Honeywell R7500C user manual

User manual for the device Honeywell R7500C

Device: Honeywell R7500C
Category: Thermostat
Manufacturer: Honeywell
Size: 0.16 MB
Added : 11/14/2014
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell R7500C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell R7500C.

For your convenience

If looking through the Honeywell R7500C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell R7500C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell R7500C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell R7500C User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell R7500C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell R7500C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

R7500C Wide Range Proportional
Temperature Controller
INSTALLATION INSTRUCTIONS

They are fastened to the mounting surface through the two
diagonally opposed mounting holes in the back of the case.
See Fig. 1.
For access to the mounting holes, remove the cover from the
case by loosening the cover mounting screw.
The mounting holes are now visible through the circuit board
notches in the upper right and lower left-hand corners.
Determine placement of the mounting holes in the surface
an

Summary of the content on the page No. 2

R7500C WIDE RANGE PROPORTIONAL TEMPERATURE CONTROLLER Table 1. Wire Resistance, Ohms per 1,000 Feet (304m). WIRING Wire Dia. Ohms/1000 ft All wiring must agree with local electrical codes and Wire Gage Size (mm) (304 m) of Wire ordinances. 18 1.00 6.5 Since the Controller circuits are rated NEC Class 2, some 16 1.25 4.0 local codes allow open (no conduit) wiring. 14 1.60 2.6 Number 18 gage 1.0 mm insulated wire or two- or three­ 12 2.00 1.6 conductor thermostat cable is accepta

Summary of the content on the page No. 3

R7500C WIDE RANGE PROPORTIONAL TEMPERATURE CONTROLLER 11-12 Vdc + POWER – SUPPLY MODULTROL IV MOTOR BALCO 1 MAIN SENSOR BLACK ORANGE L1 T2 C 8.2K L2 T1 ORANGE YELLOW R X-FORMER R7500 VIOLET BROWN M7186A1004 2 M7185G1000 BALCO COMPENSATION SENSOR 1 C AND T2 ARE INTERNALLY CONNECTED. AN 8.2K OHM RESISTOR IS PROVIDED INTERNALLY TO CORRECTLY LOAD THE R7500 OUTPUT. 2 OPTIONAL COMPENSATION SENSOR. SUBSTITUTE WITH 500 OHM RESISTOR WHEN COMPENSATION IS NOT USED. C7830

Summary of the content on the page No. 4

R7500C WIDE RANGE PROPORTIONAL TEMPERATURE CONTROLLER COMPENSATION RATIO ADJUSTMENT CHECKOUT AND TESTING Compensation ratio is the number of degrees temperature CHECKOUT change required at the compensation sensor to change the primary sensor control point one degree F. The only checkout ordinarily required is to slowly rotate the When a compensation sensor (T2) is used, the compensation Setpoint Adjustment through the total proportional band of the ratio adjustment provides a means for

Summary of the content on the page No. 5

R7500C WIDE RANGE PROPORTIONAL TEMPERATURE CONTROLLER NOTE: 1. To ensure correct voltage readings in the following tests, a 500-ohm resistor should be substituted for the compensation sensor (if its temperature is not near 75F [24C]) and “comp. ratio” should be set at 20. 2. If the controller output is not connected, wire a 390 ohm “load” resistor from orange to yellow wires. R7500 Adjust setpoint knob to correspond to the ambient temperature at the main sensor. Set the proportion

Summary of the content on the page No. 6

Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited-Honeywell Limitée Honeywell Plaza 740 Ellesmere Road P.O. Box 524 Scarborough, Ontario QUALITY IS KEY Minneapolis, MN 55408-0524 M1P 2V9 95-7205 Rev. 10-95 Printed in U.S.A.


Alternative user manuals
# User manual Category Download
1 Honeywell 191108AJ User manual Thermostat 629
2 Honeywell 42011076-003 User manual Thermostat 204
3 Honeywell 69-0786-2 User manual Thermostat 57
4 Honeywell 69-1776EFS-01 User manual Thermostat 56
5 Honeywell 72838 User manual Thermostat 42
6 Honeywell 69-2485EFS-03 TH8320ZW1000 User manual Thermostat 48
7 Honeywell 5-2-DAY DELUXE RTH6300B User manual Thermostat 50
8 Honeywell 7300 User manual Thermostat 20
9 Honeywell 69-1490 User manual Thermostat 10
10 Honeywell 8000 User manual Thermostat 90
11 Honeywell 8160 User manual Thermostat 9
12 Honeywell 9820i User manual Thermostat 8
13 Honeywell 8162 User manual Thermostat 3
14 Honeywell 7351F User manual Thermostat 30
15 Honeywell AC-220-7 User manual Thermostat 3
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2