Omega OSP SERIES user manual

User manual for the device Omega OSP SERIES

Device: Omega OSP SERIES
Category: Thermometer
Manufacturer: Omega
Size: 0.72 MB
Added : 3/19/2013
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega OSP SERIES. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega OSP SERIES.

For your convenience

If looking through the Omega OSP SERIES user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega OSP SERIES on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega OSP SERIES to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega OSP SERIES User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega OSP SERIES but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega OSP SERIES. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

http://www.omega.com
e-mail: info@omega.com
OSP SERIES
Portable IR thermometers

Summary of the content on the page No. 2

SM OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: One Omega Drive, Box 4047 USA: Stamford, CT 06907-0047 ISO 9001 Certified Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com 976 Bergar Canada: Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: SM Usa and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Customer Service: 1-800-622-2378 /

Summary of the content on the page No. 3

INTRODUCTORY NOTE This user’s guide contains operating instructions, as well as a description of the principles of operation, of the OSP Series portable IR thermometers. This information covers all models of the instrument, including the basic equipment and its options and accessories. This manual is a complete “USER GUIDE”, providing step-by-step instructions to operate the instrument in each of its designed functions. OMEGA has used care and effort in preparing this guide and believes the i

Summary of the content on the page No. 4

TABLE OF CONTENTS 1 GENERAL DESCRIPTION................................................................................................................... 6 1.1 Instrument codes..............................................................................................................................................7 1.2 Specifications ...................................................................................................................................................8 2 GENERAL F

Summary of the content on the page No. 5

11 DATA ACQUISITION OPERATIVE MODE........................................................................................ 32 11.1 How to operate in data acquisition mode........................................................................................................32 11.2 Recall stored data...........................................................................................................................................34 12 LOGGING DATA MANAGER ..................................

Summary of the content on the page No. 6

1 GENERAL DESCRIPTION Portable infrared thermometers measure surface temperature without touching the surface. They collect the infrared energy radiated by a target and compute its surface temperature. OMEGA OSP Series are portable infrared temperature devices designed to ease maintenance operations. They also enable the monitoring of operating temperatures of mechanical and electrical plants or production equipment without removing the equipment from the service. Any temperature variation notic

Summary of the content on the page No. 7

1.1 Instrument codes To Order Model No. Temperature Spectral Target Spot Size D/S Optical Ratio Range Response @ Distance ** –30 °C to +930 °C 10mm @ 600mm 60:1 OSP500-(*) 8 to 14 µm -20°F to +1706°F 0.39 @ 24” –30 °C to +930 °C 8 to 14 µm 10mm @ 600mm 60:1 OSP800-(*) -20°F to +1610°F 0.39 @ 24” OSP1000-(*) –30 °C to +1000 °C 8 to 14 µm 10mm @ 1000mm 100:1 -20°F to +1830°F 0.39 @ 39.4” OSP1300-(*) +300 °C to +1300 °C 1.6 µm 6mm @ 1000mm 167:1 +570°F to 2370°F 0.236 @ 39.4” +600 °C to +1600 °C 5m

Summary of the content on the page No. 8

1.2 Specifications Target dimensions at different distances • Temperature measuring ranges: -30 to 2000°C (-22 to 3632°F) • Thermocouple measuring ranges: type K : -100°C to +1370°C (-148 to 2500°F) 0.1°C resolution type S : 0°C to +1760°C (-32 to 3200°F) 0.1°C resolution • Spectral response: OSP 500, 800 & 1000 : 8 - 14 µm OSP 1300 : 1.6 µm OSP 1600 & 2000 0.9 µm • Accuracy: OSP 500, 800 & 1000: ±(1% of the reading +1°C/2°F) OSP 1300, 1600 & 2000: ±(0.5% of the reading +1°C/2°F) • Repeatabili

Summary of the content on the page No. 9

2 GENERAL FEATURES 2.1 General Temperature measurements of a liquid or gaseous compound have been successfully made with thermoelectric or expansion thermometers thanks to the good thermal exchange of the sensor with the fluid. With solid bodies a good thermal exchange is difficult to be obtained and an additional measuring error should be considered. A direct contact measurement is impractical when the object being measured is moving, it cannot be touched with a thermoelectric sensor because of

Summary of the content on the page No. 10

2.5 Keyboard Traditional metal-click switches, with a working life of one million operations, are used to enter the operator’s instructions. The contact closure of the keyboard keys is acknowledged, as a coded signal, directly by the microcontroller. 2.6 Display The high contrast customised alphanumeric LCD display indicates the measured temperature value. It is also used for operators’ messages, instrument configuration set-up, special operative modes, etc. It is equipped with a backlight devic

Summary of the content on the page No. 11

In this case the instrument can be powered directly from mains using the external power supply module supplied with the thermometer. 2.11 Logging Mode The instrument can be equipped with an internal memory to store up to 500 input data. Two types of data acquisitions can be selected by the user. Continuous acquisition The operator can select the interval time between each acquisition and store progressively the input data in the Tag file or can manually, step by step, give the acquisition instru

Summary of the content on the page No. 12

3 PHYSICAL DESCRIPTION OSP portable IR thermometers consist of a rugged, compact and self-extinguishing case ergonomically designed for an easy practical use. The instrument can be supplied either with a vinyl protective case with shoulder strap or with an aluminum case to assure better protection against mechanical knocks or scratches. The battery container is located on the lower part of the handle, and is accessible through a cover fastened by a metal screw. 12

Summary of the content on the page No. 13

4 FUNCTIONAL DESCRIPTION OSP series infrared portable thermometers block diagram is shown below: Analog Output Detector Emitted IR energy A/D Micro- LCD Amplifier converter controller display Measuring Filter Tc object Keyboard Digital Auxiliary interface input Optical system • Optical system Filter • • Detector Amplifier • • A/D converter • Microcontroller • LCD display • Digital interface • Keyboard • Tc auxiliary input (optional) • Analog output (optional) The radiated infrared energy is f

Summary of the content on the page No. 14

4.3 Microcontroller The microcontroller handles all the logic functions of the instrument, performs the linearization for non linear transducers, compensates for the reference junction temperature, drives the digital display and acknowledges all the operator’s instructions. The core of the circuit is a single-chip microcomputer that utilizes HCMOS technology to provide the low power characteristics and high noise immunity of CMOS plus the high speed operation of HMOS. The microcomputer provides

Summary of the content on the page No. 15

5 UNPACKING Remove the instrument from its packing case and remove any shipping ties, clamps, or packing materials. Carefully follow any instruction given on any attached tags. Inspect the instrument from scratches, dents, damages to case corners etc. which may have occurred during shipment. If any mechanical damage is noted, report the damage to the shipping carrier and then notify OMEGA directly or its nearest agent, and retain the damaged packaging for inspections. A label indicates the seri

Summary of the content on the page No. 16

6 PRE-OPERATIONAL CHECK OSP series portable thermometers are powered either by four alkaline or by Ni-MH rechargeable batteries (optional). The external battery charger, supplied as a standard , is set for 115Vac power source. Before using the instrument carefully verify the nominal voltage value of the charger with the available mains power line. The instrument should be used in environments where the temperature does not exceed the specified limits (from -5°C to +50°C) and where the relative h

Summary of the content on the page No. 17

7 POWER SUPPLY The instrument may be powered by alkaline or rechargeable batteries or directly from the main line. OSP uses 4 batteries type AA that are located inside the base of the handle. 7.1 Rechargeable batteries The rechargeable batteries are shipped with an average level of charge. After unpacking, a full charge of the batteries is recommended. Connect the instrument to the charger module (“OFF” condition) for a period of 10 hours minimum. The Ni-MH rechargeable batteries do not suffer w

Summary of the content on the page No. 18

8 WARNINGS & CAUTIONS 8.1 Laser Sight You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MAY RESULT IN HAZARDOUS RADIATION EXPOSURE. • DO NOT LOOK AT THE LASER BEAM COMING OUT OF THE LENS OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS – EYE DAMAGE CAN RESULT. • USE EXTREME CAUTION WHEN OPERATING THE LASER. • NEVER POINT THE LASER BEAM AT A PERSON. • KEEP OUT O

Summary of the content on the page No. 19

19

Summary of the content on the page No. 20

9 OPERATIONS OSP series portable infrared thermometers are factory calibrated before shipment. During the start-up the operator should only select and load, if required, the pertinent application parameter as described in the following paragraphs. Before entering the procedure to operate the instrument it is useful the understanding of the messages that can be present in the display. The following figure shows the overall layout of the display and an explanation of each symbol or message : 4 7


Alternative user manuals
# User manual Category Download
1 Omega 25 User manual Thermometer 1
2 Omega A12P User manual Thermometer 0
3 Omega CL24 User manual Thermometer 4
4 Omega CL25 User manual Thermometer 5
5 Omega 27 User manual Thermometer 0
6 Omega CL27 User manual Thermometer 6
7 Omega CL23A User manual Thermometer 30
8 Omega CL26 User manual Thermometer 4
9 Omega 26 User manual Thermometer 0
10 Omega CL3512A User manual Thermometer 19
11 Omega DP1001M User manual Thermometer 0
12 Omega DP751 User manual Thermometer 0
13 Omega DP119-RTD User manual Thermometer 0
14 Omega DPG110/120 User manual Thermometer 1
15 Omega HH370 User manual Thermometer 1
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3