Energy Tech Laboratories 8358 user manual

User manual for the device Energy Tech Laboratories 8358

Device: Energy Tech Laboratories 8358
Category: Heat Pump
Manufacturer: Energy Tech Laboratories
Size: 1.61 MB
Added : 6/19/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Energy Tech Laboratories 8358. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Energy Tech Laboratories 8358.

For your convenience

If looking through the Energy Tech Laboratories 8358 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Energy Tech Laboratories 8358 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Energy Tech Laboratories 8358 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Energy Tech Laboratories 8358 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Energy Tech Laboratories 8358 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Energy Tech Laboratories 8358. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

L
I
S
INSTALLATION & OPERATING
INSTRUCTIONS
Heat Pump
Pool & Spa
Heater
Model Series
5356, 5357, 5358,
6356, 6357, 6358,
8357 & 8358
R
C US
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance. To
do so may result in an explosion or fire.
NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced
in the installation and maintenance o

Summary of the content on the page No. 2

Water Chemistry (Corrosive water voids all warranties) For your health and the protection of your pool equipment, it is essential that your water be chemically balanced. The following levels must be used as a guide for balanced water. Recommended Level(s) Fiberglass Pools Fiberglass Spas Other Pool & Spa Types Water Temp. (Deg. F) 68 to 88 89 to 104 68 to 104 pH 7.3 to 7.4 7.3 to 7.4 7.6 to 7.8 Total Alkalinity (PPM) 120 to 150 120 to 150 80 to 120 Calcium Hardness (PPM) 200 to 300 150 to 200 20

Summary of the content on the page No. 3

CONTENTS Water Chemistry 2 Continuous Pump Operation 9 Warnings 4 Maintenance 9 Pay Attention to These Terms 4 Air Coil Cleaning 9 Introduction 5 Cabinet Care (optional) 9 Installation Considerations 5 Unplug Condensation Drain Holes 9 Electrical Connections 6 Troubleshooting 10 Water Connections 7 Service Call Verification 11 Controls 7 Power Supply 11 Controls Operating Instructions 9 Water Flow 11 To Select Pool or Spa Mode 8 Time Clock Adjustment 11 Plumbing Diagrams 12 To Increase the Desir

Summary of the content on the page No. 4

Warnings — Pay Attention to These Terms Indicates the presence of immediate hazards which will cause severe personal injury, death DANGER: or substantial property damage if ignored. Indicates the presence of hazards or unsafe practices which could cause severe personal WARNING: injury, death or substantial property damage if ignored. Indicates the presence of hazards or unsafe practices which could cause minor personal CAUTION: injury or product or property damage if ignored. Indicates special

Summary of the content on the page No. 5

Introduction Installation Considerations WARNING: Do not install the unit within 3 ft of WARNING: This pool/spa heat pump pool heater is fossil fuel burning heaters. Air intake along the an electromechanical machine that incorporates a sides of this heat pump pool heater could disturb pressurized refrigerant gas in a sealed system. the combustion process of the unit, and could ONLY trained and qualified service personnel are cause damage or personal injury. authorized to install or service this

Summary of the content on the page No. 6

60” (1.5m) MIN AIR FLOW OUT 3 FT (90cm) 12” (30cm) MIN MIN AIR AIR GAS FLOW FLOW HEATER IN IN Fig. 1: Installation Clearances • When installed in areas where freezing tempera- • In sizing power wiring, be especially aware of up- tures can be encountered, drain the water circuit sizing requirements necessary due to wiring to prevent possible freeze-up damage. See the distances. Always satisfy applicable codes and Freeze Protection Section. standards. • Electrical installation should be done by a

Summary of the content on the page No. 7

WATER IN WATER OUT Fig. 2: Water Connections Water Connections Controls CAUTION: The heat pump pool heater inlet and Your heat pump pool heater incorporates digital safety outlet connections are NOT interchangeable. They controls and indicators to ensure its safe, reliable must be connected as instructed below. operation. 1. Connect the heat pump pool heater in the return Water Pressure Switch: Prevents operation when the water line between the filter and the pool/spa. See pump is OFF. The unit

Summary of the content on the page No. 8

Defrost Sensor: Prevents unit operation if ambient air To Select Temperature in °C or °F temperature falls below a predetermined safe mini- mum (approximately 42°–48°F, based on humidity). Press the SET key until you see F _C. By pressing the The compressor will shut OFF but the fan will continue UP or DOWN key you can switch to °F or °C. Once the to run. temperature display mode has been programmed it will be displayed for approximately 5 seconds, then Delay Timer: Prevents compressor from shor

Summary of the content on the page No. 9

Continuous Pump Operation NOTE: If the pool pump and heat pump pool heater shut OFF before the water temperature is raised to It is also possible in some areas to prevent unit freeze the desired level, you must lengthen the running time damage by operating the pump continuously during of both. To do this, reset the time clock dial for the freezing weather. However, this results in significantly longer running time, or manually operate the pump higher pump operating costs. Further, if a sustained

Summary of the content on the page No. 10

• Is the pool blanket/cover being used? Troubleshooting Unblanketed pools can lose up to 10 degrees per night compared to 4 degrees or fewer when a If your unit does not operate, or simply does not heat blanket is used. Without a blanket, the total heat your pool water, Fault Codes on the front control gained during the day can be lost overnight. panel, can provide valuable clues as to what is wrong, and may even indicate precisely what the problem is. • Are rapid heat losses occurring in some o

Summary of the content on the page No. 11

Water Flow Service Call Verification • Verify that the pool filter is clean to provide good Before you make a service call, first determine if the flow. problem is: • Verify that valves are properly positioned to allow • Warranty Service adequate water flow through the unit. • Unit operation (power supply, water flow, or time Time Clock Adjustment clock adjustment) Verify that the time clock is set to permit the unit to run NOTE: The MANUFACTURER IS NOT RESPON- long enough to heat properly. SIBL

Summary of the content on the page No. 12

Plumbing Diagrams Fig. 4: For systems with pumps of less than 2 HP (under 80 gpm), no external bypass is required. Connections are 2-inch unions. Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators. 12 CHEMICAL INTRODUCTION WATER OUT (TO POOL OR SPA) CHECK VALVE FILTER WATER IN (FROM POOL OR SPA)

Summary of the content on the page No. 13

Fig. 5: For systems with pumps of 2 HP or greater (over 80 gpm), an external bypass is required. Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater. Connections are 2-inch unions. Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators. 13 CHEMICAL INTRODUCTION WATER OUT (TO POOL OR SPA) CHECK VALVE FILTER WATER IN (FROM POOL OR SPA)

Summary of the content on the page No. 14

Fig. 6: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 14

Summary of the content on the page No. 15

Fig. 7: Pool Piping for Heat Pump Pool Heaters, Multiple, Primary/Secondary 15 UNITS UNITS UNITS

Summary of the content on the page No. 16

Wiring Diagram 220/240V Single-Phase 16

Summary of the content on the page No. 17

Wiring Diagram 200/220V Three-Phase 17

Summary of the content on the page No. 18

Wiring Diagram 380/420V Three-Phase 18

Summary of the content on the page No. 19

Installing a Remote Control Device Wiring For a 2-wire control, use the TOTAL and COMMON connections on the heat pump pool heater wiring block. For a 3-wire control, use the COMMON, SPA and POOL connections on the heat pump pool heater wiring block. Heater Settings 1. Make sure the heater is disabled on the remote control device. Then, push the SET key until POL Fig. 8: Heater Wiring Block is displayed. Push the DOWN arrow key until OFF is displayed. Wait until a temperature is displayed before

Summary of the content on the page No. 20


Alternative user manuals
# User manual Category Download
1 Energy Tech Laboratories 6357 User manual Heat Pump 2
2 Energy Tech Laboratories 5357 User manual Heat Pump 0
3 Energy Tech Laboratories 6358 User manual Heat Pump 0
4 Energy Tech Laboratories 5358 User manual Heat Pump 0
5 Energy Tech Laboratories 6356 User manual Heat Pump 0
6 Energy Tech Laboratories Homes Northwest User manual Heat Pump 0
7 Energy Tech Laboratories POOL & SPA 5310 User manual Heat Pump 0
8 Energy Tech Laboratories 8357 User manual Heat Pump 0
9 Energy Tech Laboratories POOL & SPA 8320 User manual Heat Pump 0
10 Energy Tech Laboratories POOL & SPA 6310 User manual Heat Pump 0
11 Energy Tech Laboratories 5356 User manual Heat Pump 0
12 Edelbrock 15005 User manual Heat Pump 0
13 A.O. Smith AH User manual Heat Pump 2
14 ACS 882.00217.00 User manual Heat Pump 1
15 A.O. Smith AHD 290 User manual Heat Pump 3
16 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5