Baldor FLEXIDYNE 11C user manual

User manual for the device Baldor FLEXIDYNE 11C

Device: Baldor FLEXIDYNE 11C
Category: Air Compressor
Manufacturer: Baldor
Size: 0.24 MB
Added : 3/6/2014
Number of pages: 7
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Baldor FLEXIDYNE 11C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Baldor FLEXIDYNE 11C.

For your convenience

If looking through the Baldor FLEXIDYNE 11C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Baldor FLEXIDYNE 11C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Baldor FLEXIDYNE 11C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Baldor FLEXIDYNE 11C User manual - Online PDF
Advertisement
« Page 1 of 7 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Baldor FLEXIDYNE 11C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Baldor FLEXIDYNE 11C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTRUCTION MANUAL
FOR
®
FLEXIDYNE Couplings
Sizes 9C and 11C

WARNING: Because of the possible danger to persons(s) or property from accidents which may result from the improper use of products, it is
important that correct procedures be followed. Products must be used in accordance with the engineering information specified in the catalog.
Proper installation, maintenance and operation procedures must be observed. The instructions in the instruction manuals must be followed.
Inspection

Summary of the content on the page No. 2

2

Summary of the content on the page No. 3

START-UP DESCRIPTION 1. Remove one of the filler plugs and install ½ the proper FLEXIDYNE dry fluid couplings are a unique concept amount of flow charge specified in Table 1. Replace and to provide soft start and momentary overload protection for tighten filler plug, making sure that no flow charge is all types of driven equipment. Standard NEMA-B motors trapped in the threads. Remove other filler plug and install with RPM base speeds of 1750, 1160 or 860 are the remaining ½ of specifi

Summary of the content on the page No. 4

the same acceleration time. A longer time between starts MAINTENANCE will dissipate more heat; therefore, higher starting For average industrial applications involving 3 or 4 horsepowers may be transmitted, or longer acceleration starts a day of not more than 6 seconds acceleration time times may be allowable. (See Starting Cycle) each, the flow charge should be changed every 10,000 Acceleration times shown in Table 1 are for starting hours of operation. For more severe conditions, visu

Summary of the content on the page No. 5

Table 1 – Flow Charge Recommendations (cont.) Based on % of Starting Torque for 1175 RPM NEMA Design B Motors 100% @ 1175 RPM 125% @ 1160 RPM 150% @ 1150 RPM 175% @ 1130 RPM 200% @ 1100 RPM Flow Max. Flow Max. Flow Max. Flow Max. Flow Max. Start- Start- Start- Start- Start- Rated FLEXI- Charge Time Charge Time Charge Time Charge Time Charge Time ing ing ing ing ing Motor DYNE In In In In In HP Size HP HP HP HP HP Lbs. Oz. Lbs. Oz. Lbs. Oz. Lbs. Oz. Lbs. Oz. Sec. Sec. Sec. Sec. Sec

Summary of the content on the page No. 6

Reassembly: 1. Install new seal felt and replace seal shield in drive housing. 2. Install housing seal (red in color) on rotor retainer and set rotor retainer in place in drive housing. Make certain housing seal does not twist and that it is properly seated in the drive housing. 3. Press ball bearings onto drive housing. Note: Press against inner (not outer) race of bearing. Make certain rotor retainer is not cocked when bearing enters it. Check to see that rotor retainer r

Summary of the content on the page No. 7

FLEXIDYNE Trouble Analysis Symptom Cause Cure Vibration 1. Misalignment 1. Realign drive or coupling. 2. Bent shaft 2. Replace or straighten. 3. Excess flow charge 3. Remove small amount of flow charge. 4. Fused flow charge 4. Correct the overload. 5. Improper installation – Output shaft jammed 5. Readjust spacing between shafts and against housing FLEXIDYNE. Erratic Acceleration 1. Breakdown of flow charge 1. Replace flow charge. 2. Caked flow charge 2. Moist environment – use sta


Alternative user manuals
# User manual Category Download
1 Baldor FLEXIDYNE 9C User manual Air Compressor 3
2 Directed Electronics 350HV User manual Air Compressor 5
3 12Volt 12V6CF User manual Air Compressor 2
4 Alesis 3630 User manual Air Compressor 260
5 AllTrade 835533 User manual Air Compressor 1
6 AllTrade 835579 User manual Air Compressor 3
7 AllTrade 830211 User manual Air Compressor 4
8 AllTrade 835446 User manual Air Compressor 1
9 AllTrade 835534 User manual Air Compressor 0
10 AllTrade 835408 User manual Air Compressor 1
11 Acer AX3910-U2032 User manual Air Compressor 29
12 AllTrade Trades Pro 835081 User manual Air Compressor 18
13 American Eagle Outfitters American Eagle Compressor User manual Air Compressor 7
14 AllTrade #540025 User manual Air Compressor 2
15 American Eagle Outfitters HV-60 User manual Air Compressor 2