Nordyne Light Commercial Air Handler B5SM -090 user manual

User manual for the device Nordyne Light Commercial Air Handler B5SM -090

Device: Nordyne Light Commercial Air Handler B5SM -090
Category: Air Conditioner
Manufacturer: Nordyne
Size: 1.8 MB
Added : 5/22/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Nordyne Light Commercial Air Handler B5SM -090. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Nordyne Light Commercial Air Handler B5SM -090.

For your convenience

If looking through the Nordyne Light Commercial Air Handler B5SM -090 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Nordyne Light Commercial Air Handler B5SM -090 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Nordyne Light Commercial Air Handler B5SM -090 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Nordyne Light Commercial Air Handler B5SM -090 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Nordyne Light Commercial Air Handler B5SM -090 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Nordyne Light Commercial Air Handler B5SM -090. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

B5SM -090/120 SERIES
Installation Instructions
LIGHT COMMERCIAL AIR HANDLER
Vertical Application
Horizontal Application - Rear View Horizontal Application - Front View
IMPORTANT
Please read this information thoroughly and become familiar with the capabilities and
use of your appliance before attempting to operate or maintain this unit. Keep this
literature where you have easy access to it in the future. If a problem occurs, check the
instructions and follow recommendations given. If these sug

Summary of the content on the page No. 2

Important Safety Information ....................................3 General Information ...................................................4 Before You Install this Unit .........................................4 Locating the Air Handler ............................................4 Field Connections for Electrical Power Supply ..........4 Air Ducts ....................................................................4 Unconditioned Spaces ...........................................4 Acousti

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION Safety markings are used frequently throughout this WARNING: manual to designate a degree or level of seriousness and The safety information listed below must should not be ignored. WARNING indicates a potentially be followed during the installation, service, hazardous situation that if not avoided, could result in and operation of this unit. Unqualified personal injury or death. CAUTION indicates a potentially individuals should not attempt to interpret the

Summary of the content on the page No. 4

GENERAL INFORMATION Air Ducts This unit is designed only for use with a supply B5SM air handlers are shipped from the factory ready for and return duct. Air ducts should be installed in installation in a horizontal position. The units can be easily re- accordance with the standards of the National Fire confi gured in the fi eld for vertical applications. The return air Protection Association Standard for Installation of opening is interchangeable between the bottom of the unit and Air Condi

Summary of the content on the page No. 5

AIR HANDLER INSTALLATION Connecting Refrigerant Tubing Packaging Removal Remove the shipping crate and User’s Manual from the WARNING: equipment. T ake care not to damage the tubing connections when removing the crate. NITROGEN HEALTH Minimum Clearance Requirements 1 This air handler must be installed with ample clearance FLAMMABILITY 0 for easy access to the air fi lters, blower assembly, and, controls. Allow 24 inches minimum clearance from the REACTIVITY 0 front of the motor and refriger

Summary of the content on the page No. 6

� The B5SM-120 air handler has a dual circuit coil and 6. Re-install the fi lter slide assembly back into the fi lter rack the B5SM-090 has a single circuit coil. frame and secure with the 4 screws removed earlier. If � The B5SM-120 air handler is charged through service replacing factory supplied fi lters with disposable fi lters, valves on the end of the liquid tube for each circuit. use only 2” disposable fi lters. These must be removed before brazing the line sets. Accessing the fi lters does

Summary of the content on the page No. 7

ELECTRICAL WIRING schematic before making any electrical connections to the unit. See Figure 6 (page 13). � These air handlers can be purchased in both single WARNING: and three phase power confi gurations, all single phase To avoid risk of electrical shock, personal equipment is shipped from the factory ready for fi eld connections. For electrical connection locations see injury, or death, disconnect all electrical power Figures 4 or 5 (pages 10 or 11). to the unit before performing any ma

Summary of the content on the page No. 8

Unbalanced 3-Phase Supply Voltage Grounding Voltage unbalance occurs when the voltages of all phases of a 3-phase power supply are no longer equal. This WARNING: unbalance reduces motor effi ciency and performance. The unit cabinet must have an uninterrupted or Some underlying causes of voltage unbalance may include: unbroken electrical ground to minimize personal Lack of symmetry in transmission lines, large single-phase loads, and unbalanced or overloaded transformers. A injury if an el

Summary of the content on the page No. 9

Pulley Alignment necessary to change the factory set speed. Adjustment Inspect the pulley alignment between the motor sheave of the blower speed is made through varying the pitch of and blower pulley. If a misalignment occurs, adjust the the motor pulley, this adjustment allows for a wide range location of the motor sheave by loosening the set-screw of installation applications. Refer to Table 4 (page 12) for in the stationary face of the motor sheave. Relocate the blower performance data. s

Summary of the content on the page No. 10

FIGURES & TABLES 3/4" Field Installed Hanging Rods 1 1/4" 47 5/8" Center to Center 2 7/32" C 23 13/16" of Unit L C 1" of Gravity L Electrical Connections Electrical Connections Air Flow Air Flow 13 5/8" 8 3/16" 6 3/4" 15 11/16" 15 9/16" 5 11/16" 4 3/4" 17 11/16" 4 3/8" 7 1/2 Ton Unit Refrigerant Line Connections 17 13/16" 4 3/16" (Top View Shown with Doors Removed) 10 Ton Unit Refrigerant Line Connections (Top View Shown with Doors Removed) Field Installed Hanging Rods 57" Center to Center C 28

Summary of the content on the page No. 11

18 13/16" 19 3/8" 22 1/16" Supply Duct 16 1/4" Electrical Knock-outs Top View 27 3/8" Cabinet Depth (without Filter Rack) 60 1/4" Cabinet Width 16 1/4" Supply Duct Opening 18 13/16" Supply 19 3/8" 22 1/16" Duct Opening 9 1/8" 2 Electrical Connections 53 1/4" Cabinet Height 25 1/16" 23" Return Filter Rack Duct Opening Frame Condensate 5 1/16" Drain 29 5/16" Depth 53" Return Duct Opening (with Filter Rack) 57" Filter Rack Frame Front View Side View Figure 5. B5SM Physical Dimensions for Vertical

Summary of the content on the page No. 12

AIRFLOW DATA Table 4. Blower Performance Data 12 External Static Pressures (Inches Water Column) Motor Model Sheave 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Position CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw Fully 4182 666 1.28 3961 667 1.20 3706 668 1.11 3436 669 1.03 3081 669 0.93 2738 672 0.83 Closed 1 Turn 3867 629 1.09 3638 630 1.01 3366 631 0.95 3055 632 0.85 2672 633 0.77 Open B5SM- 2 Turns 090 3268 592 0.82 3074 593 0.80 2783 593 0.74

Summary of the content on the page No. 13

460 208-230 460 208 - 230 ELECTRICAL INFORMATION Figure 6. Wiring for Single and Three Phase Units 13 B5SM Series Electrical Configurations Frequency Single Phase Three Phase 7.5/10T Air Handler Systems 60 Hz 208-230V 208-230/460V GENERAL NOTES: 50 Hz 220V 380V 1. Disconnect all power before servicing. 2. If wiring must be replaced, use only THREE PHASE ONLY NOTES: 105˚C copper wire of the same gauge. 1. Three phase units are factory wired for 3. Three phase, 60 Hz units may be 3. For e

Summary of the content on the page No. 14

NOTE: C &W2 to be connected to electric heat. TO FIELD SUPPLIED DISCONNECT GND SINGLE STAGE HEAT/COOL THERMOSTAT L1 RC W G Y L2 L3 BLOWER MOTOR FREEZESTAT GREEN BROWN G BLACK C C See Note W2 W1 O Y Y BLACK R R TERMINAL BOARD AIR HANDLER SECTION OUTDOOR SECTION SINGLE STAGE HEAT/COOL THERMOSTAT- NO ECONOMIZER NOTES: 1. C & W2 to be connected to electric heat. 2. Remove BLACK wire from air handler low voltage terminal board Y terminal and connect to YELLOW wire from economizer. 3. 2nd Stage re

Summary of the content on the page No. 15

NOTES: TO FIELD 1. Jumper between W2 and E is required. SUPPLIED DISCONNECT 2. C &W2 to be connected to electric heat. GND SINGLE STAGE HEAT PUMP THERMOSTAT L1 R O W2 E C G Y B L2 L3 NOTE 1 BLOWER MOTER FREEZESTAT BROWN GREEN G BLACK C C W2 W2 O O NOTE 2 R R BLACK Y Y W1 TERMINAL BOARD AIR HANDLER OUTDOOR SECTION SECTION TYPICAL HEAT PUMP THERMOSTAT CONNECTION (NO ECONOMIZER) NOTES: 1. Jumper between W2 and E is required. 2. C & W2 to be connected to electric heat. 3. Remove BLACK wire from air

Summary of the content on the page No. 16

Installed by: Date Installed: Maintenance Task Performance Date Performed: Schedule WM SA A Air Filters Inspect, clean or replace as required. x Condensate Drain(s) & Pan Clean condensate drain pan x Inspect the flow of condensate through x the drain lines. Clean or Correct problems as necessary. Blower Assembly Inspect the fan belt for wear, alignment x & and proper tension. Replace or adjust as required. Clean the blower wheel and housing. x x Inspect the blower assembly for corrosion an


Alternative user manuals
# User manual Category Download
1 Nordyne Forced Air Gas and Oil Furnace M1M User manual Air Conditioner 7
2 Nordyne E3 User manual Air Conditioner 2
3 Nordyne Forced Air Gas and Oil Furnace M1B User manual Air Conditioner 1
4 Nordyne Forced Air Gas and Oil Furnace M1S User manual Air Conditioner 0
5 Nordyne Forced Air Gas and Oil Furnace M1G User manual Air Conditioner 0
6 Sony SU-PW2 User manual Air Conditioner 12
7 Sony CV-P12PX User manual Air Conditioner 3
8 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
9 Sony VGN-BX500 User manual Air Conditioner 1
10 Philips 190S5 User manual Air Conditioner 21
11 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
12 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
13 Philips CS-E15DB4EW User manual Air Conditioner 4
14 Philips GOGEAR SA3425 User manual Air Conditioner 1
15 Philips 3160 User manual Air Conditioner 7