Therma-Stor Products Group 4025273 user manual

User manual for the device Therma-Stor Products Group 4025273

Device: Therma-Stor Products Group 4025273
Category: Dehumidifier
Manufacturer: Therma-Stor Products Group
Size: 0.83 MB
Added : 6/14/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Therma-Stor Products Group 4025273. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Therma-Stor Products Group 4025273.

For your convenience

If looking through the Therma-Stor Products Group 4025273 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Therma-Stor Products Group 4025273 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Therma-Stor Products Group 4025273 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Therma-Stor Products Group 4025273 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Therma-Stor Products Group 4025273 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Therma-Stor Products Group 4025273. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Issue 09/04
Santa Fe HC Dehumidifier
The Santa Fe HC dehumidifier performs multiple
functions in a compact enclosure, including
high-capacity dehumidification and air filtration.
True Performance
Off-the shelf, appliance grade dehumidifiers rate
their dehumidification capacities at 80°F, 60%
relative humidity (RH). The performance of these
devices drops significantly at cooler temperatures
typically found in basements and crawlspaces.
That means you may have to purchase multiple
off-the-sh

Summary of the content on the page No. 2

Table of Contents Introduction 1 1 Intended Application for Santa Fe HC Features & Benefits 1 Precautions 2 For the ideal installation, draw air from the central part of 1. Intended Application 2 the home and return it to isolated areas of the home like the 2. Registration 2 bedrooms, den, utility room, or family room. The ductwork 3. Specifications 2 of the existing forced air system can be used to supply air 4. Installation 2 to the home. 4.1 Location 2 4.1A In Humid Area, No Ducting 3

Summary of the content on the page No. 3

4.1A in Humid Area, No Ducting (Fig. 4) The simplest installation is to place the Santa Fe HC in the humid area with no ducting. To ensure Inlet Output optimal performance the air inlet and the outlet of the unit must be at least 1' from walls and other obstructions to air flow. Figure 4: Installation in humid area with no ducting. 4.1B In The Humid Area, Duct Inlet and/or Outlet (Fig. 5) Inlet If the humid area is large or has high ceilings, dehumidification can be improved by adding

Summary of the content on the page No. 4

4.1D In A Remote Area, Duct Outlet Only (Fig. 7) A simplified remote installation method than above uses ducting between the Santa Fe HC discharge and the humid room; the Santa Fe HC inlet draws air from the room in which it's located. This works well if Output there is an adequate air flow path between the two rooms; e.g. high door undercut, louvered door or wall grill. This eliminates the need to remote mount the humidity control. WARNING Inlet Before installing the dehumidifier in the mann

Summary of the content on the page No. 5

4.5 Drainage and Trap 6 Operation The Santa Fe HC requires a trap. Unit should be located in an area where the unit’s condensate (water) may be easily routed 6.1 Humidity Control Adjustment to a suitable drain. Figure 13: Humidity control dial. Thread the PVC barb fitting into the drain outlet on the front of the unit. Push the hose onto the barb fitting past two barbs minimum to ensure a good fit. Figure 10: PVC Figure 11: Drain outlet barb fitting. Route the drain hose through the trap as sho

Summary of the content on the page No. 6

6.2 Blower (Fan) Switch the refrigerant pressure and temperature to drop. It next Turning “ON” the fan switch will cause the unit's internal enters the evaporator coil where it absorbs heat from the incoming air and evaporates. blower to run continuously, whether the unit is dehumidifying or not. This function is desirable if the unit is used for air circulation. Turning “OFF” the fan switch will cause the unit’s internal blower to run only while the unit is dehumidifying. Figure 15: Blower fan

Summary of the content on the page No. 7

Evaporator coil frosted continuously, low 11 Wiring Diagram dehumidifying capacity. 1. Defrost thermostat loose or defective. 2. Low refrigerant charge 3. Dirty air filter or air flow restricted. 8.3 Defrost Thermostat The defrost thermostat is attached to the refrigerant suction tube between the accumulator and compressor. It will automatically shut the compressor off if the low side refrigerant temperature drops due to excessive frost formation on the evaporator coil. The blower will conti

Summary of the content on the page No. 8

Santa Fe HC Dehumidifier Limited Warranty and does not cover any defect, malfunction, etc. WARRANTOR: resulting from misuse, abuse, lack of normal care, Therma-Stor LLC corrosion, freezing, tampering, modification, PO Box 8050 unauthorized or improper repair or installation, accident, acts of nature or any other cause Madison, WI 53708 beyond Therma-Stor LLCs reasonable control. Telephone: 1-800-533-7533 LIMITATIONS AND EXCLUSIONS: If any SANTA FE HC Dehumidifier part is repaired or replaced,

Summary of the content on the page No. 9

Santa Fe HC Owners Manual 9

Summary of the content on the page No. 10

PO Box 8050 1919 S. Stoughton Road Madison, WI 53708 Information in this document is subject to change without notice. Phone: 608-222-5301 No part of this document may be reproduced or transmitted in any Fax: 608-222-1447 form or by any means, electronic or mechanical, for any purpose, Web: www.thermastor.com without the express written permission of Therma-Stor LLC. Email: sales@thermastor.com © 2004 Therma-Stor LLC. All rights reserved. 10 Santa Fe HC Owners Manual


Alternative user manuals
# User manual Category Download
1 Therma-Stor Products Group 90H User manual Dehumidifier 0
2 Therma-Stor Products Group Phoenix 200 HT User manual Dehumidifier 0
3 Therma-Stor Products Group PHOENIX 300 User manual Dehumidifier 0
4 Therma-Stor Products Group HI-E Dry Vehere User manual Dehumidifier 0
5 Therma-Stor Products Group R175 User manual Dehumidifier 1
6 Therma-Stor Products Group PHOENIX D385 User manual Dehumidifier 0
7 Therma-Stor Products Group UA-135H User manual Dehumidifier 0
8 Therma-Stor Products Group Santa-Fe Rx Free-Standing Dehumidification User manual Dehumidifier 2
9 Therma-Stor Products Group UA-150H User manual Dehumidifier 0
10 Therma-Stor Products Group XT150H User manual Dehumidifier 0
11 Therma-Stor Products Group Ultra-Aire 100V User manual Dehumidifier 1
12 Therma-Stor Products Group Ultra-Aire DEH 3000R User manual Dehumidifier 1
13 Therma-Stor Products Group 200 MAX User manual Dehumidifier 0
14 Eaton Electrical TR3 User manual Dehumidifier 2
15 Airstream LAND YACHT MOTORHOME User manual Dehumidifier 1
16 Alen MDF-50AE User manual Dehumidifier 4
17 Alen MDF-70AE User manual Dehumidifier 2
18 Amcor D850E User manual Dehumidifier 29