Teledyne T802 user manual

User manual for the device Teledyne T802

Device: Teledyne T802
Category: Respiratory Product
Manufacturer: Teledyne
Size: 8.32 MB
Added : 11/20/2013
Number of pages: 314
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne T802. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne T802.

For your convenience

If looking through the Teledyne T802 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne T802 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne T802 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne T802 User manual - Online PDF
Advertisement
« Page 1 of 314 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne T802 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne T802. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






OPERATION MANUAL

MODEL T802
PARAMAGNETIC OXYGEN ANALYZER




© TELEDYNE ADVANCED POLLUTION INSTRUMENTATION
9480 CARROLL PARK DRIVE
SAN DIEGO, CA 92121-5201
USA

Toll-free Phone: 800-324-5190
Phone: 858-657-9800
Fax: 858-657-9816
Email: api-sales@teledyne.com
Website: http://www.teledyne-api.com/


Copyright 2010-2013 07275B DCN6418
Teledyne Advanced Pollution Instrumentation 14 January 2013

Summary of the content on the page No. 2

Summary of the content on the page No. 3

ABOUT TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI) Teledyne Advanced Pollution Instrumentation, Inc. (TAPI) is a worldwide market leader in the design and manufacture of precision analytical instrumentation used for air quality monitoring, continuous emissions monitoring, and specialty process monitoring applications. Founded in San Diego, California, in 1988, TAPI introduced a complete line of Air Quality Monitoring (AQM) instrumentation, which comply with the United States Enviro

Summary of the content on the page No. 4

Teledyne API T802 Paramagnetic O2 Analyzer Operation Manual This page intentionally left blank. ii 07275B DCN6418

Summary of the content on the page No. 5

SAFETY MESSAGES Important safety messages are provided throughout this manual for the purpose of avoiding personal injury or instrument damage. Please read these messages carefully. Each safety message is associated with a safety alert symbol, and are placed throughout this manual; the safety symbols are also located inside the instrument. It is imperative that you pay close attention to these messages, the descriptions of which are as follows: WARNING: Electrical Shock Hazard HAZA

Summary of the content on the page No. 6

Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 CONSIGNES DE SÉCURITÉ Des consignes de sécurité importantes sont fournies tout au long du présent manuel dans le but d’éviter des blessures corporelles ou d’endommager les instruments. Veuillez lire attentivement ces consignes. Chaque consigne de sécurité est représentée par un pictogramme d’alerte de sécurité; ces pictogrammes se retrouvent dans ce manuel et à l’intérieur des instruments. Les symboles correspondent aux consigne

Summary of the content on the page No. 7

WARRANTY WARRANTY POLICY (02024F) Teledyne Advanced Pollution Instrumentation (TAPI), a business unit of Teledyne Instruments, Inc., provides that: Prior to shipment, TAPI equipment is thoroughly inspected and tested. Should equipment failure occur, TAPI assures its customers that prompt service and support will be available. COVERAGE After the warranty period and throughout the equipment lifetime, TAPI stands ready to provide on-site or in-plant service at reasonable rates similar t

Summary of the content on the page No. 8

Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 This page intentionally left blank. vi 07275B DCN6418

Summary of the content on the page No. 9

ABOUT THIS MANUAL This operation manual, PN 07275, is comprised of multiple documents in PDF format, as listed below. Part No. Rev Name/Description 07275 B T802 Operation manual 06530 C Menu Trees and Software Documentation (inserted as Appendix A in this manual) 07269 A Spare Parts List (located in Appendix B of this manual) 06535 A Expendables Kit (located in Appendix B of this manual) 06532 C Repair Request Form (inserted as Appendix C in this manual) Appendix D Documents: 0738001

Summary of the content on the page No. 10

Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 CONVENTIONS USED In addition to the safety symbols as presented in the Important Safety Information page, this manual provides special notices related to the safety and effective use of the analyzer and other pertinent information. Special Notices appear as follows: COULD DAMAGE INSTRUMENT AND VOID WARRANTY ATTENTION This special notice provides information to avoid damage to your instrument and possibly invalidate the warran

Summary of the content on the page No. 11

TABLE OF CONTENTS ABOUT TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI).......................................................................... i Safety Messages ...................................................................................................................................................iii Warranty ................................................................................................................................................................ v

Summary of the content on the page No. 12

Table of Contents Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 5.7.1. ID (Machine Identification).....................................................................................................................83 5.7.2. INET (Ethernet) .....................................................................................................................................84 5.7.3. COM1[COM2] (Mode, Baude Rate and Test Port) ......................................................

Summary of the content on the page No. 13

Teledyne API T802 Paramagnetic O Analyzer Operation Manual Table of Contents 2 9.4.1. Pressure Calibration............................................................................................................................176 9.4.2. Flow Calibration...................................................................................................................................178 9.5. Calibration of the Optional CO Sensor...............................................................

Summary of the content on the page No. 14

Table of Contents Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 12.1.1. Magnetic Properties of O Gas..........................................................................................................219 2 12.1.2. Principle of Measurement..................................................................................................................219 12.2. NDIR Measurement of CO ...........................................................................................

Summary of the content on the page No. 15

Teledyne API T802 Paramagnetic O Analyzer Operation Manual Table of Contents 2 Figure 4-1: Front Panel Touchscreen and Display ........................................................................... 64 Figure 4-2: Viewing Test Functions .................................................................................................. 65 Figure 5-1: Analog Output Connector Pin Out.................................................................................. 71 Figure 5-2: Setup for Ch

Summary of the content on the page No. 16

Table of Contents Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 Table 4-2: Test Functions Defined .................................................................................................. 66 Table 6-4: Primary Setup Mode Features and Functions................................................................ 67 Table 6-5: Secondary Setup Mode Features and Functions........................................................... 68 Table 5-2: Variable Names (VARS)............

Summary of the content on the page No. 17

PART I – GENERAL INFORMATION AND SETUP 07275B DCN6418 15

Summary of the content on the page No. 18

Section 1 General Information Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 This page intentionally left blank. 16 07275B DCN6418

Summary of the content on the page No. 19

1. INTRODUCTION, FEATURES AND OPTIONS 1.1. T802 OVERVIEW The Model T802 (also referred to as T802) Paramagnetic Oxygen Analyzer is a microprocessor-controlled analyzer that determines the concentration of molecular oxygen (O ) in a sample gas drawn through the instrument. It uses a 2 paramagnetic sensor that relies on the relatively high reactivity of O molecules 2 to magnetic fields to generate a current that is proportional to the amount of O 2 present in the sensor chamber. The T80

Summary of the content on the page No. 20

Introduction, Features and Options Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 HAZARD Strong Oxidizer OXYGEN IS A STRONG OXIDIZER. This is a general purpose instrument designed for usage in nonhazardous areas. Ensure that all safety precautions related combustible gases are followed. Before working with the casing open, be sure to turn off power to the analyzer, and perform air or N gas purging of not only the analyzer inside, but also the sample gas line. 2 In a


Alternative user manuals
# User manual Category Download
1 Teledyne TED 191 User manual Respiratory Product 2
2 Teledyne 3020T User manual Respiratory Product 21
3 Teledyne Trace Oxygen Analyzer 3000TA User manual Respiratory Product 13
4 Teledyne 3190Z User manual Respiratory Product 1
5 Teledyne Trace Oxygen Analyzer 3000TA-XL-EU User manual Respiratory Product 26
6 Teledyne MX300 User manual Respiratory Product 12
7 Teledyne 3300ZB User manual Respiratory Product 0
8 Teledyne MX300-I User manual Respiratory Product 103
9 Agilent Technologies 54600-Series User manual Respiratory Product 6
10 3M 9210 User manual Respiratory Product 3
11 3M 7000 Series User manual Respiratory Product 1
12 3M FR-M40 User manual Respiratory Product 6
13 3M 9211 User manual Respiratory Product 3
14 AOSafety OMNI STAR User manual Respiratory Product 1
15 AOSafety Eye Gear Rotational Display A1655 User manual Respiratory Product 1