Honeywell PRESTIGE THX9421 user manual

User manual for the device Honeywell PRESTIGE THX9421

Device: Honeywell PRESTIGE THX9421
Category: Thermostat
Manufacturer: Honeywell
Size: 3.78 MB
Added : 6/7/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell PRESTIGE THX9421. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell PRESTIGE THX9421.

For your convenience

If looking through the Honeywell PRESTIGE THX9421 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell PRESTIGE THX9421 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell PRESTIGE THX9421 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell PRESTIGE THX9421 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell PRESTIGE THX9421 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell PRESTIGE THX9421. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

System
Installation
Guide
®
THX9321/9421 Prestige IAQ and RF EIM
With wireless accessories
Control for up to 4 Heat/2 Cool heat pump systems or up to 3 Heat/2 Cool
conventional systems for residential and commercial applications.
Installation guide for:
• Pr estige THX9321/9421 thermostat • Wir eless Outdoor Sensor
• Equipment Interface Module (EIM) • Wir eless Indoor Sensor

• Portable Comfort Contr ol
• RedLINK Inter net Gateway
Quick start guide
1
Install thermostat .

Summary of the content on the page No. 2

System Installation Guide Your Honeywell advantage RedLINK™ Compatible Incr ease your content and pr ofit per job by including RedLINK™ accessories that meet your customers comfort and convenience needs. RedLINK accessories include the Wir eless Outdoor Sensor , Portable Comfort Contr ol (PCC), Equipment Interface Module (EIM), RedLINK Inter net Gateway , Wir eless Indoor Sensor , T rueSTEAM™ humidifier with Wir eless Adapter , T rueZONE™ zoning pan

Summary of the content on the page No. 3

R C Y Y2 G L ® THX9321/9421 Prestige IAQ and RF EIM 1 Install thermostat MCR29241 MCR32386 MCR32387 • THX9421: Mount the thermostat and wir e to C and R terminals of the Equipment Interface Module (EIM), or to a separate 24 volt transformer (not pr ovided). • THX9321: Install and wir e as above if using EIM. If not, see pages 13-15. When used with the EIM, the relays in the thermostat do not function. See pages 10-17 for detailed wiring guideline

Summary of the content on the page No. 4

System Installation Guide 3 Power optional accessories [If no wireless accessories are used, skip to Section 4.] Outdoor air sensor Indoor air sensor Portable Comfort Control MCR32937 MCR32938 MCR32939 Install 2 fresh AA lithium batteries Install 2 fresh AAA alkaline batteries Install 3 fresh AA alkaline batteries ™ RedLINK Internet Gateway The Honeywell RedLINK Inter net Gateway gives your customers r emote access to home climate-contr ol systems fr om any location with Inter

Summary of the content on the page No. 5

S2 S2 S1 S1 CONNECTED CONNECT ® THX9321/9421 Prestige IAQ and RF EIM 4 Link thermostat to the wireless network (if used with an EIM or T rueZ ONE Wireless A dap t er) ™ Next, link all components and RedLINK accessories to the wir eless network. Initial powerup configuration When the thermostat is first activated, it will lead you thr ough the steps necessary to define and set up your system. The steps will change depending on the type of system

Summary of the content on the page No. 6

MCR28847A System Installation Guide 5 Link optional accessories to wireless network While the Add Device scr een is displayed on the thermostat, press and release the CONNECT button on each wir eless device, as described below . Accessories need to be at least 2 feet away fr om the thermostat or EIM during the linking pr ocess. Press DONE after all devices have been linked Wireless outdoor sensor Wireless indoor sensor MCR32934 MCR32935 Press and release CONN

Summary of the content on the page No. 7

M28849A ® THX9321/9421 Prestige IAQ and RF EIM 6 Install optional sensors [If no sensors are used, skip to Section 7.] To install outdoor air sensor 1 Mount the sensor on a vertical exterior wall, at least 6 inches below any overhang. Choose a location pr otected fr om dir ect sunlight. 2 Place sensor secur ely in bracket, facing away fr om wall. M28491 To install indoor air sensor 1 Remove the wallplate and mount it 4 to 6 feet above the floor on an

Summary of the content on the page No. 8

System Installation Guide 7 Setup Installer options (ISU) T o configur e the thermostat, pr ess MENU > INSTALLER OPTIONS , then enter date code when pr ompted (printed on back of thermostat). Or pr ess MENU > EQUIPMENT STATUS to find the date code. A brief summary of installer options follows. Y ou can download a complete list of all options at http://customer .honeywell.com. Pr ess CREATE SETUP to set all system settings one by one. Pr ess VIEW/EDIT to selec

Summary of the content on the page No. 9

® THX9321/9421 Prestige IAQ and RF EIM 7 Installer options (ISU) Thermostat functions marked in gray below require an EIM (see page 3). ISU Function ISU Function 5080 Return Air Sensor Type B 9120 System Modes Allowing Dehumidification B 5090 Terminals Wired to Discharge Air Sensor B 9130 Dehumidifier Fan Control B 5100 Discharge Air Sensor Type B 9140 Dehumidifier Lockout B 5110 A-Coil Low Temperature Cutoff B 9180 Dehumidification Away Mode B 6000 Select the Dry Contacts in the System B 9190

Summary of the content on the page No. 10

System Installation Guide EIM wiring guide — conventional systems T ypical wiring of a conventional system with up to 3-stage heat and 2-stage cool with one transformer . FURNACE TRANSFORMER TO THERMOSTAT R EIM 24 120 C VAC VAC HEAT STAGE 1 CONV W POWER HEAT STAGE 2 W2 HEAT W3 COOL HEAT STAGE 3 STATUS FAN LEDS U1 G U2 FAN U3 A 4 COMPRESSOR Y STAGE 1 Y2 COMPRESSOR STAGE 2 1 JUMPERS 3 CONNECT OPTIONAL SENSORS TO S1 AND S2 TERMINALS SENSORS (MAX. 2 SENSORS) 2 MCR32945 1 See guides o

Summary of the content on the page No. 11

® THX9321/9421 Prestige IAQ and RF EIM EIM wiring guide — heat pump systems T ypical wiring of a heat pump system with up to four -stage heat and two-stage cool with one transformer . TO THERMOSTAT EIM O/B CHANGEOVER VALVE HEAT PUMP BACKUP HEAT POWER O/B STAGE 1 AUX1 HEAT AUX1 AUX2 BACKUP HEAT COOL AUX2 STAGE 2 STATUS FAN LEDS COMPRESSOR U1 Y STAGE 1 U2 U3 L/A Y2 COMPRESSOR STAGE 2 3 G FAN RELAY L/A COMPRESSOR MONITOR OR 3 ZONE PANEL 1 JUMPERS AIR HANDLER TRANSFORMER R 24 12

Summary of the content on the page No. 12

System Installation Guide EIM wiring guide — geothermal radiant heat T ypical wiring for geothermal radiant heat, geothermal for ced-air , and backup heat with one transformer . TO THERMOSTAT EIM O/B CHANGEOVER VALVE HEAT PUMP BACKUP HEAT POWER O/B STAGE 1 AUX1 HEAT AUX1 AUX2 BACKUP HEAT COOL AUX2 STAGE 2 STATUS FAN LEDS COMPRESSOR U1 Y STAGE 1 U2 U3 L/A COMPRESSOR Y2 STAGE 2 3 G FAN RELAY L COMPRESSOR MONITOR OR ZONE PANEL 3 GEOTHERMAL RADIANT HEAT STAGE 1 1 AIR HANDLER OPTIONAL

Summary of the content on the page No. 13

Thermostat Thermostat Thermostat Thermostat ® THX9321/9421 Prestige IAQ and RF EIM Thermostat wiring guides — Prestige THX9321 T ypical wiring of a 3-heat / 2-cool heat T ypical wiring of a 2-heat / 2-cool con - pump system with one transformer ventional system with one transformer Transformer Transformer 120 24 120 24 C C VAC VAC VAC VAC R R O/B CHANGEOVER VALVE C W HEAT STAGE 1 C AUX/E W2 BACKUP HEAT Rc HEAT STAGE 2 Rc Y COMPRESSOR STAGE 1 Y COMPRESSOR STAGE 1 R R 5 Y2 C

Summary of the content on the page No. 14

Thermostat Thermostat System Installation Guide Prestige THX9321 or EIM: Using universal relays to control heating or cooling Powering universal r elay with system Powering universal r elay with separate transformer (THX9321 shown) heating transformer (THX9321 shown) Transformer Transformer 120 24 120 24 C C VAC VAC VAC VAC R R C C HEAT STAGE 3 or COOL STAGE 3 or Rc Rc COOL STAGE 4 3 R R 2 2 U1 U1 1 1 HEAT STAGE 3 U1 U1 R U2 U2 3 Transformer 120 24 C 1 1 VAC VAC U2 U2 MCR32953 MC

Summary of the content on the page No. 15

® THX9321/9421 Prestige IAQ and RF EIM Wiring guide — IAQ equipment (EIM or thermostat) "U" terminals can be used for humidification, dehumidification or ventilation. With power supply Without power supply Typical hookup of powered humidifier. Typical hookup of non-powered humidifier. U3 U3 U3 U3 U2 U2 U2 U2 NON-POWERED U1 U1 HUMIDIFIER POWERED 24 120 FIELD INSTALLED VAC VAC HUMIDIFIER U1 U1 JUMPER BETWEEN R AND U1 RH RH RC RC R 24 120 R 24 120 24 VAC VAC 24 VAC VAC VAC VAC C C M

Summary of the content on the page No. 16

System Installation Guide Economizer Module wiring guides T ypical wiring of a W7220 Economizer Module for a heat pump system, using a Pr estige THX9321 thermostat or Equipment Interface Module. Rooftop Unit O/BN Y1 Y2 AUX AUX 2G W7220 Economizer Module (See wiring guidelines provided with the product) SD-O/B OCC E-GND AUX Y2I Y2O Y1I Y1O C R O/B L/A YY2 AUX AUX 2G 1 2 Transformer R 120 24 Thermostat/EIM C VAC VAC MCR32959 T ypical wiring of a W7220 Economizer Module f

Summary of the content on the page No. 17

® THX9321/9421 Prestige IAQ and RF EIM Economizer Module wiring guides T ypical wiring of a W7213/W7214 Economizer Module for a heat pump system, using a Pr estige THX9321 thermostat or Equipment Interface Module. Rooftop Unit O/BN Y1 Y2 AUX AUX 2G W7213/W7214 Economizer Module (See wiring guidelines provided with the product) O or B N 3 4 1 2 & 5 TR1 TR O/BL/A YY2 AUX AUX 2G 1 2 Transformer R 120 24 Thermostat/EIM VAC VAC C MCR32956 T ypical wiring of a W7212 Economizer

Summary of the content on the page No. 18

System Installation Guide Economizer and TOD operation (ISU 2220) Commercial use only The Economizer can gr eatly r educe energy costs if configur ed pr operly . In some climates the cooling system may run hundr eds of hours, when it may not be r equir ed to maintain indoor comfort. In some conditions, ventilation with outdoor air can achieve the same level of comfort at lower cost. T ables below explain how the Economizer featur e maintain

Summary of the content on the page No. 19

® THX9321/9421 Prestige IAQ and RF EIM Heat pump with outdoor temperature lockouts Outdoor temperatur e lockouts ar e optional. See Installer Setup options (ISU 3120). Backup heat allowed to run with heat pump (see table below) Heat pump only Backup heat lockout Heat pump with backup heat as needed * Compressor lockout Backup heat only * No backup heat unless indoor temperature drops to selected Backup Heat Differential setting, or Backup Heat Upstage Timer expires. Heat pump stays O

Summary of the content on the page No. 20

System Installation Guide Basic and Advanced Temperature Control Options (ISU 3010) Basic Options: The Installer Setup displays basic temperatur e contr ol options which include Backup Heat Dif fer ential, Backup Heat Upstage Timer and Outdoor T emperatur e Lockouts. Note: Outdoor T emperatur e Lockouts only apply to Heat Pump applications. Advanced Options: The Installer Setup displays both Basic and Advanced Options. Advanced temperatur e contr ol


Alternative user manuals
# User manual Category Download
1 Honeywell 191108AJ User manual Thermostat 629
2 Honeywell 42011076-003 User manual Thermostat 204
3 Honeywell 69-0786-2 User manual Thermostat 57
4 Honeywell 69-1776EFS-01 User manual Thermostat 56
5 Honeywell 72838 User manual Thermostat 42
6 Honeywell 69-2485EFS-03 TH8320ZW1000 User manual Thermostat 48
7 Honeywell 5-2-DAY DELUXE RTH6300B User manual Thermostat 50
8 Honeywell 7300 User manual Thermostat 20
9 Honeywell 69-1490 User manual Thermostat 10
10 Honeywell 8000 User manual Thermostat 90
11 Honeywell 8160 User manual Thermostat 9
12 Honeywell 9820i User manual Thermostat 8
13 Honeywell 8162 User manual Thermostat 3
14 Honeywell 7351F User manual Thermostat 30
15 Honeywell AC-220-7 User manual Thermostat 3
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2