Emerson 37E73A-906 user manual

User manual for the device Emerson 37E73A-906

Device: Emerson 37E73A-906
Category: Thermostat
Manufacturer: Emerson
Size: 1.98 MB
Added : 2/17/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 37E73A-906. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 37E73A-906.

For your convenience

If looking through the Emerson 37E73A-906 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 37E73A-906 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 37E73A-906 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 37E73A-906 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 37E73A-906 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 37E73A-906. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

37E73A-903 & 906 INTELLI-VENT™
Water Heater Thermostat Control
Installation Instructions
For Natural Gas Only
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 37E73A-903/906 INTELLI-IGNITION™ control is a
combination gas valve, ignition control, and thermostat for
use on Power Vented water heaters. The microcomputer in
the co

Summary of the content on the page No. 2

SPECIFICATION ELECTRICAL RATINGS: Automatic High Temperature Cutoff: o o Single-Use Type, 185 F(82 C) Input and Frequency: 120 VAC, 60 Hz Output Ratings: Prepurge Time: 5 Seconds Ignitor Load: 2 Amps maximum Ignitor Warm-up Time: 20 Seconds Inducer Draft Motor: 3 Amps Full Load, 4 Amps Locked Trial for Ignition Period: 4 Seconds Rotor Inter-purge Time: 5 Seconds Current: 0.2 Amps @ 120 VAC Post-purge Time: 5 Seconds Range of Regulation (Btu/Hr) Minimum: 30,000

Summary of the content on the page No. 3

INSTALLATION 5. For a brief (one to five seconds) all of the indicators on CAUTION ! the front of the control should come on, and then turn off. This indicates that the control has completed the Never use this water heater unless it is completely self-diagnostic test, and is ready for operation. If any filled with water. To prevent damage to the tank, the combination of indicators remain illuminated, either refer tank m ust be filled with water . W ater m ust flo w fr om to th

Summary of the content on the page No. 4

INSTALLATION Press and release the HOTTER button until you have WARNING ! reached the desired setting. HOLDING DOWN THE BUTTON WILL NOT CONTINUE TO RAISE THE SETTING. The button Never allow small children to use a hot water tap, or must be pressed and released for each temperature change to draw their own bath water. Never leave a child or desired. impaired person unattended in a bathtub or shower. Scald burns can result To avoid scald injury, set the control to the lowest setting wh

Summary of the content on the page No. 5

WIRING DIAGRAM A typical system wiring diagram is shown below. Use the installation. Always follow the instructions supplied with the water heater manufacturer’s wiring diagram for details of the water heater, and those of the water heater manufacturer. ™ Intelli-Vent Wiring Diagram Typical Installation (Consult Appliance Manufacturer's Instructions For Details) TM INTELLI-VENT CONTROL BOTTOM VIEW INSET FLAMMABLE VAPOR SENSOR (IF EQUIPPED) IGNITOR AND FLAME PROBE ASSEMBLY BLACK WHITE

Summary of the content on the page No. 6

SEQUENCE OF OPERATIONS APPLY POWER TO APPLIANCE Intelli-Vent™ Sequence of Operation NO DISPLAY ERROR CODE IS FIELD WIRING CORRECT? 1 OR 2 YES NO REQUEST FOR HEAT PRESENT? YES IS WAIT FOR PRESSURE IS WAIT FOR PRESSURE NO NO PRESSURE SWITCH SWITCH TO OPEN PRESSURE SWITCH SWITCH TO OPEN PROVEN OPEN WITHIN DISPLAY ERROR PROVEN OPEN WITHIN DISPLAY ERROR 5 SECONDS? NUMBER 3 5 SECONDS? NUMBER 3 YES YES COMBUSTION COMBUSTION BLOWER ON BLOWER ON ONE HOUR AUTO LOCKOUT RESET DELAY IS IS WAIT FOR PRESSURE

Summary of the content on the page No. 7

SEQUENCE OF OPERATIONS TROUBLESHOOTING The troubleshooting charts cover the error codes that the perature setting (see section “Temperature Regulation”). TM Intelli-Vent control can recognize, the potential cause, and If you have noted an error code from a previous heating those actions that may help repair the problem. The water cycle, this step is not necessary, and you may proceed heater manufacturer’s troubleshooting procedure should be with the next step. consulted before attempting t

Summary of the content on the page No. 8

TROUBLESHOOTING The self diagnostic test 1. Cycle power to the water heater off for 10 seconds A B C 7 found a problem with the and then back on. gas valve driver circuit 2. If the above step did not cleat the error, the INTELLI-VENT™ control must be replaced The self diagnostic test has 1. Cycle the external power off for 10 seconds and A B C 8 detected a problem with then back on. the internal microcomputer. 2. If the above step does not clear the error, the INTELLI-VENT™ control must


Alternative user manuals
# User manual Category Download
1 Emerson 1F97-391 User manual Thermostat 23
2 Emerson 80 Series User manual Thermostat 28
3 Emerson 1F80-0471 User manual Thermostat 44
4 Emerson DISPLAY CASE AND COLD ROOM CONTROLLER EC2-391 User manual Thermostat 73
5 Emerson 90 SERIES 1F95-391 User manual Thermostat 49
6 Emerson 1A11-2 User manual Thermostat 4
7 Emerson EC2-311 User manual Thermostat 62
8 Emerson 1A65 User manual Thermostat 0
9 Emerson 1E78-140 User manual Thermostat 81
10 Emerson 1E78-144 User manual Thermostat 116
11 Emerson 1F78-144 User manual Thermostat 101
12 Emerson 1A65W User manual Thermostat 0
13 Emerson 1E78-151 User manual Thermostat 61
14 Emerson 1F78-151 User manual Thermostat 54
15 Emerson 1F80ST-0471 User manual Thermostat 45
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2