Rheem RUTG-66DV user manual

User manual for the device Rheem RUTG-66DV

Device: Rheem RUTG-66DV
Category: Water Heater
Manufacturer: Rheem
Size: 3.88 MB
Added : 2/16/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Rheem RUTG-66DV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Rheem RUTG-66DV.

For your convenience

If looking through the Rheem RUTG-66DV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Rheem RUTG-66DV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Rheem RUTG-66DV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Rheem RUTG-66DV User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Rheem RUTG-66DV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Rheem RUTG-66DV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

C
N
E
G
R
I
T
Use & Care Manual
With Installation Instructions for the Installer
Direct Vent Gas
Tankless Water Heater
!
Warning: This water heater is not suitable
for use in manufactured (mobile) homes!
The purpose of this manual is twofold: one, to provide the installer with
the basic directions and recommendations for the proper installation
and adjustment of the water heater; and two, to the owner–operator,
Paloma to explain the features, operation, safety precautions, maintenance and
t

Summary of the content on the page No. 2

Safety Information FOR YOUR RECORDS Safety Precautions . . . . . . 3–6 . Write the model and serial numbers here: LP Gas Models . . . . . . . . . . . 5 # Installation Instructions # Location . . . . . . . . . . . . . . . . . 7 . You can find them on a label on the appliance. Inspect Shipment . . . . . . . . . . 8 . Staple sales slip or cancelled check here . Venting . . . . . . . . . . . . . . . 9-14 Proof of the original purchase date is needed to obtain service under the warranty. Water

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION . READ ALL INSTRUCTIONS BEFORE USING . Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified service tec

Summary of the content on the page No. 4

IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING . ! DANGER! WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of a water heater’s remote control. Water temperatures above 125°F (52°C) can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. Time/Temperature Relationship in Scalds Water Temperature Time To Produce a Serious B

Summary of the content on the page No. 5

DANGER! NATURAL GAS AND LIqUEFIED PETROLEUM MODELS Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak. Notice: If a gas leak is present or suspected: ● W ater heaters uti

Summary of the content on the page No. 6

IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING . ! WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury or loss of life. FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For water heaters up to 52 gallo

Summary of the content on the page No. 7

Installing the water heater : This water heater must be installed in accordance with these instructions, local codes, utility company requirements and/or in the absence of local codes, use the latest edition of the American National Standard/ National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 North Capitol Street Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269 as N

Summary of the content on the page No. 8

C N E G R I T Installing the water heater: NOTICE: The water heater Corrosive Atmospheres should not be installed near The air in beauty shops, dry cleaning Propellants from common spray cans an air supply containing establishments, photo processing labs, or gas leaks from A/C and refrigeration halogenated hydrocarbons. and storage areas for liquid and powdered equipment are highly corrosive after bleaches or swimming pool chemicals passing through a flame . often contains such halogena

Summary of the content on the page No. 9

The water heater must be installed with a 3”/5” diameter UL approved Category III Coaxial Stainless Steel appliance coaxial vent pipe and an appropriate adapter. Venting DANGER: Failure to The installation of venting must comply Notes on pre-existing vent: install the appliance vent with national codes, local codes and the adapter and properly vent YES! NO! vent manufacturer’s instructions . the water heater to the outdoors as outlined in the The water heater must be vented to the Ven

Summary of the content on the page No. 10

Installing the water heater: Venting Through Closed Spaces If the coaxial vent piping passes through a closed space, a minimum clearance of 1” (2 .5 cm) when installed horizontally or 6” (15 cm) when 7/8" per foot Wall Plates downward slope installed vertically should be maintained between the coaxial vent pipe and combustibles and noncombustibles . Be sure to follow local codes 94° Elbow and vent manufacturer’s installation instructions . Fire 2’ Stop Vent Pipe (61 cm) For maint

Summary of the content on the page No. 11

D E B V V L air Supply inlet area Where terminal iS nOt permitted V Vent terminal X Horizontal Vent Terminal Location The following information should be used for determining the proper location of the vent terminal for direct vent tankless water heaters . 1 2 Canadian installations uS installations A= Clearance above grade, veranda, 12 inches (30 cm) above anticipated 12 inches (30 cm) above anticipated porch, deck or balcony . snow level . snow level . B= Clearance to window or doo

Summary of the content on the page No. 12

Installing the water heater: Additional Considerations Indoor Water Heater Do NOT install vent terminal under any patio or deck . T o help prevent moisture from freezing on walls and under Caulk eaves, do not locate vent terminal on the side of a building with Rising moisture will prevailing winter winds . collect under eaves . To help prevent water lines from freezing, do not locate vent If soffit vent is too close, terminal on the side of a building with prevailing winter winds . bl

Summary of the content on the page No. 13

Caulk for weather seal Installing the water heater: Horizontal Vent Installation continued. Use 4 hollow wall anchors, at least Install the appliance adapter onto the 1/8 inch (0 .32 cm) in diameter and of appliance and use (4) four screws to appropriate length for the thickness of secure the appliance adapter to the the sheathing, if sheathing is particle appliance . Now attach other required board or other composite material . vent and air intake material between Inner W all Outer Wall Pl

Summary of the content on the page No. 14

Support Installing the water heater: Vertical Vent Termination Location The location of the vent terminal depends on the following Only Rheem approved minimum clearances and considerations (see diagram at left): termination and parts 2 Minimum twelve (12) inches (30 cm) above roof . should be used during installation. Minimum twelve (12) inches (30 cm) above anticipated snow level . Vent Pipe Through Roof Maximum twenty-four (24) inches (60 cm) above roof level without additional supp

Summary of the content on the page No. 15

Mounting the Water Heater Make sure the location of the appliance allows lower bracket to the wall (Left and Right) . CAUTION: for easy access and operation . Repeat to affix the top bracket . Reinforcement of the wall is Wall studs should be utilized when mounting The brackets can be adjusted to change the required in case the wall is the water heater to the wall . Alternately, a distance between the back of the appliance not strong enough to hold the appliance. suitable piece of wood ma

Summary of the content on the page No. 16

Installing the water heater: Water Supply Connections, continued Notice: If the water flow resistance of a Be sure to connect the water inlet and the CAUTION: This water shower head is too high, the burner in the hot water outlet as shown on the water heater must only be used with water heater will fail to ignite . Keep the heater . If reversed, the water heater will the following water supply shower head clean from debris that could system conditions: not function . cause additional pres

Summary of the content on the page No. 17

Relief Valve A new pressure relief valve, complying ● The end of the discharge line should not with the Standard for Relief Valves and Drain Valve be threaded or concealed and should be shown on Automatic Gas Shut-Off Devices for Hot protected from freezing . No valve of any right without Water Supply Systems, ANSI Z21.22/ type, restriction or reducer coupling should tubing . CSA 4.4, must be installed at the hot water be installed in the discharge line . outlet connection of the wa

Summary of the content on the page No. 18

Installing the Main Remote Control: WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Gas Supply The supplied Manual Gas Appliance Shutoff A sediment trap should be installed at the Valve must be installed at the gas connection of bottom of the gas line . the water heater at the time of installation (see Do not use excessive force (over 31 . 5

Summary of the content on the page No. 19

PRIORITY °F POWER ON/OFF WARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part 1. Remote Control Installation One (1) remote control is provided with the may be subjected to oil and/or steam NOTICE: The provided water heater . Additional remote controls may from cooking . remote control will allow

Summary of the content on the page No. 20

Installing the Main Remote Control: WARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part 1. Remote Control Installation NOTICE: Extension cable Connecting the MAIN (UMC-117 ) remote Connecting the remote control to the water can be any Type-T 18 AWG control to the water heater: heater: wire similar


Alternative user manuals
# User manual Category Download
1 Rheem 000 BTU User manual Water Heater 107
2 Rheem 100 User manual Water Heater 105
3 Rheem 000 BTU max User manual Water Heater 18
4 Rheem 120 User manual Water Heater 83
5 Rheem 000 - 180 User manual Water Heater 39
6 Rheem 11 User manual Water Heater 6
7 Rheem 175 User manual Water Heater 1
8 Rheem 110 User manual Water Heater 7
9 Rheem 130 User manual Water Heater 6
10 Rheem 19 User manual Water Heater 9
11 Rheem 208 User manual Water Heater 0
12 Rheem 136-1826 User manual Water Heater 8
13 Rheem 115 User manual Water Heater 2
14 Rheem 199 User manual Water Heater 6
15 Rheem 240 User manual Water Heater 4
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6