Sunrise Medical 3655D user manual

User manual for the device Sunrise Medical 3655D

Device: Sunrise Medical 3655D
Category: Air Compressor
Manufacturer: Sunrise Medical
Size: 0.5 MB
Added : 5/10/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sunrise Medical 3655D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sunrise Medical 3655D.

For your convenience

If looking through the Sunrise Medical 3655D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sunrise Medical 3655D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sunrise Medical 3655D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sunrise Medical 3655D User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sunrise Medical 3655D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sunrise Medical 3655D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
DeVilbiss Compressor/Nebulizer Instruction Guide
®
Pulmo-Aide Models 5650C, 5650D, 5650H, 5650I, 5650K & 5650P
®
PulmoMate Models 4650D, 4650I & 46502
®
Pulmo-Aide Compact Models 3655D, 3655I, 3655K, 3655P & 3655T
CAUTION– Federal (U.S.A.) law restricts this device to sale by, or on the order of a physician.
Made in U.S.A. of U.S. and imported parts. Latex Free.
Models 4650D, 46502, 5650D, & 5650H UL Listed. Model 5650C CSA Listed.
Models 3655D & 3655T Entela Certified to UL1431, CAN/CSA

Summary of the content on the page No. 2

2 Table of C ontents ENGLISH IEC Symbols................................................................................... 3 Important Safeguards...................................................................... 3 Model 5650H & 4650D Grounding Instructions .................................... 4 Introduction .................................................................................. 5 Important Parts of Your DeVilbiss 4650 or 5650 Compressor.................. 6 Important Parts of Yo

Summary of the content on the page No. 3

3 I mpor tant S afeguar ds IEC SYMBOLS Attention, consult instruction This device contains electrical Type BF Applied Part guide. and/or electronic equipment that must be recycled per EC Directive 2002/96/EC - Waste Alternating Current Electrical and Electronic Double Insulated Equipment (WEEE) IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precau- tions should always be followed. Read all instructions before using. Important information i

Summary of the content on the page No. 4

4 I mpor tant S afeguar ds 9. Do not use outdoors. This product is for household use only. 10. Do not use in an oxygen enriched environment. 11. Connect this product (for grounded models) to a properly-grounded outlet only. See Grounding Instructions. 12. Do not use this product with a DC to AC converter, or with any AC voltage and/or frequency other than specified. 13. Do not operate unit in a backpack or carrying bag. 14. Care should be taken when this product is used in the vicinity of other

Summary of the content on the page No. 5

5 I mpor tant S afeguar ds / I ntr oduction 2. If it is necessary to use an extension cord, use only a 3-wire extension cord that has a three-blade grounding plug, and a 3-slot receptacle that will accept the plug on the unit. If power cord is damaged do not use unit, and contact a qualified Sunrise Medical provider. SAVE THESE INSTRUCTIONS Grounded Outlet Box Grounded Adapter Outlet Tab for Grounding Screw Grounding Pin B C A INTRODUCTION Your doctor has prescribed a liquid medication to treat

Summary of the content on the page No. 6

6 I mpor tant Par ts of Your C ompr essor IMPORTANT PARTS OF YOUR DEVILBISS 4650 OR 5650 COMPRESSOR (Figures A & B) 2 1. Storage compartment 8 7 2. Storage compartment door with operating instructions 3 3. Power switch 4 1 4. Filter cap 5 5. Air-outlet connector 6. Carrying handle 6 7. Power cord storage Figure A– 4650 8. Nebulizer holder 6 (on back) NOTE– Models 4650D & 5650H are equipped with a three- prong plug and must be grounded. All other models 8 1 are equipped with a two-prong plug. 7

Summary of the content on the page No. 7

7 I mpor tant Par ts of Your N ebuliz er IMPORTANT PARTS OF YOUR DISPOSABLE NEBULIZER 1. Mouthpiece 1 2 2. T-piece 3 3. Cap 4. Medication Cup 5. Nebulizer Air-Inlet Connector 4 6. Baffle 6 5 7. Tubing 7 Nebulizer parts are not sold separately. Additional nebulizers Disposable Nebulizer (part #4650D-621) are available through your Sunrise provider. 1 IMPORTANT PARTS OF YOUR REUSABLE NEBULIZER 1. Mouthpiece 2 2. Cap 3 3. Baffle 4. Medication Cup 4 5. Nebulizer Air-Inlet Connector 6. Interrupter Ad

Summary of the content on the page No. 8

8 H o w to Operate Your C ompr essor Models 3655 (Steps 1-3 and Steps 4-12) 1. Make sure the power switch is in the “Off” position (Fig. 1) and unwrap power cord. 2. Place compressor so that the rubber feet are resting on a level, sturdy surface (Fig. 3) and upon which the controls can be easily reached when seated. Never block the air openings of the product or place it on a soft surface, such as a patient’s lap or a bed or couch where the air openings may be blocked. 3. Plug power cord into

Summary of the content on the page No. 9

9 Cleaning 11. If an aerosol mask is used, place the mask over mouth and nose (Fig. 8). As aerosol begins to flow, inhale deeply and slowly through mouth, then exhale slowly. 12. When treatment is complete, turn unit off by press- ing the power switch to the “Off” position. Unplug the unit from the wall power outlet. NEBULIZER CLEANING All parts of the nebulizer, except tubing, should be cleaned Figure 7 according to the following instructions. Your physician and/or Sunrise provider may specif

Summary of the content on the page No. 10

10 Cleaning Disinfect Daily: 1. Using a clean container or bowl, soak items in three parts hot water to one part white vinegar for 30 minutes (Fig. 9) OR use a medical bacterial-germici- dal disinfectant available through your provider. Be sure to follow manufactur- er's instructions carefully. 2. With clean hands, remove items from disinfectant solution, rinse under hot tap water, and air dry on a clean paper towel. Store in a zip-lock bag. NOTE– Do not towel dry nebulizer parts; this could cau

Summary of the content on the page No. 11

11 F ilter Change / M aintenance FILTER CHANGE Models 4650 & 5650 1. Filter should be changed every 6 months or sooner if filter turns completely gray in color. 2. Remove filter cap by grasping it firmly and pulling out of the unit (Figs. A or B). 3. Remove dirty filter with fingers and discard. 4. Replace with a new DeVilbiss filter (part #5650D-602). Additional filters should be purchased from your Sunrise provider. 5. Push filter cap with new filter into position. CAUTION– Do not reuse or wa

Summary of the content on the page No. 12

12 S pecifications SPECIFICATIONS Size 3655 Series...................7.5" W x 4.0" H x 7.2" D (19.1 cm x 10.2 cm x 18.3 cm) 4650 Series ..............................7" W x 3.8" H x 13" D (18 cm x 10 cm x 33 cm) 5650 Series .......................10.1" W x 10.5" H x 6.5" D (26 cm x 27 cm x 17 cm) Weight 3655 Series.....................................................................4.8 lbs. (2.18 kg) 4650 Series.....................................................................5.3 lbs. (2.40

Summary of the content on the page No. 13

13 Warranty FIVE-YEAR LIMITED WARRANTY ON COMPRESSOR PARTS All DeVilbiss Compressor models are warranted to be free from defective workmanship and material for a period of five years from the date of purchase. Any defective part(s) will be repaired or replaced at Sunrise’s option if the unit has not been tampered with or used improperly during that period. Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions. If repair is necessary, contact yo

Summary of the content on the page No. 14

14 P r ecauciones I mpor tantes SIMBOLOS IEC Atención, consulte la guía de Este aparato contiene equipo Parte aplicada Tipo BF instrucciones eléctrico y/o electrónico que debe ser reciclado de acuerdo a la Norma EC 2002/96/EC – Corriente alterna Equipo Eléctrico y Electrónico Doble aislamiento Residual (WEEE) PRECAUCIONES IMPORTANTES Cuando use productos eléctricos, especialmente cuando hay niños presentes, siempre deben tomarse las precauciones básicas de seguridad. Lea todas las instrucciones

Summary of the content on the page No. 15

15 P r ecauciones I mpor tantes 7. Nunca lo use cuando esté somnoliento o adormecido. 8. Nunca deje caer ni introduzca un objeto en ninguna abertura o manguera del producto. 9. No lo use en exteriores. Este producto es para usarse solamente en el hogar. 10. No lo use en un ambiente enriquecido de oxígeno. 11. Conecte este producto (para los modelos a tierra) a una toma de corriente puesta a tierra apropiadamente. Vea las Instrucciones de Puesta a Tierra. 12. No utilice este producto con un trans

Summary of the content on the page No. 16

16 P r ecauciones I mpor tantes C, para conectar este enchufe en un tomacorriente bipolar (como se muestra en la Figura B) si no se encuentra disponible un tomacorriente puesto a tierra debida- mente. El adaptador temporal debe usarse solamente hasta que un electricista califi- cado pueda instalar un tomacorriente puesto a tierra debidamente (Figura A). El saliente para toma de tierra, pestaña o cable que sobresale del adaptador debe estar conectado a una toma de tierra permanente como la tapa d

Summary of the content on the page No. 17

17 Par tes I mpor tantes PARTES IMPORTANTES DE SU COMPRESOR DEVILBISS MODELOS 4650 O 5650 2 (Figuras A y B) 8 7 1. Compartimiento para guardar 3 4 2. Puerta del compartimiento para guardar con instruc- 1 ciones de operación 5 3. Interruptor de corriente 6 4. Tapa del filtro 5. Conector de salida de aire Figura A– 4650 6. Mango de transporte 6 7. Depósito para cordón eléctrico 8. Soporte del nebulizador 8 1 NOTA– Los modelos 4650D y 5650H están equipados con un 7 2 enchufe de tres clavijas y de

Summary of the content on the page No. 18

18 Par tes I mpor tantes PARTES IMPORTANTES DE SU NEBULIZADOR DESECHABLE 1 2 1. Pieza bucal 3 2. Pieza-T 3. Tapa 4. Copa del medicamento 4 5. Conector de entrada del aire 6 5 7 6. Deflector 7. Conducto Nebulizador Desechable Las partes del nebulizador se venden por separado. Se cuen- 1 ta con nebulizadores adicionales (parte No. 4650D-621) que puede conseguir a través de su distribuidor Sunrise. 2 PARTES IMPORTANTES DE SU NEBULIZADOR 3 REUTILIZABLE 1. Pieza bucal 4 2. Tapa 5 3. Deflector 4. Co

Summary of the content on the page No. 19

19 Cómo Operar su C ompr esor trica de pared apropiada (vea las Especificaciones). Enchufe los modelos 5650H y 4650D en un tomacorri- ente puesto a tierra (vea las Instrucciones Para la Puesta a Tierra al reverso). PELIGRO El compresor/nebulizador DeVilbiss debe operarse en la fuente de poder específica para evitar una descarga eléctrica y dañar el compresor. Modelos 3655 (Pasos 1-3 y pasos 4-12) Figura 3 1. Asegure que el interruptor de corriente se encuentra en la posición "OFF" (Fig. 1) y des

Summary of the content on the page No. 20

20 L impieza 8. Fije el conducto del conector de la entrada de aire del nebulizador (Fig. 6). 9. Oprima el interruptor de corriente en “On” (Fig. 1) para encender el compresor. 10. Comience el tratamiento colocando la pieza bucal entre los dientes. Con la boca cerrada, inhale pro- funda y lentamente por la boca y el aerosol comen- zará a fluir, luego exhale lentamente por la pieza bucal (Fig. 7). Si es necesario interrumpir el Figura 7 tratamiento, simplemente oprima el interruptor de corriente


Alternative user manuals
# User manual Category Download
1 Sunrise Medical 3655I User manual Air Compressor 0
2 Sunrise Medical 4650I User manual Air Compressor 0
3 Sunrise Medical 46502 User manual Air Compressor 10
4 Sunrise Medical 4650D User manual Air Compressor 2
5 Sunrise Medical 3655P User manual Air Compressor 1
6 Sunrise Medical 3655K User manual Air Compressor 1
7 Sunrise Medical 3655T User manual Air Compressor 0
8 Sunrise Medical 5650D User manual Air Compressor 30
9 Sunrise Medical 5650C User manual Air Compressor 1
10 Sunrise Medical 5650I User manual Air Compressor 1
11 Sunrise Medical 5650H User manual Air Compressor 2
12 Sunrise Medical 5650P User manual Air Compressor 0
13 Sunrise Medical 5650K User manual Air Compressor 0
14 Directed Electronics 350HV User manual Air Compressor 5
15 12Volt 12V6CF User manual Air Compressor 2
16 Alesis 3630 User manual Air Compressor 260
17 AllTrade 835533 User manual Air Compressor 1
18 AllTrade 835579 User manual Air Compressor 3