Honeywell CM900 user manual

User manual for the device Honeywell CM900

Device: Honeywell CM900
Other variants:: <strong>CM927</strong>
Category: Thermostat
Manufacturer: Honeywell
Size: 0.65 MB
Added : 3/10/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell CM900. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell CM900.

For your convenience

If looking through the Honeywell CM900 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell CM900 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell CM900 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell CM900 User manual - Online PDF

Notably, the instructions presented herein can also be readily applied to other models like CM927. Whether you're a first-time user or an experienced enthusiast, this manual aims to ensure a seamless and efficient experience across various device variations.

Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell CM900 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell CM900. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CM900 Wireless
Installation Guide
CM927 / CM921 Wireless Programmable
Room Thermostat & BDR91 Relay Box
Description Table of Contents
The Honeywell CM900 Wireless (CM927 or Section Page
CM921) is a modern wireless programmable
1) Installation Information ................................. 2
room thermostat based on Honeywell’s proven
programming philosophy. To further improve the
2) Installing the CM900 Wireless System ......... 3
ease of use, this product includes an extra large
2.1 Insta

Summary of the content on the page No. 2

1) Installation Information As these products communicate using RF technology special care must be taken during installation. The location of the RF components as well as the building structure may influence performance of the RF system. To assure system reliability, please review and apply the information given below. Within a typical residential building the two products should communicate reliably within a 30m range. It is important to take into consideration that walls and ceilings will r

Summary of the content on the page No. 3

2) Installing the CM900 Wireless System Please follow the illustrations and information below in sequence to install the Relay Box and room thermostat correctly. For applications other than gas boilers, enabling special features and to see what other system options are available refer to section 4) Installer Mode. 2.1 Installing the Relay Box = M3.5 1 2 3 a. o = N 6 2 The Relay Box is a RF device. For the best performance install in an open space. Leave at least 30cm distance 1 from any met

Summary of the content on the page No. 4

2.2 Installing the Room Thermostat 2.2.1 Power Up 1. Remove the battery cover and insert the batteries supplied with the room thermostat (2 x AA LR6 Alkaline Batteries). 2. On the initial power up the available user interface languages will be displayed (only on certain models). Use the or buttons to cycle through the options until the desired language is displayed. Press the green button to confirm the selection. 3. Set the slider switch to the DATE mode. 4. Use the or buttons to set

Summary of the content on the page No. 5

1.2m 2.2.3 Locating the Room Thermostat While still in the Test Mode, as described in section 2.2.2, the room thermostat should be located taking the following into consideration and reviewing the illustrations below: 1. Find a suitable location where the signal transmission is reliable. Reliable transmission is indicated when the Relay Box is flashing the green LED every 6 seconds. NOTE: The Relay Box relay will be off. 2. Install the room thermostat EITHER on the wall using the wall bracket

Summary of the content on the page No. 6

3) Basic Operation of the System 3.1 Automatic Operation BDR91 Relay Box The Relay Box receives the heat demand (0- 100%) signal from the room thermostat. The room thermostat will display the symbol on the LCD display whenever more heat is required. Push button and Depending on the demand the Relay Box will relay status LED’s switch the heating device on to match the current requirements of the system. The green LED indicates the status of the relay output: • Gr een LED on = r elay on •

Summary of the content on the page No. 7

4.1 Entering Installer Mode 1 2 DA Y COPY DA Y DATE OFF PROG AUTO MAN OFF C M 9 2 7 1..6 The unit will display the first parameter of installer Move the slider switch to the OFF mode. parameter group category 1 (from Parameter n.1 Press and hold the button and the two & to n.19) as shown buttons together. 3 4 Press the or to Press the green change factory setting. button to confirm the change. The display will flash indicating that a change The display will stop has been made. fla

Summary of the content on the page No. 8

4.3 Using the Room Thermostat for Specific Applications The CM927/921 RF room thermostat is a versatile controller that can be used to control many different applications. For most typical applications, like wall-hung gas fired combination boiler control or zone valve control, no adjustments from the factory settings are required. For other applications, like controlling an oil burner, the best system performance can be achieved by modifying selected parameters of the room thermostat in the

Summary of the content on the page No. 9

4.5 Installer Parameters Table 4.5.1 Category 1 - Room Thermostat Settings Parameter Parameter Factory Default Setting Optional Setting No. Category 1 Parameters – Room Thermostat Settings Display Description Display Description AM-PM / 24hr 1:CL 24 24 hr clock display 12 12 hr – AM/PM clock display format Display format Reset Time/ Temp 2:rP 1 Time / Temp profile set 0 Time / Temperature are as programmed Program to factory default Changes to 0 when To restore the factory profile set to 1 one

Summary of the content on the page No. 10

4.5.2 Category 2 - System Settings Parameter Parameter Factory Default Setting Optional Setting No. Category 2 Parameters – System Settings (press the button to access this category) Display Description Display Description Minimum boiler 1:Ot 1 1 minute minimum 2 to 5 Selection of 2, 3, 4 or 5 minutes ON time ON time minimum ON time Cycle Rate 2:Cr 6 6 cycles per hour 3,9 or Selection of 3, 9 or 12 cph (cph) 12 Heat/Cool Change 4:HC 0 Disabled 1 Enabled Pump Exercise 5:PE 0 Pump exercise 1 Pum

Summary of the content on the page No. 11

5) Additional Installation Information 5.1 Binding / Rebinding Procedure The binding operation described below is required if: • Any of the system components (r oom ther mostat or Relay Box) ar e r eplaced. • The Relay Box has incorr ect or no binding data stor ed (e.g. when pr e-bound system pack components have been mismatched). NOTE: During the binding procedure keep approximately 1m distance between the room thermostat and the Relay Box. To bind/rebind: 1. Press and hold t

Summary of the content on the page No. 12

6) Trouble Shooting 6.1 Trouble Shooting Guide Symptom (Fault Possible Cause Remedy Message) The room thermostat This is normal operation. The Relay Box cycles Using the button change the the relay on and off for times proportional to displays the symbol but temperature setpoint by a few degrees. the demand signal (0-100%) from the room the Relay Box relay does The Relay Box should switch the relay on thermostat. The symbol only indicates that the not switch on. after a few seconds de


Alternative user manuals
# User manual Category Download
1 Honeywell 191108AJ User manual Thermostat 629
2 Honeywell 42011076-003 User manual Thermostat 204
3 Honeywell 69-0786-2 User manual Thermostat 57
4 Honeywell 69-1776EFS-01 User manual Thermostat 56
5 Honeywell 72838 User manual Thermostat 42
6 Honeywell 69-2485EFS-03 TH8320ZW1000 User manual Thermostat 48
7 Honeywell 5-2-DAY DELUXE RTH6300B User manual Thermostat 50
8 Honeywell 7300 User manual Thermostat 20
9 Honeywell 69-1490 User manual Thermostat 10
10 Honeywell 8000 User manual Thermostat 90
11 Honeywell 8160 User manual Thermostat 9
12 Honeywell 9820i User manual Thermostat 8
13 Honeywell 8162 User manual Thermostat 3
14 Honeywell 7351F User manual Thermostat 30
15 Honeywell AC-220-7 User manual Thermostat 3
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2