AURORA PRODUCTS 441 user manual

User manual for the device AURORA PRODUCTS 441

Device: AURORA PRODUCTS 441
Category: Water Pump
Manufacturer: AURORA PRODUCTS
Size: 1.19 MB
Added : 8/7/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for AURORA PRODUCTS 441. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with AURORA PRODUCTS 441.

For your convenience

If looking through the AURORA PRODUCTS 441 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual AURORA PRODUCTS 441 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual AURORA PRODUCTS 441 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
AURORA PRODUCTS 441 User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual AURORA PRODUCTS 441 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to AURORA PRODUCTS 441. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION,
MODEL 441
OPERATION AND
MAINTENANCE HORIZONTAL SPLIT CASE
&
INSTRUCTIONS
FOR

MODEL 491
SPLIT CASE FIRE PUMP










Summary of the content on the page No. 2

TABLE OF CONTENTS PAGE i TOPIC PAGE PUMP IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STORAGE OF PUMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CAUTION NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

Summary of the content on the page No. 4

PUMP IDENTIFICATION PAGE 1 PUMP IDENTIFICATION Congratulations! You are the owner of one of the finest pumps commercially available. If you give it the proper care as outlined and recommended by this manual, it will provide you with reliable service and long life. 441 & 491 SPLIT CASE PUMPS Your Aurora Model 441 & 491 is a Split Case Pump, meaning the casing is split along the horizontal centerline. This new compact design, with its shorter bearing span, has l

Summary of the content on the page No. 5

PAGE 2 STORAGE OF PUMPS AND CAUTION NOTES THESE INSTRUCTIONS APPLY TO THE PUMP ONLY. THEY ARE INTENDED TO BE GENERAL AND NOT SPECIFIC. IF YOUR OPERATING CONDITIONS EVER CHANGE, ALWAYS REFER TO THE FACTORY FOR REAPPLICATION. ALWAYS REFER TO THE MANUALS PROVIDED BY MANUFACTURERS OF THE OTHER EQUIPMENT FOR THEIR SEPARATE INSTRUCTIONS. CAUTION IMPORTANT SAFETY NOTICE THE INSTALLATION, USE AND OPERATION OF THIS TYPE OF EQUIPMENT IS AFFECTED BY VARIOUS FEDERAL, STATE AND LOCAL L

Summary of the content on the page No. 6

INTRODUCTION AND INSTALLATION PAGE 3 INTRODUCTION This manual contains information which is the result of carefully conducted engineering and research efforts. It is designed to supply adequate instructions for the safe and efficient installation, operation maintenance of your pump. Failure or neglect to properly install, operate or maintain your pump may result in personal injury, property damage or unnecessary damage to the pump. Variations exist in both the equipment us

Summary of the content on the page No. 7

PAGE 4 INSTALLATION (continued) 3. MINIMUM SUBMERGENCE OF SICTION PIPE AND PIT DESIGN For installations where the pump draws fluid from a sump, the hydraulic characteristics of the pump, the suction inlet submergence and NPSH must be considered. Generally, it is required that an evenly distributed flow of non-aerated water be supplied to the suction bell. Improper pit design or insufficient suction pipe submergence can result in intake vortexing which reduces the pump’s perf

Summary of the content on the page No. 8

INSTALLATION (continued) PAGE 5 7. GROUTING When the alignment is correct, the unit should be grouted using high grade non-shrinking grout. The entire base should be filled with grout. Be sure to fill all gaps and voids. Allow the grout to fully cure before firmly tightening the foundation bolts. Then recheck the alignment before connecting the piping. 8. PIPING CAUTION: ALL PIPING CONNECTIONS MUST BE MADE WITH THE PIPING IN A FREE SUPPORTED STATE, AND WITHOUT THE NEE

Summary of the content on the page No. 9

PAGE 6 INSTALLATION (continued) BEARING HOUSING OIL LEVEL CHART 4-441-11A/C 5-441-18A 5-441-11A PUMP MODEL 3-441-9A/C 4-441-14C 6-441-14A/C 6-441-19A 2-441-8A (PUMP SIZE) 4-441-8A 5-441-14A 6-441-18C 8-441-18A 6-441-12A 8-441-14A 10-441-20 Centerline of shaft to oil level 3/4" 7/8" 1-3/16" 1-1/2" 1-13/16" NOTE: For Fire Pumps, the Model designation changes from “441” to “491.” Adjust the oil level, if necessary, by loosening the setscrews on the side of the dust cap, raising th

Summary of the content on the page No. 10

INSTALLATION (continued) PAGE 7 FIGURE 3 COUPLING ALIGNMENT 11. FINAL COUPLING ALIGNMENT (continued) C Check the angular alignment with a micrometer or caliper. Measure from the outside of one flange to the outside of the other at intervals around the periphery of the coupling. Determine the maximum and minimum dimensions. DO NOT ROTATE THE COUPLING. The difference between the maximum and minimum dimensions should not exceed the figure shown under “Angular” in the

Summary of the content on the page No. 11

PAGE 8 INSTALLATION continued) 14. MECHANICAL SEALS CAUTION: DRY OPERATION OF THE PUMP MAY CAUSE DAMAGE TO THE MECHANICAL SEAL AND IMPELLER. Model 441 pumps can be supplied with optional single face mechanical shaft seals. Mechanical seals are installed and adjusted in the factory and require no further adjustments in the field. For further information, refer to the seal manufacturer’s instructions. FIGURE 4 TYPICAL MECHANICAL SEAL

Summary of the content on the page No. 12

OPERATION PAGE 9 Because variations exist in both the equipment used with these pumps and in the particular installation of the pump and driver, specific operating instructions are not within the scope of this manual. However, there are general rules and practices that apply to all pump installations and operation. CAUTION: BEFORE STARTING OR OPERATING THE PUMP, READ THIS ENTIRE MANUAL, ESPECIALLY THE FOLLOWING INSTRUCTIONS: A. BEFORE STARTING THE PUMP, INSTALL CLOSED GU

Summary of the content on the page No. 13

PAGE 10 OPERATION (continued) 3. STARTING THE PUMP A. After the pump is primed, and with the discharge valve closed and the suction valve open, start the driver according to the driver manufacturer’s instructions. B. Open the discharge valve slowly to prevent water hammer. C. After the pump has been started, check bearing temperatures, packing box lubrication and operation and pump noise level for a period of several hours. CAUTION: BEGIN THESE CHECKS IMMEDIATELY UPON STA

Summary of the content on the page No. 14

MAINTENANCE PAGE 11 1. MAINTENANCE HISTORY SYMBOL DATE MAINTENANCE PERFORMED PARTS USED NUMBER(S)

Summary of the content on the page No. 15

PAGE 12 MAINTENANCE (continued) 2. INSPECTIONS AND PREVENTIVE MAINTENANCE REQUIREMENTS To assure satisfactory operation of the pump, daily inspections and periodic maintenance are required. We suggest that an inspection and maintenance log be kept and that the inspector immediately report any problems. A guide for preventive maintenance for normal applications is given below. Unusual applications, with abnormal heat, moisture, dust, etc. may require more frequent inspections

Summary of the content on the page No. 16

MAINTENANCE (continued) PAGE 13 3. BEARING LUBRICATION (continued) Check the oiler setting periodically to be sure it is correct. Refer to the following table for the correct setting. RECOMMENDED OILS: The oil used should be non-detergent type containing rust and oxidation inhibitors, supplied by a reputable manufacturer. Depending on bearing/pump operating temperature, the grade and viscosity should be as follows: o Below 120 F – ISO Vg Grade 40-70 (SAE 20) o 120F to

Summary of the content on the page No. 17

PAGE 14 MAINTENANCE (continued) 5. PACKING REPLACEMENT (continued) PUMP MODEL (PUMP SIZE) 4-441-11A 5-441-18A 2-441-8A 3-441-9A/C 4-441-14C 6-441-14A/C 6-441-19A 4-441-8 5-441-14A 6-441-18A 10-441-20 6-441-12A 8-441-14A PACKING BOX Sleeve O.D. 1-5/8 2 2-1/2 3 3-1/2 Packing Box I.D. 2-7/16 2-15/16 3-9/16 4-3/16 4-13/16 Packing Box Depth 2-15/16 2-7/8 3-7/8 4-5/16 4-3/4 PACKING SIZE 3/8 3/8 1/2 9/16 5/8 Qty. of Rings per Box 7 7 777 (Without Lantern Ring) Lantern Ring Width 3/4 3/4

Summary of the content on the page No. 18

MAINTENANCE (continued) PAGE 15 6. PUMP DISASSEMBLY (continued) E. Remove the capscrews (159D) that secure the bearing housing covers (159) to the bearing housings and remove the housings from the rotating assembly. F. Remove the outer snap ring (345) from the outboard bearing end of the rotating assembly, and use a wheel/bearing puller to remove the outboard (168) and inboard (163) bearings. WARNING: TO PREVENT POSSIBLE SERIOUS PERSONAL INJURY, EXTREME CARE SHOULD BE EXER

Summary of the content on the page No. 19

PAGE 16 MAINTENANCE (continued) 7. PUMP ASSEMBLY CAUTION: READ THIS ENTIRE PROCEDURE BEFORE CONTINUING. Following are step-by-step instructions for assembly of the pump and are essentially the reverse order of the instructions for disassembly. A. Thoroughly clean all parts to remove oil, grease and foreign material. Inspect for wear or damage and replace if required. Remove all parts to a clean and dust-free location for assembly. Gaskets, grease seals and bearings should

Summary of the content on the page No. 20

MAINTENANCE (continued) PAGE 17 7. PUMP ASSEMBLY (continued) Sleeves Secured With Loctite Only: Clean the shaft, the bore of the sleeves and the bore of the impeller with Loctite “Safety Solvent #75559. Install the impeller key in the shaft and coat the impeller area on the shaft with Loctite 601. Press the impeller onto the shaft, centering it between the shoulders as shown in Figure 5. Coat the shaft on the shaft/sleeve fit and the bore of the sleeves with Loctite 601.


Alternative user manuals
# User manual Category Download
1 AURORA PRODUCTS 491 User manual Water Pump 36
2 Edelbrock 25-4066 User manual Water Pump 0
3 A.O. Smith Century Pool & Spa Motor User manual Water Pump 156
4 Agilent Technologies Quaternary Pump 1100 Series User manual Water Pump 33
5 Aero Mist 50 Series User manual Water Pump 0
6 Amtrol GUARDIAN CP DC2 User manual Water Pump 3
7 Aqua Flo A Series User manual Water Pump 12
8 Annovi Reverberi RKA 1750 rpm N Version User manual Water Pump 60
9 Annovi Reverberi RKA 1750 rpm E Version 1-1/8" User manual Water Pump 22
10 Annovi Reverberi RKV 3400 rpm D Version - 1" User manual Water Pump 34
11 Annovi Reverberi HRM-A User manual Water Pump 17
12 Annovi Reverberi RK 1450 rpm N Version User manual Water Pump 46
13 Aqua Flo Therma-Flo EHT User manual Water Pump 2
14 AquaPRO TSC130 PRO User manual Water Pump 19
15 AquaPRO GPH550PRO User manual Water Pump 11