Bayer HealthCare 2 user manual

User manual for the device Bayer HealthCare 2

Device: Bayer HealthCare 2
Category: Blood Glucose Meter
Manufacturer: Bayer HealthCare
Size: 3.31 MB
Added : 7/23/2013
Number of pages: 53
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bayer HealthCare 2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bayer HealthCare 2.

For your convenience

If looking through the Bayer HealthCare 2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bayer HealthCare 2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bayer HealthCare 2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bayer HealthCare 2 User manual - Online PDF
Advertisement
« Page 1 of 53 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bayer HealthCare 2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bayer HealthCare 2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User Guide
For Use With
® ®
Ascensia Breeze
Blood Glucose Meter and
® ®
Ascensia Breeze
Unique 10-Test Disc

Summary of the content on the page No. 2

Smaller Blood Drop, Faster Test Results, and IncreasedM emoryC apacity a s Easy as 1-2-3... 1 Open meter, insert 10-test disc, close meter. 1 2 Pull (a) and push (b) handle to expose test strip. 2 3 Apply sample. 3 Bayer Diabetes Care Helpline: 1-800-268-7200 b a NEW!

Summary of the content on the page No. 3

t B a lE of c ontEnts IIntroduct on I Introduct on 1 AL ook At Y our M eter 2 e xpLAA n It on of d ILA sp Y s YML bo s 4 t estIng M AterIALs 6 EvEyydar u E s I Itnser ng A10- t est d Isc 7 r unnIng A b Lood g Lucose t est 10 marking a deleted blood test 17 anding your test resul underst ts 18 r unnIng A c ontroL t est 20 marking a control test 22 BEyond EE v yydar u E s r ALLI ec ng t est r L esu ts 24

Summary of the content on the page No. 4

t B a lE of c E ont nts t EIchn cal IItnforma on s Ipec fIcA tIons 38 p erforMAnce e v ALA u It ons 38 s vIol ng ProBlEms s L o Iv ng p L rob eMs 39 t roubLeshootIng And e rror c odes 40 c M usto er s Ierv ce 45 r LA ep M ce ent I M te s 46 W ArrAY nt I nforMA tIon 47 ® ® The Ascensia BREEZE Blood Glucose Monitoring System (meter, test strips and controls) is intended for self-testing by persons with diabetes and by healthcare professiona

Summary of the content on the page No. 5

IIntroduct on IntroductIon : ® ® Thank you for choosing the Ascensia Breeze Blood Glucose Monitoring System! We are proud to be your partner in helping you manage your diabetes. We understand that people who regularly check their blood glucose levels want a meter that is simple, straightforward and easy to use. As you use your Breeze System, you will appreciate the: • “no coding” of the test strips; • small sample volume; • fast reading time; • convenience of a 10-Test Disc; • sim

Summary of the content on the page No. 6

a l ook ta y our BrEEzE m EtEr : ReleaseButton Press to release and discard the used test strip. Screen This is where DataPor t your test results (side of meter) will be displayed. Insert cable here to allow communication Battery Holder between the (side of meter) meter and Holds one a personal CR2032 lithium computer. battery (included). Tabto Open Button Door On/Off Button Button Door Used to manually Open to expose turn the meter meter buttons.

Summary of the content on the page No. 7

Button Door Open On/Off Button Used to manually Up/ turn the meter Down on or off, check Buttons the number of Used to display strips, and check additional the date/time. results or options. Memory Button Accept Used to view your Button blood glucose Used to accept results stored in changes made memory and to in the Setup view your test mode. result averages. Setup Button Tab to Open Used to enter Button Door the Setup mode NOTE: Simply place the easy r

Summary of the content on the page No. 8

ExPtIlana on of d IsPyla s B ym ols : A full display, as shown here, indicates that all elements in the display are working properly. To view the full display, press and hold the On/Off button ( ) or pull the meter handle all the way out. Compare your meter to the display shown here before you run each test. If there is a difference, please see “Troubleshooting and Error Codes” on page 40. Here is what each display element means: Test result and error codes are displayed here The num

Summary of the content on the page No. 9

Here is what each display element means: Apply blood to Temperature is the test strip too high or too low Battery is Insert a new test disc low or dead The result is not to be included in the averages The volume of The result is a the buzzer control test 5 www.ascensia.ca

Summary of the content on the page No. 10

t EstIng m tErIals a : ® ® Ascensia Breeze 10-Test Disc (Disc contains ten test strips) (Not included) ® ® Ascensia Breeze Normal Control (Not included) ® ® Ascensia MicroLet Adjustable Lancing Device and Lancet (Included) 6 Bayer Diabetes Care Helpline: 1-800-268-7200

Summary of the content on the page No. 11

EvEryyda u sE InsErtIng a 10-t Est d Isc : WARNING: Never open the meter with the meter handle pulled out. Open Meter 1. Turn the meter over so the display screen is facing down. Open the meter by pressing down on the back edge of the open latch and then pulling up on the base. Open Test Disc Package 2. Open a new 10-Test Disc package. Check the expiration date on the disc. 7 www.ascensia.ca

Summary of the content on the page No. 12

Insert Disc 3. Insert a new 10-T est Disc (with the bumpy side up), aligning the 5 notches in the disc with the tabs on the meter. Close Meter 4. Close the meter and snap it shut. Keep the meter fl at when closing it. Helpful Hint: The meter must be kept fl at when closing. If the meter is not kept fl at, the disc may move and become damaged and you may waste test strips. 8 Bayer Diabetes Care Helpline: 1-800-268-7200

Summary of the content on the page No. 13

Counting the Number of Strips Left Your Breeze Meter will automatically count down the number of test strips you have left. The number is shown with your test result. To see the count when the meter is off, press the button. NOTE: This count is reset to 10 every time you open the meter. To keep an accurate count, open the meter only when all 10 of the test strips have been used in the 10-Test Disc. Your meter will also tell you when you need to insert a new 10-Test Disc. It will do

Summary of the content on the page No. 14

r unnIng a Blood g lucosE t Est : 1. Wash your hands well with soap and warm water. Rinse and dry thoroughly. Prepare Lancing Device 2. Remove the endcap from the MicroLet Adjustable Lancing Device. (See MicroLet Device package insert for complete instructions.) 3. Loosen the cap on a lancet by rotating it ¼ turn (do not remove). 0 Bayer Diabetes Care Helpline: 1-800-268-7200

Summary of the content on the page No. 15

Then insert the lancet fi rmly until it comes to a full stop. This will “cock” the device. 4. Twist off the lancet cap and replace the endcap. Push Out Test Strip 5. Your Breeze Meter uses a special, easy-to-use “Pull and Push” design. Here’s how it works: Hold the meter comfortably in one hand. Firmly grasp the meter handle with the other hand (shown here). Now, just “Pull and Push”—“Pull” the handle out until it stops and “Push” it back in until it stops again. Helpful Hint:

Summary of the content on the page No. 16

NOTE: After the meter handle is pushed in, the release button is UP, a test strip is pushed out, and a series of “apply blood” prompts appears. The meter is now ready to run a blood glucose test. CAUTION: • Y our meter is designed to push out one test strip at a time. Do not attempt to push out a new test strip with one already showing. • Discar d any test strip that has been removed from the meter. Never re-insert a test strip into the meter. 6. Stick your fi nger and form a small

Summary of the content on the page No. 17

Test 7. Your test strip is like a straw—it sips in a sample of blood. Move the entire front edge of the test strip until it touches the edge of the blood drop, without touching the fi nger. The blood is automatically pulled into the test strip and fi lls the test strip. Hold the test strip in place until the meter beeps, then move the meter away. For best results: • Blood is pulled IN the test strip, not dropped ON. • Do not allow blood to run down into the meter. • Do not add

Summary of the content on the page No. 18

8. After the beep, the display counts down from “5” to “1.” Your test result then appears on the screen. Helpful Hint: The number displayed in the upper left corner is the number of test strips remaining in your 10-test disc. IMPORTANT: If you want to mark this result as a deleted blood test, you must do that now, while the result is still being displayed. See “Marking a Deleted Blood Test” on page 17.  Bayer Diabetes Care Helpline: 1-800-268-7200

Summary of the content on the page No. 19

9. T o release the used test strip, hold the meter with the test strip pointing down over a waste container. Press the release button. Be sure the heel of your hand is not against the meter handle. NOTE: If you block the meter handle with your hand, the test strip may not release properly. 10. Press the button to turn the meter off. NOTE: If you forget to turn your meter off, it will turn off automatically after three minutes. This will save battery power. 5 www.ascensia.ca

Summary of the content on the page No. 20

PRECAUTIONS: • Test your blood again if your glucose result is below 2.8 mmol/L, above 13.9 mmol/L or if the meter shows “LO” or “HI.” If your glucose level is still below 2.8 mmol/L, above 13.9 mmol/L, or if the meter again shows “LO” or “HI,” it may indicate a potentially serious medical condition. If this is the case: Consult your physician or healthcare professional immediately. • Do not change your medication based on blood glucose results with yo


Alternative user manuals
# User manual Category Download
1 Bayer HealthCare Ascensia Contour User manual Blood Glucose Meter 267
2 Bayer HealthCare Ascensia Elite XL User manual Blood Glucose Meter 124
3 Bayer HealthCare Breeze 2 User manual Blood Glucose Meter 934
4 Bayer HealthCare Contour TS User manual Blood Glucose Meter 1516
5 Bayer HealthCare Ascensia Contour Blood Glucose Monitoring System User manual Blood Glucose Meter 42
6 Bayer HealthCare MODEL Ascensia Elite User manual Blood Glucose Meter 105
7 Bayer HealthCare CONTOURand Ascensia CONTOURTM Test Strips User manual Blood Glucose Meter 18
8 Bayer HealthCare Elite XL User manual Blood Glucose Meter 30
9 Bayer HealthCare Rapidlab 800 User manual Blood Glucose Meter 11
10 Bayer HealthCare ESPRIT User manual Blood Glucose Meter 22
11 Bayer HealthCare Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc User manual Blood Glucose Meter 50
12 A&D UA-1030TCN User manual Blood Glucose Meter 3
13 A&D UA-1030T User manual Blood Glucose Meter 4
14 Abbott Diabetes Care 7115 User manual Blood Glucose Meter 12
15 Abbott Diabetes Care FreeStyle Flash Blood Glucose Monitor User manual Blood Glucose Meter 106
16 Abbott Diabetes Care Blood Glucose Monitoring System ART21258 User manual Blood Glucose Meter 2