ritetemp 8050C user manual

User manual for the device ritetemp 8050C

Device: ritetemp 8050C
Category: Thermostat
Manufacturer: ritetemp
Size: 1.8 MB
Added : 5/27/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ritetemp 8050C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ritetemp 8050C.

For your convenience

If looking through the ritetemp 8050C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ritetemp 8050C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ritetemp 8050C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ritetemp 8050C User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ritetemp 8050C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ritetemp 8050C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Install guide 8050C
ENGLISH
Customer Support: 888-515-2585 or
Visit our website www.ritetemp-thermostats.com
1-405-061
Made in China
AUTO ON
HEAT COOL
AUTO ON
HEAT COOL
OFF FAN
OFF FAN

Summary of the content on the page No. 2

Install guide 8050C To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. Caution This can be done at the circuit breaker, or at the appliance. You will need #1 Phillips screwdriver (small) and Tools Drill with 3/16-in. (4.8mm) bit for this installation. 1 Location . On replacement installations, mount the new thermostat in place of the old one if possible. . On new Installations, follow the g

Summary of the content on the page No. 3

2 Label Wires from Old Unit . Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. . Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened. . Note the letters printed near the terminals. . Carefully attach labels (enclosed) to each wire. Label the wires one at a time. You must have all the wires labeled before you proceed. Read instructions carefully

Summary of the content on the page No. 4

A G Y W RH B O RC W2 C 5 Gas-Electric Selection I REFER to the back of the Control Unit: If you have Electric Heat or a Heat Pump you must place the Gas/Electric jumper in the ELECT position (thermostat controls the Fan). If you have Gas Heat the Gas/Electric Jumper should be in the GAS position (furnace controls the Fan). 6 Heat Pump Switch If you have a HEAT PUMP: . Change the NORMAL/PUMP o o C - F switch on the back of the unit jumper Differential to PUMP. ju

Summary of the content on the page No. 5

PG 7 9 Wire Connections Make sure your wires are labeled. This is necessary to determine which step-by-step wiring diagram you should use. This may require you to find the 'other end' connection for each wire on your heating or air conditioning equipment and read the label there. If you have a Zoned Heating/Cooling system with multiple thermostats, please refer to our website at www.ritetemp-thermostats.com for installation notes or call 1-888-515-2585. Before you Connect Wires Please

Summary of the content on the page No. 6

NOTE: Wires marked with dotted line are optional. Go To Page 11 Go To Page 12 Go To Page 13 Go To Page 14 Go To Page 15 Go To Page 17 Go To Page 16 If you do not find the wiring information for your system try our website: www.ritetemp-thermostats.com for more information or call our PG 9 customer service at 888-515-2585.  9 Wire Connections cont When you have finished connecting the wires attach control unit to wall unit. Hook the top of the body onto the base, swing the body down, and sna

Summary of the content on the page No. 7

2 WIRE Thermostat jumper NOTE: Wires marked with wire the dotted line are optional. C R W HEAT HEAT Power FURNACE STEP 1 - Connect the R (or RH) wire to the RH terminal on the thermostat. This connects to the Heater Power. STEP 2 - Connect the W wire to the W terminal on the thermostat. This connects the heater control line to the thermostat. Your heater is now connected to the thermostat. Go To Page 10 PG 11 3 WIRE Thermostat jumper NOTE: Wires marked with wire the dotted line are

Summary of the content on the page No. 8

4 WIRE NON-HEAT PUMP STEP 1 - Connect the Y wire Thermostat to the Y terminal on the thermostat. This connects to the Cooler compressor. jumper wire STEP 2 - Connect the RH or R wire to the RH G terminal on the thermostat. C RH W Y Cool Heat This connects the Heater/Cooler Power. Heat FAN Power Comp HVAC SYSTEM STEP 3 - Connect the W wire to the W terminal on the thermostat. NOTE: Wires marked with This connects to the heater control line. the dotted line are optional. STEP 4 - Conne

Summary of the content on the page No. 9

NORMAL 2 Stage  Heat System STEP 1 - Connect the G wire to jumper wire the G terminal on the thermostat. Thermostat This connects the Fan. STEP 2 - Connect the W wire to the W terminal. This connects the 1st stage heat. STEP 3 - Connect the W2 wire to the W2 G C W2 R W terminal. This connects the 2nd stage heat. Two Stage FAN Furnace STEP 4 - Connect the R wire to the RH terminal Two Stage Heat System on the Thermostat. This connects to the 24vac NOTE: Wires marked with power. the do

Summary of the content on the page No. 10

HEAT PUMP STEP 1 - Connect the G wire to with Auxiliary Heat the G terminal on the thermostat. jumper wire This connects the Fan. STEP 2 - Add a jumper wire Thermostat between W and Y. STEP 3 - Connect the Y wire to the Y terminal on the thermostat. jumper O or B wire (not both) This connects the Compressor. STEP 4 - Connect the O or B wire to the R O or B Y G C O or B terminal on the thermostat. (If you have both AUX Change Comp FAN Heat O and B wires, use the O and tape off the B).


Alternative user manuals
# User manual Category Download
1 ritetemp 401-014 User manual Thermostat 53
2 ritetemp 8030C User manual Thermostat 63
3 ritetemp 8035C User manual Thermostat 23
4 ritetemp GPMG8010 User manual Thermostat 4
5 ritetemp 6030 User manual Thermostat 64
6 ritetemp 8022 User manual Thermostat 39
7 ritetemp 8022C User manual Thermostat 0
8 ritetemp 6036 Operating instructions Thermostat 0
9 ritetemp 6022 Installation guide Thermostat 0
10 ritetemp 8082C Installation guide Thermostat 0
11 ritetemp 8035c User manual Thermostat 0
12 ritetemp 6080 Installation guide Thermostat 0
13 ritetemp 8022C Operating instructions Thermostat 0
14 Edelbrock 2116 User manual Thermostat 0
15 A&D MF-50 User manual Thermostat 8
16 A&D ML-50 User manual Thermostat 8
17 A&D MS-70 User manual Thermostat 15
18 Acu-Rite D1523 User manual Thermostat 2