Desa K36EP user manual

User manual for the device Desa K36EP

Device: Desa K36EP
Category: Indoor Fireplace
Manufacturer: Desa
Size: 2.65 MB
Added : 6/5/2013
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa K36EP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa K36EP.

For your convenience

If looking through the Desa K36EP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa K36EP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa K36EP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa K36EP User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa K36EP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa K36EP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND
INSTALLATION MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
NATURAL GAS
MODELS (V)K36EN
SERIES
PROPANE/LP GAS
MODELS (V)K36EP
SERIES
WARNING: If the information in this manual is not fol-
WARNING: Improper installation,
lowed exactly, a fire or explosion may result causing
adjustment, alteration, service,
property damage, personal injury, or loss of life.
or maintenance can cause injury
or property dama

Summary of the content on the page No. 2

TABLE OF CONTENTS SAFETY INFORMATION 2 TABLE OF CONTENTS CLEANING AND MAINTENANCE ............................................ 26 SAFETY INFORMATION ............................................................ 2 PRODUCT IDENTIFICATION ..................................................... 3 TROUBLESHOOTING .............................................................. 27 LOCAL CODES ........................................................................... 3 REPLACEMENT PARTS ...................

Summary of the content on the page No. 3

SAFETY INFORMATION 3 PRODUCT IDENTIFICATION 3 LOCAL CODES SAFETY INFORMATION PRODUCT IDENTIFICATION Continued Upper Louver Panel Flue Collar 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching. Nailing 6. Carefully supervise young children when they are in the room Flange with fireplace. 7. Do not modify this fireplace under

Summary of the content on the page No. 4

PRODUCT FEATURES PRE-INSTALLATION PREPARATION 4 Location and Space Requirements PRODUCT FEATURES These are a few facts that can help you understand and enjoy your • Your fireplace is designed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against direct-vent fireplace: any exterior surface on the back, sides, or top of your fireplace, • The venting system may be routed to the outside of your home except where standoff spacers are integrally attached

Summary of the content on the page No. 5

PRE-INSTALLATION PREPARATION 5 Clearances 5 Framing and Finishing PRE-INSTALLATION PREPARATION Continued CLEARANCES 3 Minimum clearances to combustibles for the fireplace are as follows: 10 D /8" 5 15" C B 49 /8" Back, and sides 0"/mm 3 35 /4" A Perpendicular walls 6" (152mm) Floor 0"/mm Ceiling to louver opening 42" (1067mm) Front 36" (914mm) 3 E 13 /4" Top 0"/mm F 41" 1 Vent (See venting instructions for G 41 /4" Nailing Tabs specific venting clearances.) 1 68 /2" H Combustible material with a

Summary of the content on the page No. 6

V G G V A D E V B L LOCATION OF TERMINATION CAP 6 LOCATION OF TERMINATION CAP N N H C I B Fixed V V Fixed Closed Openable Closed Openable F B V J G V X B B M A V K X TERMINATION CAP AIR SUPPLY INLET G GAS METER RESTRICTED AREA V X (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (182.9cm) [*12 inches (30.5mc) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mech

Summary of the content on the page No. 7

VENTING INSTALLATION INSTRUCTIONS 7 Installation Precautions 7 VENTING INSTALLATION INSTRUCTIONS NOTICE: Read these instructions completely be- NOTICE: Failure to follow these instructions will void fore attempting installation. the warranty. These models are tested and approved for use with DESA (direct- INSTALLATION PRECAUTIONS vent) pipe components and terminations. • Wear gloves and safety glasses for protection The venting system must terminate on the outside of the structure and • Use extr

Summary of the content on the page No. 8

VENTING INSTALLATION INSTRUCTIONS Installation Planning 8 VENTING INSTALLATION INSTRUCTIONS Continued INSTALLATION PLANNING Female There are two basic types of direct-vent installation: Locking Lugs • Horizontal Termination • Vertical Termination Male Horizontal Termination Installation Slots IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Horizontal installations using round termina- tion require exterior portion of wall firestop (see Figure 14, page 10).

Summary of the content on the page No. 9

VENTING INSTALLATION INSTRUCTIONS 9 Installation Planning (Cont.) 9 VENTING INSTALLATION INSTRUCTIONS Continued WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. Cut Siding Away to Fit Standoff 6. Noncombustible Exterior Wall: Position the horizontal vent 1 Standoff cap in the center of the 8 /2" round hole and attach to the exte- rior wall with four wood screws provided. Before attaching Wood Screw the vent cap to exterior wall, run a bead of non-hardening m

Summary of the content on the page No. 10

VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 10 VENTING INSTALLATION INSTRUCTIONS Continued 10. Place fireplace into position and shim with noncombustible ma- terial if needed. Nail or screw side flanges to framing to secure WARNING: Never run vent downward as this may unit in place. IMPORTANT: Make sure fireplace is level before cause excessive temperatures which could cause a securing. If fireplace is not level it will not work properly. fire. Operation of improperly install

Summary of the content on the page No. 11

VENTING INSTALLATION INSTRUCTIONS 11 Installation Planning (Cont.) 11 VENTING INSTALLATION INSTRUCTIONS Continued Vertical (V) Required CORNER INSTALLATION Vertical (V) Vertical Pipe Horizontal (H) 1 Recommended Applications: *43 /2" min. None 30" max. 1 54 /2" min. 1 ft. 48" max. • Corner ground floor installation 1 66 /2" min. 2 ft. 60" max. 1 • Ground floor installation where pipe vents horizontally through wall 78 /2" min. 3 ft. 84" max. 1 (over 12" horizontal pipe) 90 /2" min. 4 ft. 20' max

Summary of the content on the page No. 12

VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 12 VENTING INSTALLATION INSTRUCTIONS Continued HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. Venting with Two 90° Elbows Horizontal (H ) + 1 Vertical (V) Horizontal (H ) Horizontal (H ) 1 2 45° Elbow 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' max. 20' max. 20' max. 8'

Summary of the content on the page No. 13

VENTING INSTALLATION INSTRUCTIONS 13 Installation for Vertical Termination 13 VENTING INSTALLATION INSTRUCTIONS Continued 2. Assemble the desired lengths of pipe and elbows necessary to INSTALLATION FOR VERTICAL TERMINATION reach from the fireplace flue up through the firestop. Be sure Note: Vertical restrictor must be installed in all vertical installations. all pipe and elbow connections are fully twist-locked (see Fig- 1. Determine the route your vertical venting will take. If ceiling ure 8,

Summary of the content on the page No. 14

VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination (Cont.) 14 VENTING INSTALLATION INSTRUCTIONS Continued Venting with One 90° Elbow Vertical Termination Configurations Vertical (V) Horizontal (H) Figures 21 through 24 show four different configurations for verti- 5' min. 2' max. cal termination. 6' min. 4' max. 7' min. 6' max. Venting with Two 90° Elbows 8' min. 8' max. Vertical (V) Horizontal (H ) + 1 20' max. 8' max. Horizontal (H ) 2 45° Elbow Note: Install restrict

Summary of the content on the page No. 15

VENTING INSTALLATION INSTRUCTIONS 15 Installation for Vertical Termination (Cont.) 15 High Altitude Installation VENTING INSTALLATION INSTRUCTIONS Continued HIGH ALTITUDE INSTALLATION Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada) . When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller si

Summary of the content on the page No. 16

VENTING INSTALLATION INSTRUCTIONS Parts Lists for Venting Kits and Components 16 FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory VENTING INSTALLATION FIREPLACE INSTALLATION INSTRUCTIONS CHECK GAS TYPE Continued Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where PARTS LISTS FOR VENTING KITS AND you purchased the fireplace for proper fireplace according to your COMPONENTS gas type

Summary of the content on the page No. 17

FIREPLACE INSTALLATION 17 Installing Optional Blower Accessory (Cont.) 17 FIREPLACE INSTALLATION Continued 4. Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight. 5. Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning

Summary of the content on the page No. 18

FIREPLACE INSTALLATION Installing Optional Blower Accessory (Cont.) 18 Installing Gas Piping to Fireplace Location FIREPLACE INSTALLATION Continued 3. Place the blower against the lower rear wall of the firebox outer INSTALLING GAS PIPING TO FIREPLACE wrapper with the exhaust port directed upward and the thermodisc LOCATION positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28, page WARNING: A qualified service person must con-

Summary of the content on the page No. 19

FIREPLACE INSTALLATION 19 Installing Gas Piping to Fireplace Location (Cont.) 19 Connecting Fireplace To Gas Supply Checking Gas Connections FIREPLACE INSTALLATION Continued CONNECTING FIREPLACE TO GAS SUPPLY CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- Installation Items Needed tain areas. Check your local codes. Use pipe of 1/2" • 5/16" hex socket wrench or nut-driver inside diameter or greater to allow proper gas volume • sealant (resis

Summary of the content on the page No. 20

FIREPLACE INSTALLATION Checking Gas Connections (Cont.) 20 Removing/Replacing Glass Door FIREPLACE INSTALLATION Continued 4. Check all joints of gas supply piping system. Apply noncorro- Pressure Testing Fireplace Gas Connections sive leak detection fluid to all joints. Bubbles forming show a 1. Open equipment shutoff valve (see Figure 33, page 20). leak. Correct all leaks at once. 2. Open propane/LP supply tank valve for propane/LP fireplace 5. Reconnect fireplace and equipment shutoff valve to


Alternative user manuals
# User manual Category Download
1 Desa (V)368ST User manual Indoor Fireplace 0
2 Desa (V)B36L User manual Indoor Fireplace 0
3 Desa (V)C36 User manual Indoor Fireplace 0
4 Desa (V)C36H User manual Indoor Fireplace 1
5 Desa (V)B36LI User manual Indoor Fireplace 0
6 Desa (V)C36I User manual Indoor Fireplace 1
7 Desa (V)B36I User manual Indoor Fireplace 1
8 Desa (V)C36L User manual Indoor Fireplace 0
9 Desa (V)B36 User manual Indoor Fireplace 4
10 Desa (V)C36LH User manual Indoor Fireplace 0
11 Desa (V)C36LI User manual Indoor Fireplace 0
12 Desa (V)CB36N(E) User manual Indoor Fireplace 0
13 Desa (V)CB36P(E) User manual Indoor Fireplace 0
14 Desa (V)DVF36 User manual Indoor Fireplace 2
15 Desa (V)G36 User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1