Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3 user manual

User manual for the device Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3

Device: Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3
Category: Clothes Dryer
Manufacturer: Alliance Laundry Systems
Size: 0.46 MB
Added : 4/27/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3.

For your convenience

If looking through the Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Alliance Laundry Systems Drying Tumblers 50 Pound Capacity 75 Pound Capacity Model Identification Part No. 70400301R3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operation/Programming/Maintenance
Drying Tumblers
50 Pound Capacity
75 Pound Capacity
Refer to Page 3 for Model Identification
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)

Part No. 70400301R3
www.comlaundry.com August 2007

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Installation must conform with local codes or in the absence of local codes with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.” In Canada, installation must comply with Standards CSA-B149.1 or Natural Gas and Propane Code CSA C22.1, latest edition, Canadian Electric Code, Part I. In Australia, installation must comply with the Australian Gas Association

Summary of the content on the page No. 4

Introduction......................................................................................... 3 Table of Model Identification ............................................................................. 3 Customer Service.................................................................................. 4 Contents Serial Plate Location............................................................................. 4 Wiring Diagram............................................................

Summary of the content on the page No. 5

Introduction Model Identification Information in this manual is applicable to these models: Gas Steam/Thermal Oil Electric CHD50G2-CA050L BT050T CHD50E2-CT050E CHD50G2-CA050N BU050T CHD50E2-CU050E CHD50G2-CT050L CHD50S2-CT050S DR50E2-BT050E CHD50G2-CT050N CHD50S2-CU050S DR50E2-BU050E CHD50G2-CU050L CT050T IPD50E2-IT050E CHD50G2-CU050N CU050T DR50G2-BA050L DR50S2-BT050S 50 Pound DR50G2-BA050N DR50S2-BU050S DR50G2-BT050L IPD50S2-IT050S DR50G2-BT050N IT050T DR50G2-BU050L DR50G2-BU050N IPD50G2-IT050

Summary of the content on the page No. 6

Introduction Customer Service Wiring Diagram If literature or replacement parts are required, contact The wiring diagram is located in the junction or the source from which the machine was purchased or contactor box. contact Alliance Laundry Systems at (920) 748-3950 Models starting Serial No. 0309___ or later will have for the name and address of the nearest authorized the wiring diagram part number in the lower portion of parts distributor. the electrical data on the serial plate. For te

Summary of the content on the page No. 7

Safety Information IMPORTANT: Warranty is void unless tumbler Explanation of Safety Messages is installed according to instructions in the Precautionary statements (“DANGER,” “WARNING,” Installation Manual. Compliance with minimum and “CAUTION”), followed by specific instructions, specifications and requirements detailed herein, are found in this manual and on machine decals. These and with applicable local gas fitting regulations, precautions are intended for the personal safety of the

Summary of the content on the page No. 8

Safety Information 14. The interior of the tumbler and the exhaust duct Important Safety Instructions should be cleaned periodically by qualified Save These Instructions service personnel. 15. If not installed, operated and maintained in WARNING accordance with the manufacturer’s instructions or if there is damage to or mishandling of this product’s components, use of this product could Hazardous Voltage. Can cause shock, burn expose you to substances in the fuel or from fuel or cause de

Summary of the content on the page No. 9

Safety Information 23. Remove laundry immediately after tumbler 29. DO NOT bypass any safety devices. stops. 30. Solvent vapors from dry-cleaning machines 24. Always read and follow manufacturer’s create acids when drawn through the heater of the instructions on packages of laundry and cleaning drying unit. These acids are corrosive to the aids. Heed all warnings or precautions. To reduce tumbler as well as to the laundry load being the risk of poisoning or chemical burns, keep dried. Be sur

Summary of the content on the page No. 10

Operating Instructions WARNING To reduce the risk of fire:  DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials.  DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning cloths, or anything dry-cleaned at home with a dry-cleaning solvent.  DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass. W076 To redu

Summary of the content on the page No. 11

Q U A R T E R Operating Instructions Control Instructions 1 2 3 SELECT INSERT PUSH TEMP COIN START TEMPERATURE HIGH LOW INSERT QUARTER TURN KNOB 25 PUSH TO START TMB807N TMB807N Figure 3 Electromechanical Coin Control IMPORTANT: If the loading door or lint panel door is opened during the cycle, the heating system CD and CX Control Suffixes will shut off and the motor will stop. However, the timer will continue to run. To restart the cycle, both 1. Set the TEMPERATURE selector at HIGH or do

Summary of the content on the page No. 12

Operating Instructions REVERSING MODELS TMB804N 0 0 60 10 15 50 5 20 HEAT COOL DOWN 40 10 30 TEMPERATURE HIGH LOW PUSH TO START NONREVERSING MODELS TMB805N TMB805N Figure 4 Manual Timer Control IMPORTANT: If the loading door or lint panel door is opened during the cycle, the heating system MT and RT Control Suffixes will shut off and the motor will stop. To restart the cycle, both doors must be closed and the PUSH TO 1. Set the HEAT/DRYING timer for the number of START button must be press

Summary of the content on the page No. 13

Operating Instructions REVERSING MODELS TMB2136N TMB2136N NONREVERSING MODELS TMB2133N Figure 5 IMPORTANT: To stop the tumbler at any time Dual Digital Timer Control during the cycle, OPEN DOOR. If the loading door QT and RQ Control Suffixes or lint panel door is opened during the cycle, the heating system will shut off and the motor will stop. 1. Select HIGH, MED, LOW or NO HEAT by To restart the cycle, both doors must be closed and turning the temperature knob. the START button must be

Summary of the content on the page No. 14

Operating Instructions To Program a Short Test Cycle: 1. Unplug machine power cord. 2. Write down machine control dip switch settings, O1 2 3 4 5 6 7 8 N then set them all to the off position. Refer to Figure 6. 3. Plug machine in and start a cycle. NOTE: With all control dip switches off, the total cycle time will be 1 minute long. 4. Once all testing is complete, unplug machine and re-set dip switches to their original settings. 5. Plug machine in. TMB2216N Figure 6 Error Codes WARNING

Summary of the content on the page No. 15

Operating Instructions TMB2123N Figure 7 Single Drop Control If the dry time dipswitch settings have not changed from the factory default, the IN USE LED will flash SD and SX Control Suffixes two to five times, depending on model. 1. Select HIGH, MED, LOW or NO HEAT by Ready Mode turning the temperature knob. In Ready Mode, the control waits for the vend to be 2. Insert the coin(s) in the coin slot. satisfied before entering Start Mode. 3. Press START button to start tumbler. Start Mode In

Summary of the content on the page No. 16

Operating Instructions Topoffs Temperature Selector Switch Any time the control receives a coin drop pulse during For five minutes after the control is powered up, there a cycle it will add the programmed dry time to the time is a diagnostic feature that allows the temperature currently remaining in the cycle. The maximum cycle selector switches to be tested. time is 99 minutes, the control will not add time When the temperature selector is changed, the new beyond 99 minutes. The cool down

Summary of the content on the page No. 17

Operating Instructions Diagnostic Microprocessor Control General Operation The Diagnostic Microprocessor Control (DMP) is designed to manage the drying and cooling cycles of the tumbler. The controller is also programmed from the factory with five different default programs as described below. The operator has the flexibility to select the time for the drying and the cool down cycles and the drying temperature. The operator may also select either reversing or nonreversing basket action o

Summary of the content on the page No. 18

Operating Instructions DMP Coin DV and DX Control Suffixes Description of The Coin Control Panel Refer to Figure 8. 1 2 3 MINUTES 9 HIGH 4 MEDIUM TEMP PERM. PRESS 8 5 LOW DRYING COOLING START 6 1 INSERT COIN (S) INSTRUCTIONS 2 SELECT TEMP. 3 PUSH START TMB1955N 7 TMB1955N 1 Clock Symbol. This symbol of a clock indicates that the time in the display is counting down to zero. 2 Display. Displays the drying time, cooling time, drying temperature, and diagnostics. 3 Hidden Keys. Used for programm

Summary of the content on the page No. 19

Operating Instructions DMP Coin Features 3. The hidden front panel increment and decrement keys are used to change the value. Coin Keypad Interface 4. The CLEAR button is used to recall the default - START button to start or resume a cycle. value. - TEMP button to select HIGH, MEDIUM, or LOW 5. The START button is used to step to the next temperature. parameter. - Two hidden buttons to increment or decrement the 6. After the last parameter, “End” will be flashing. programmable time and te

Summary of the content on the page No. 20

Operating Instructions DMP OPL Models DO Control Suffix Description of the OPL Control Panel Refer to Figure 9. 6 5 8 1 2 7 3 4 5 DRYING 8 9 4 COOLING TEMPERATURE 10 11 REV START STOP 12 (CANCEL) 3 1 2 TMB1956N TMB1956N 1 START. Starts or resumes the current program or cycle. 2 STOP. Temporarily halts the current cycle or cancels the current program. 3 Reversing/Nonreversing (REV). Changes the selection between reversing and nonreversing cylinder action. 4 Reversing LED. Illuminated when set fo


Alternative user manuals
# User manual Category Download
1 Alliance Laundry Systems D310IE3B User manual Clothes Dryer 6
2 Alliance Laundry Systems 602004144 User manual Clothes Dryer 5
3 Alliance Laundry Systems 250 C.F.M. User manual Clothes Dryer 3
4 Alliance Laundry Systems 80 User manual Clothes Dryer 2
5 Alliance Laundry Systems 25 User manual Clothes Dryer 1
6 Alliance Laundry Systems DRY2024N User manual Clothes Dryer 1
7 Alliance Laundry Systems 512685R2 User manual Clothes Dryer 1
8 Alliance Laundry Systems 70420801 User manual Clothes Dryer 0
9 Alliance Laundry Systems D0582 User manual Clothes Dryer 1
10 Alliance Laundry Systems DRY2029N User manual Clothes Dryer 1
11 Alliance Laundry Systems DRY2035N User manual Clothes Dryer 1
12 Alliance Laundry Systems DRY2032N User manual Clothes Dryer 1
13 Alliance Laundry Systems DRY2038N User manual Clothes Dryer 1
14 Alliance Laundry Systems DRY2031N User manual Clothes Dryer 1
15 Alliance Laundry Systems DRY2037N User manual Clothes Dryer 1
16 ACS 882.00284.00 User manual Clothes Dryer 0
17 ACS 255 CMF (85 User manual Clothes Dryer 0
18 ACS 380 M3 /hr) User manual Clothes Dryer 0
19 Philips 1.07E+23 User manual Clothes Dryer 1
20 Philips 1.07E+31 User manual Clothes Dryer 3