Honeywell T8411R user manual

User manual for the device Honeywell T8411R

Device: Honeywell T8411R
Category: Thermostat
Manufacturer: Honeywell
Size: 0.35 MB
Added : 3/14/2014
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell T8411R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell T8411R.

For your convenience

If looking through the Honeywell T8411R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell T8411R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell T8411R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell T8411R User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell T8411R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell T8411R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

T8411R Electronic
Heat Pump Thermostat
INSTALLATION INSTRUCTIONS
The T8411R Heat Pump Thermostat provides 24V
control of two-stage heating and one-stage cooling heat
CAUTION
pump system with manual changeover from heat to cool.
Electrical Shock or Equipment Damage
First stage heating and cooling cycle rates are fixed at
Hazard.
3 cph. Second stage heating cycle rate is selectable at
Can shock individuals or short equipment
3, 4, 5, 6, 9 or 12 cph. Temperature indication can be set
circui

Summary of the content on the page No. 2

T8411R ELECTRONIC HEAT PUMP THERMOSTAT YES NO NO 5 FEET [1.5 METERS] NO M11338 Fig. 1. Typical location of thermostat. The shape of the terminals permits insertion of straight or wraparound wiring connections; either method is acceptable. See Fig. 3. WALL WALL ANCHORS (2) 1 FOR STRAIGHT INSERTION TERMINAL STRIP 5/16 IN. (8 MM) SCREW FOR WRAPAROUND STRIP 7/16 IN. (11 MM) G L C MOUNTING WALLPLATE W2 SCREWS (2) R 1 WHEN USING WALL ANCHORS, DRILL 3/16 INCH E HOLES FOR DRYWALL, 7/32 INCH HOLES F

Summary of the content on the page No. 3

T8411R ELECTRONIC HEAT PUMP THERMOSTAT Refer to Fig. 5 for typical wiring hookups. A letter code is KEEP WIRING IN located near each terminal for identification. SHADED AREA 1. Loosen the terminal screws on the wallplate and connect the system wires. See Fig. 5. 2. Securely tighten each terminal screw. G 3. Push the excess wire back into the hole. L 4. Plug the hole with nonflammable insulation to pre- vent drafts from affecting the thermostat. C W2 Mounting Thermostat to Wallplate R 1. Engage

Summary of the content on the page No. 4

Auto On Auto On SYSTEM Auto On Cool Off Heat Em Ht SYSTEM FAN Cool Off Heat Em Ht FAN FAN Cool Off Heat Em Ht Em Ht Aux Ht Set Room SYSTEM Em Ht Aux Ht Em Ht Aux Ht Set Room Set Room T8411R ELECTRONIC HEAT PUMP THERMOSTAT FAN Switch DASHED LINES INDICATE TABS Fan switch settings are: ON BACK OF THERMOSTAT On: The fan runs continuously. Use for improved air circulation and air quality. Auto: Normal setting for most homes. The fan starts and stop

Summary of the content on the page No. 5

T8411R ELECTRONIC HEAT PUMP THERMOSTAT 2. Press the ▲▼ keys simultaneously for more than Set Temperature Setpoint one second to light all segments on display and to enter installer setup mode. When the keys are NOTE: Temperature setpoint range is 40° to 99°F (4° to released, a two-digit software revision code is dis- 39°C). played. The temperature setpoint and the room temperature are shown separately on the digital display. The ▼ indicator points to Set when the temperature setpoint is di

Summary of the content on the page No. 6

T8411R ELECTRONIC HEAT PUMP THERMOSTAT 5. Press the ▼ key to change the °C or °F indication. 10. Press the ▲ key to save all changes, exit installer setup mode and return to normal operation. NOTE: After exiting installer setup mode, change the setpoint to the desired room temperature. M14689 NOTE: Stage-one heat and cool cycle rates are fixed at 3 cph. Only stage-two heat cycle rates are CHECKOUT selectable. 6. Press the ▲ key to display the heat cycle rate of 3, Heating 4, 5, 6, 9 or 12.


Alternative user manuals
# User manual Category Download
1 Honeywell 191108AJ User manual Thermostat 629
2 Honeywell 42011076-003 User manual Thermostat 204
3 Honeywell 69-0786-2 User manual Thermostat 57
4 Honeywell 69-1776EFS-01 User manual Thermostat 56
5 Honeywell 72838 User manual Thermostat 42
6 Honeywell 69-2485EFS-03 TH8320ZW1000 User manual Thermostat 48
7 Honeywell 5-2-DAY DELUXE RTH6300B User manual Thermostat 50
8 Honeywell 7300 User manual Thermostat 20
9 Honeywell 69-1490 User manual Thermostat 10
10 Honeywell 8000 User manual Thermostat 90
11 Honeywell 8160 User manual Thermostat 9
12 Honeywell 9820i User manual Thermostat 8
13 Honeywell 8162 User manual Thermostat 3
14 Honeywell 7351F User manual Thermostat 30
15 Honeywell AC-220-7 User manual Thermostat 3
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2