Mad Catz 5MPRA6F-156 user manual

User manual for the device Mad Catz 5MPRA6F-156

Device: Mad Catz 5MPRA6F-156
Category: Water Pump
Manufacturer: Mad Catz
Size: 0.22 MB
Added : 5/11/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mad Catz 5MPRA6F-156. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mad Catz 5MPRA6F-156.

For your convenience

If looking through the Mad Catz 5MPRA6F-156 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mad Catz 5MPRA6F-156 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mad Catz 5MPRA6F-156 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mad Catz 5MPRA6F-156 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mad Catz 5MPRA6F-156 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mad Catz 5MPRA6F-156. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TM
DYNA-GLAS CENTRIFUGAL PUMPS
WITH INTEGRAL TRAP
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
5MPRA Series MODELS
5MPRA6C-146 5MPRA6C3-146
5MPRA6D-147 5MPRA6D3-147
5MPRA6E-148 5MPRA6E3-148
5MPRA6F-156 5MPRA6F3-156
This manual should be furnished to
the end user of this pump; its use will
reduce service calls and chance of
injury and will lengthen pump life.
STA-RITE FOREIGN SALES CORP.
175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA
Telephone: (414) 728-5551; Telefax: (414) 728-446

Summary of the content on the page No. 2

‘5MPRA’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a centrifugal pump. • Is an excellent performer; durable, reliable. Table of Contents Warranty.......................................................................................................2 Safety Instructions ....................

Summary of the content on the page No. 3

READ AND FOLLOW ALL IMPORTANT INSTRUCTIONS! SAFETY This is the safety alert symbol. When you see this symbol on your system INSTRUCTIONS or in this manual, look for one of the following signal words and be alert Always follow basic safety pre- to the potential for personal injury. cautions with this equipment, in- cluding the following. warns about hazards that will cause death, serious personal injury, or major property damage if ignored. To reduce the risk of injury, do not permit children t

Summary of the content on the page No. 4

STRAINER BASKET COVER DISCHARGE PORT NOTICE: Port threads TO FILTER OR POOL are: Internal - 2" NPT for direct connection to pipe. External - 3-1/4" SUCTION Buttress. Fits Sta-Rite PORT U11-200P Union Half FROM POOL for quick disconnect OR pipe connection. VACUUM FILTERS PUMP MAY BE BOLTED TO LEVEL FOUNDATION OR MOUNTING BRACKET Figure 1 INSTALLATION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration

Summary of the content on the page No. 5

Piping: Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter. To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump. To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump. To avoid airlocking, slope suction pipe slightly upward t

Summary of the content on the page No. 6

ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical problem. If GFCI trips and will not reset, have a qualified electrician inspect and repair electrical system. Hazardous voltage. Exact

Summary of the content on the page No. 7

OPERATION NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. If pump is being pressure tested, be sure pressure has been released be- fore removing trap cover. Do not block pump suction. To do so with body may cause severe or fatal injury. Small

Summary of the content on the page No. 8

Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic. For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2. To avoid condensation/corrosion damage, allow ventilation; do not wrap system in plastic. 3. Use a 40% propylene glycol/60% water solution to protect

Summary of the content on the page No. 9

PUMP SERVICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before working on pump or motor. Aside from lubricating trap cover “O” Ring, no lubrication or regular mainte- nance is needed beyond reasonable

Summary of the content on the page No. 10

Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure (Fig. 6). 2. If ceramic seat will not locate properly, remove it, place face up on bench and reclean cavity. Ceramic seat should now locate. 3. If seat still will not locate properly, place a cardboard washer over the polished face and use a piece of 3/4" (19m

Summary of the content on the page No. 11

Clogged pipe/trap/impeller, worn impeller: 7. Make sure suction trap is not clogged; if it is, clean trap and strainer. 8. Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly). 9. Impeller and diffuser may be worn. If so, order replacement parts from Repair Parts List, Page 12. Electrical: 10. Pump may be running too slowly; check voltage at motor

Summary of the content on the page No. 12

1 2 3 BOX A For quick disconnect pipe 4 5 connection parts: 6 Box A 7 Adapter Union Pkg 8 ..................... 11201-0153 8A 8B 12 9 O-Rings (2) .................... 35505-1318 10 23 13 14 11 22 21 20 15A 19 Box A 18 17 16 15B 012 0394 REPAIR PARTS LIST DYNAGLAS POOL PUMP 1/2 through 1-1/2 HP Models Parts are common to all models listed except as Key Part noted: Key Nos. 1, Motor; 8, Impeller; and No. Description Qty. 9, Diffuser are listed below. 1 Motor 115/230 Volt/1 Phase 1 Chart at right


Alternative user manuals
# User manual Category Download
1 Mad Catz 5MPRA6D3-147 User manual Water Pump 0
2 Mad Catz 5MPRA6C-146 User manual Water Pump 0
3 Mad Catz 5MPRA6E-148 User manual Water Pump 0
4 Mad Catz 5MPRA6D-147 User manual Water Pump 0
5 Mad Catz 5MPRA6F3-156 User manual Water Pump 0
6 Mad Catz 5MPRA6E3-148 User manual Water Pump 0
7 Edelbrock 25-4066 User manual Water Pump 0
8 A.O. Smith Century Pool & Spa Motor User manual Water Pump 156
9 Agilent Technologies Quaternary Pump 1100 Series User manual Water Pump 33
10 Aero Mist 50 Series User manual Water Pump 0
11 Amtrol GUARDIAN CP DC2 User manual Water Pump 3
12 Aqua Flo A Series User manual Water Pump 12
13 Annovi Reverberi RKA 1750 rpm N Version User manual Water Pump 60
14 Annovi Reverberi RKA 1750 rpm E Version 1-1/8" User manual Water Pump 22
15 Annovi Reverberi RKV 3400 rpm D Version - 1" User manual Water Pump 34