counter-clockwise to decrease temperature. order to turn the unit OFF. By switching the 5. The humidity can be adjusted by turning the POWER switch to OFF, the unit is no longer humidity knob clockwise to increase and operating. By switching the POWER switch to counter-clockwise to decrease humidity. If ON when resuming operations, the cabinet you wish to hold food

Summary of the content on the page No. 6

9. To install the module, reverse step 8. When setting for the manufacturer’s recommended installing the module into the cabinet, the time. Then, shut off the module, remove the cord must be fed through the opening in the water bottle and allow all the solution to drain cabinet back panel. Be careful that the seals out of the module quick disconnect valve. on the side of the module go inside the Empty the water bottle, and refill with clean module slides. water and a cup of baking soda and reins

Summary of the content on the page No. 7

III. FOOD HOLDING GUIDELINES A. HM2000/HM15LW Recommended Food Holding Guidelines Food Product Covered/Uncovered Temperature Setting °F* Baked Fish Uncovered 175 Baked Potatoes Uncovered 180 Biscuit Uncovered 180 Broccoli Covered 170-175 Chicken Nuggets Uncovered 175 Corn on the Cob Covered 170-175 Croissants Uncovered 175 Egg Patties Covered 180 French Fries** Uncovered 185 Fried Chicken Uncovered 180-185 Fried Fish Uncovered 180 Hamburgers Covered 180 Lasagna Covered 185 Mashed Potatoes Covere

Summary of the content on the page No. 8

If cleaning has been postponed, solvent or IV. CLEANING INSTRUCTIONS emulsion type cleaners that can be applied CAUTION with bare hands will give excellent results. AT NO TIME SHOULD THE MODULE OR Such cleaners are available under various CABINET BE WASHED OR FLOODED WITH brand names and detergent suppliers can WATER OR LIQUID SOLUTION. NEVER recommend materials appropriate for use on STEAM CLEAN. SEVERE DAMAGE OR natural and epoxy-coated aluminum. ELECTRICAL HAZARD COULD RESULT. NOTE: For every

Summary of the content on the page No. 9

VI. REPLACEMENT PARTS, PROCEDURES AND WIRING DIAGRAMS A. CABINET — ALL MODELS Refer to the Cabinet Replacement Parts Diagram on next page to identify the replacement parts. C199 Series Cabinet Replacement Parts Diagram (see page 9 for parts list) 9 28 1 10 16 13 19 5 2 8 22 23 25 8

Summary of the content on the page No. 10

CABINET REPLACEMENT PARTS LIST 1 3 ( /2 & /4 height cabinet parts not shown) Item No. Part No. Description 1 RPC199P-1102T Top Door 2 RPC199P-1102B Bottom Door 1 3 RPC199HP-1102 Door ( /2 height cabinet) 3 4 RPC199TP-1102 Door ( /4 height cabinet) 5 RPC06-809 Gasket (double door units) 1 6 RPC06-811 Gasket ( /2 height cabinet) 3 7 RPC06-810 Gasket ( /4 height cabinet) 8 RPC14-118 Door Latch (strike plate included) 9 RPC14-119 Door Hinge (complete assembly) 10 C4SC C4SC Rack (full height cabinet)

Summary of the content on the page No. 11

B. MODULE c. Remove the water pan/water bottle and drain water. Your module has been designed to be user- servicable, assuming a basic knowledge of d. Unfasten the electrical cover by removing the operation of electrical devices. This the three screws along the front of the section has been written to guide the user module and the two screws along each step by step, and in layman’s terms, through edge of the module. Retain this hardware the dismantling and servicing of the module. for re-assembl

Summary of the content on the page No. 12

Holding Module Replacement Parts Diagram REPLACEMENT PARTS LIST Item No. Part No. Description 1 RPC13-017 Power Cord — 15 AMP (HM15LW only) 2 RPC13-083 Strain Relief — 15 AMP (HM15LW only) 3 RPC06-313 Thermostat Knob 4 RPHM20-PAN Water Pan 5 RPC13-127 Power Switch 6 RPC13-129 Temperature Thermostat 7 RPC13-105 Yellow Indicator Light 8 RPHM20-2103 Circulating Blower 9 RPC13-114 Heat Element — Units with 15 Amp Plug 9 RPC13-093 Heat Element — Units with 20 Amp Plug 10 RPC13-064 Red Indicator Light

Summary of the content on the page No. 13

VI. WIRING SCHEMATICS HOLDING WIRING DIAGRAM 12

Summary of the content on the page No. 14

FL2000 High Humidity Module Replacement Parts Diagram REPLACEMENT PARTS LIST Item # Part # Description 1 RPC13-099 Power Cord — 20 AMP 2 RPC13-098 Strain Relief — 20 AMP 3 RPC06-746 Knob 4 RPC13-132 Power Switch 33 5 RPC13-181 Thermometer 6 RPC13-105 Yellow Indicator Light 21 7 RPC11-398 Heat Shield 25 22 8 RPC13-169 Buzzer Alarm 23 9 RPHM20-2103 Blower 10 RPC13-166 Heat Element 11 RPC09-117 Humidity Generator 12 RPC13-167 Band Heater 13 RPC13-168 Humidity Cut-out Switch 24 14 RPFL-3/8TUBE Tubin

Summary of the content on the page No. 15

- + FL2000 HIGH HUMIDITY MODULE WIRING DIAGRAM 14 GREEN BLACK WHITE LEAD CORD GROUND STEAMER ELEMENT WIRE NUT (TYP) STEAMER HI-TEMPERATURE 7 8 9 10 12 CUT-OUT SWITCH HEAT THERMOSTAT ELEMENT HI-TEMPERATURE CUT-OUT CAPILLARY SENSOR SWITCH 1 2 3 4 6 TERMINAL BLOCK 4 5 12 3 6 THERMOMETER POWER SUPPLY 6V DC OUTPUT THERMOMETER SENSOR 8 7 9 10 11 12 BUZZER 13 14 15 16 18 17 BLACK 0 2 4 19 20 21 22 23 24 DUCT ELEMENT 1 6 YELLOW 24 WHITE 6 20 21 22 23 19 8 1 BLUE 5 24V AC RELAY 4 RED SWITCHING 110V AC 2

Summary of the content on the page No. 16

Thank you for purchasing a Metro Mobile Heated Cabinet. We are certain you will be more than satisfied with its quality and performance. Please fill in the warranty information space below so we may register your warranty. Also, so that we may learn more about our customers and hopefully be of continued service in the future, please take a moment to fill in the customer information space below. Thank You CUT ALONG DOTTED LINE CUSTOMER INFORMATION WARRANTY INFORMATION: 1. Which one of the followi

Summary of the content on the page No. 17

NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST-CLASS PERMITNO.121 WILKES-BARRE, PA POSTAGE WILL BE PAID BY INTERMETRO INDUSTRIES CORPORATION ATTN: CUSTOMER SERVICE P O BOX A WILKES-BARRE PA 18705-9968 STAPLE HERE STAPLE HERE STAPLE HERE FOLD HERE — DO NOT DETACH

Summary of the content on the page No. 18

Warranty WARRANTY, EXCLUSION OF WARRANTIES AND LIMITATION OF LIABILITY. InterMetro Industries Corporation (hereinafter referred to as “Seller”) warrants to the original purchaser that all products in its catalog, or custom products, delivered hereunder will be free from defects in workmanship and material. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This Wa

Summary of the content on the page No. 19

L01-386 InterMetro Industries Corporation Rev. A 03/03 ® Information and specifications are subject to change North Washington Street, Wilkes-Barre, PA 18705 without notice. Please confirm at time of order. For Product Information Call: 1-800-433-2232 Visit Our Web Site: www.metro.com


Alternative user manuals
# User manual Category Download
1 InterMetro Ind. C199 User manual Clothes Dryer 1
2 ACS 882.00284.00 User manual Clothes Dryer 0
3 ACS 255 CMF (85 User manual Clothes Dryer 0
4 ACS 380 M3 /hr) User manual Clothes Dryer 0
5 Philips 1.07E+23 User manual Clothes Dryer 1
6 Philips 1.07E+31 User manual Clothes Dryer 3
7 Philips BABYSITTER SBC SC 368 User manual Clothes Dryer 17
8 Philips BABY MONITOR SBC SC368 User manual Clothes Dryer 3
9 Philips SBC SC369 User manual Clothes Dryer 0
10 Philips GL1015 User manual Clothes Dryer 0
11 Philips GL1045 User manual Clothes Dryer 0
12 ACS 255 User manual Clothes Dryer 0
13 Philips 190WV7 User manual Clothes Dryer 2
14 Philips Digital Audio Player SA 125 User manual Clothes Dryer 0
15 Philips SA 126 User manual Clothes Dryer 0