Honeywell CHRONOTHERM III T8611G user manual

User manual for the device Honeywell CHRONOTHERM III T8611G

Device: Honeywell CHRONOTHERM III T8611G
Category: Thermostat
Manufacturer: Honeywell
Size: 0.48 MB
Added : 4/12/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell CHRONOTHERM III T8611G. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell CHRONOTHERM III T8611G.

For your convenience

If looking through the Honeywell CHRONOTHERM III T8611G user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell CHRONOTHERM III T8611G on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell CHRONOTHERM III T8611G to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell CHRONOTHERM III T8611G User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell CHRONOTHERM III T8611G but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell CHRONOTHERM III T8611G. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TRADELINE
T8611G,R
Chronotherm III
Fuel Saver Thermostats
The AUX. HT., EM. HT., and CHECK LEDS are located
Application
near the bottom center of the subbase. See Table 1. The AUX.
These thermostats provide energy saving control for a 24
HT. LED lights whenever the thermostat is calling for
Vac multistage heat pump heating/cooling system as indi-
operation of the backup or auxiliary heater. Backup (auxil-
cated in Table 1 and are powered directly from the control
iary) heat is more expensive to

Summary of the content on the page No. 2

SYSTEM FAN ON AUTO EM. HT. HEAT OFF AUTO COOL AUX. HEAT CHECK by— Fig. 2—Mounting subbase on wall. —drafts or dead spots behind doors, in corners or under cabinets. —hot or cold air from ducts. WALL —radiant heat from sun or appliances —concealed pipes and chimneys. WIRES THROUGH WALL —unheated (uncooled) areas behind the thermostat, such WALL OPENING ANCHORS as an outside wall. (2) IF REPLACING AN EXISTING THERMOSTAT Turn off power to thermostat at furnace or heat pump. A two-transformer syste

Summary of the content on the page No. 3

Fig. 4—T8611G 2-stage heat/1-stage cool thermostat. 1 L1 L2 (HOT) 2 R POWER SUPPLY HIGH LIMIT C/X EM. HEAT AUX. HEAT LED (GRN) LED (RED) L FAN SWITCH MONITOR ON W2 SUBBASE AUTO HEAT 2 THERMOSTAT LOGIC/ AUXILIARY LOGIC CONTROL HEAT RELAY CIRCUIT CIRCUIT E EMERGENCY HEAT RELAY SYSTEM SWITCH EM. HT. G HEAT FAN RELAY OFF C.O. O AUTO CHANGEOVER COOL C.O. RELAY (COOL) B HIGH LIMIT CHANGEOVER COOL HEAT 1 RELAY (HEAT) Y COMPRESSOR CONTACTOR 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PR

Summary of the content on the page No. 4

Fig. 5—T8611R 2-stage heat/1-stage cool thermostat. 1 L1 L2 (HOT) 3 R POWER HIGH SUPPLY LIMIT C/X AUX. HEAT EM. HEAT LED (GRN) LED (RED) L FAN SWITCH MONITOR ON W2 SUBBASE AUTO THERMOSTAT LOGIC/ AUXILIARY HEAT 2 LOGIC HEAT RELAY CONTROL CIRCUIT CIRCUIT E EMERGENCY HEAT RELAY SYSTEM W1 SWITCH STAGE 1 HEAT RELAY EM. HT. G HEAT FAN RELAY OFF 2 O COOL CHANGEOVER RELAY (COOL) B HIGH CHANGEOVER LIMIT HEAT 1 RELAY (HEAT) Y1 COOL COMPRESSOR CONTACTOR P POWER SUPPLY. PROVIDE DISCONNECT MEANS AND

Summary of the content on the page No. 5

Fig. 6—T8611R 2-stage heat/1-stage cool thermostat. Exact replacement for York model no. 2ET11700224. R L1 POWER (HOT) 1 HIGH SUPPLY LIMIT L2 5 B TRANSFORMER EM. HEAT 3 LED (RED) X FAN MONITOR SWITCH ON W2 SUBBASE THERMOSTAT LOGIC/ 4 AUXILIARY AUTO LOGIC CONTROL HEAT 2 HEAT RELAY CIRCUIT CIRCUIT E EMERGENCY HEAT RELAY SYSTEM W1 SWITCH STAGE 1 HEAT RELAY EM. HT. G HEAT FAN RELAY OFF 2 O AUTO CHANGEOVER RELAY (COOL) H HIGH CHANGEOVER LIMIT HEAT 1 COOL RELAY (HEAT) Y1 COMPRESSOR CONTACTOR 1

Summary of the content on the page No. 6

When the batteries are low, the display will flash REPL Fig. 9—Mounting the thermostat on subbase. BAT. Homeowner will have 20-30 seconds to replace batter- ies after removing batteries from thermostat. After 20-30 seconds, it will be necessary to reprogram. REPL BAT indication will be disappear when thermostat is mounted back on the powered subbase. MOUNTING THE THERMOSTAT With system switch set to OFF, hang the thermostat on the tabs at the top of the subbase (Fig. 9A). Swing down and press on

Summary of the content on the page No. 7

Perform the following test as a check of all thermostat System Press Look for this functions. If thermostat does not respond as indicated, ther- Switch This Response mostat must be replaced. 1. Press AHEAD and BACK keys at the same time. Position Key Key Down Key Released While holding keys down, all segments of the display should CHANGE OFF 03 Blank TO LAST be on, see Fig. 10. PERIOD 2. Set system switch to OFF. Press AHEAD and BACK SKIP 07 Blank NEXT and PRESENT SETTING keys at the same time t

Summary of the content on the page No. 8

4-DIGIT CODE EXPLANATION Second Clock Digit (Hrs.) Degrees Cycle Rate Setting 012 F First (CPH at 50% on time, 112 C Digit 2nd stage heat) 424 F 0 or 2 6 524 C 4 or 6 3 M 524 Third System System Digit Switch Position Fourth Thermostat Switch Digit Type No. Position 0 HEAT, EM.HT, or OFF 0R COOL, OFF 2 AUTO 1G COOL, 4 COOL AUTO or OFF 2R EM.HT. or HEAT 3G AUTO, EM.HT. or HEAT Refer to Owner’s Manual for programming instructions and homeowner troubleshooting. This equipment is a Class B digital ap


Alternative user manuals
# User manual Category Download
1 Honeywell 191108AJ User manual Thermostat 629
2 Honeywell 42011076-003 User manual Thermostat 204
3 Honeywell 69-0786-2 User manual Thermostat 57
4 Honeywell 69-1776EFS-01 User manual Thermostat 56
5 Honeywell 72838 User manual Thermostat 42
6 Honeywell 69-2485EFS-03 TH8320ZW1000 User manual Thermostat 48
7 Honeywell 5-2-DAY DELUXE RTH6300B User manual Thermostat 50
8 Honeywell 7300 User manual Thermostat 20
9 Honeywell 69-1490 User manual Thermostat 10
10 Honeywell 8000 User manual Thermostat 90
11 Honeywell 8160 User manual Thermostat 9
12 Honeywell 9820i User manual Thermostat 8
13 Honeywell 8162 User manual Thermostat 3
14 Honeywell 7351F User manual Thermostat 30
15 Honeywell AC-220-7 User manual Thermostat 3
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2