Omega Engineering HH505 user manual

User manual for the device Omega Engineering HH505

Device: Omega Engineering HH505
Category: Thermometer
Manufacturer: Omega Engineering
Size: 0.32 MB
Added : 4/26/2013
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega Engineering HH505. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega Engineering HH505.

For your convenience

If looking through the Omega Engineering HH505 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega Engineering HH505 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega Engineering HH505 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega Engineering HH505 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega Engineering HH505 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega Engineering HH505. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OMEGA
HH505
Digital Thermometer

Summary of the content on the page No. 2

TM omega.com SM OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: SM SM Sales Service: 1-800-826-6342 / 1-800-TC-OM

Summary of the content on the page No. 3

INTRODUCTION This instrument is a 4½ digit, compact-sized portable digital thermometer designed to use external 100W Platinum RTD as temperature sensor. Tem- perature indication follows Reference Temperature/Resistance Tables (Pt385 for European Curve, Alpha=.00385 and Pt3926 for American Curve, Al- pha=.003926). SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the thermometer. WARNING To avoid electrical shock, do not use this instrument whe

Summary of the content on the page No. 4

SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable. Measurement Range: Pt385(100W ) -200°C to 800°C, (-328°F to 1472°F) Pt3926(100W ) -200°C to 630°C, (-328°F to 1166°F) Resolution: 0.1°C or 0.2°F Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not including RTD probe error. ±(0.05% rdg + 0.2°C) on °C scale ±(0.05% rdg + 0.4°F) on °F scale Temperature Coefficient: 0.1 times the applicable accura

Summary of the content on the page No. 5

ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 4½ digit liquid crystal display (LCD) with maximum reading of 19999. Overload: "----.-" is display. Battery: Standard 9V battery. Battery Life: 100 hours typical. Auto power off: The meter key switch inactive for more than 30 minutes, press power key to resume operation. Dimensions: 192mm(H) x 91mm(W) x 52.5mm(D). Weight: 365g. 3

Summary of the content on the page No. 6

OPERATING INSTRUCTIONS 1 Power Switch The key turns the thermometer on or off. In the data SET mode, can not power off, must leave data SET mode then power off. 2 °C/°F Selecting the Temperature Scale (Main display) Reading the main displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the °C/°F key. 3 HOLD Mo

Summary of the content on the page No. 7

5 Pt385/Pt3926 T1 Input RTD Probe Select The Pt385/Pt3926 key switch the T1 input selects the Pt385 or Pt3926 RTD probe as input. When the thermometer is turned on, it is set to the probe selected that was in use when the thermometer was last turned off. MIN MAX with Time record Mode 6 Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading with time, Minimum reading with time and Average reading stored in record mode). In the this mode the automatic power-off featu

Summary of the content on the page No. 8

7 REL Relative mode Pressing REL key to enter the Relative mode, zero the display, and store the displayed Reading as a reference value and annunciator REL is displayed. Present temperature reading displayed on second display. Press REL key again to exit the relative mode. The relative value can also be entered by the user. (See "SET mode" later in this manual.) When the desired Relative value has been entered, press REL key to enter the Relative mode, press SET key use set Relative value as a r

Summary of the content on the page No. 9

9 SET mode (Relative value set, Time set and Hi/Lo Limits value set) 1. Press SET key to enter Relative valuse SET mode (Press ENTER key can escape relative valuse set mode), REL set mode. = = = =.= is displayed in main display. Relative value is entered via overlay numbers, then press overlay ENTER key, stored the relative value, enter Time set mode. 2. Time set mode, (Press ENTER key can escape Time set mode) =.= = = : = = is displayed in second and third display. Time (hours, minutes, second

Summary of the content on the page No. 10

10 Hi Limit value Recall display mode Press Hi RECALL key to display the Hi set Limit value on second display. Press Hi RECALL key again to exit this mode. Lo Limit value Recall display mode 11 Press Lo RECALL key to display the Hi set Limit value on second display. Press Lo RECALL key again to exit this mode. Hi/Lo Limits mode (only Main display) 12 Press Hi/Lo Limits key to enter the Hi/Lo Limits comparative mode, when input temperature value exceed Hi or Lo Limits value. The beeper emits a

Summary of the content on the page No. 11

OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the rmometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two screws from the back of the meter and lift off the battery cover. Remove the battery from battery contacts. RTD PROBE CONNECTION P/N : 17650-0505 RW1 + G RTD 100W + RW2 - Pt385

Summary of the content on the page No. 12

TEMPERATURE VS RESISTANCE TABLE(ITS90) °C Pt385 Pt3926 -200°C 18.521W 16.996W -100°C 60.256W 59.479W 0°C 100.000W 100.000W 100°C 138.505W 139.272W 200°C 175.856W 177.362W 300°C 212.052W 214.275W 400°C 247.092W 250.018W 500°C 280.977W 284.591W 600°C 313.708W 317.994W 700°C 345.280W - 800°C 375.700W - 10

Summary of the content on the page No. 13

HH 504 / HH 505 CALIBRATION PROCEDURE Note: The following calibration procedure should perform only by qualified technicians who have access to the items as following. Equipment: The class of calibrator had better 10 times greater than the measured meter. 1. Turn off the meter then set the adjusted jumper to J1. 2. Insert the 383.00Ω calibrator to the T1 then turn on the meter, the main display reading reads 1830.0 then press " ENTER " key. 3. The second display is stabilized (about 5sec.), then

Summary of the content on the page No. 14

WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product.If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Departme

Summary of the content on the page No. 15

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE DATA ACQUISITION þ Thermocouple, RTD & Thermistor þ Data Acquisition & Probes, Connectors, Panels & Assemblies Engineering Software þ Wire: Thermocouple, RTD & Thermistor þ Communications-Based þ Calibrators & Ice Point References Acquisition Systems þ Recorders, Controllers & Process Monitors þ Plug-in Cards for Apple, IBM þ Infrared Pyrometers & Compatibles þ Datalogging Systems PRESSURE/STRAI


Alternative user manuals
# User manual Category Download
1 Omega Engineering CYD218 User manual Thermometer 2
2 Omega Engineering HH-25 User manual Thermometer 1
3 Omega Engineering HH-2100 User manual Thermometer 0
4 Omega Engineering FSW-50 User manual Thermometer 0
5 Omega Engineering DP95 User manual Thermometer 0
6 Omega Engineering HH12B User manual Thermometer 20
7 Omega Engineering HH147 User manual Thermometer 5
8 Omega Engineering DP251 User manual Thermometer 0
9 Omega Engineering HH501AJK User manual Thermometer 4
10 Omega Engineering HH306 User manual Thermometer 3
11 Omega Engineering HH501BR User manual Thermometer 0
12 Omega Engineering HH502 User manual Thermometer 4
13 Omega Engineering HH504 User manual Thermometer 3
14 Omega Engineering GP901 User manual Thermometer 2
15 Omega Engineering HH507R User manual Thermometer 0
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3