Lennox Hearth Radium-NG user manual

User manual for the device Lennox Hearth Radium-NG

Device: Lennox Hearth Radium-NG
Category: Indoor Fireplace
Manufacturer: Lennox Hearth
Size: 1.58 MB
Added : 4/27/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lennox Hearth Radium-NG. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lennox Hearth Radium-NG.

For your convenience

If looking through the Lennox Hearth Radium-NG user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lennox Hearth Radium-NG on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lennox Hearth Radium-NG to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lennox Hearth Radium-NG User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lennox Hearth Radium-NG but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lennox Hearth Radium-NG. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION AND OPERATION MANUAL
TM
Catalytic Vent-Free
Wall-Mounted Gas Fireplace
Models: Radium-NG and Radium-LP
P/N 850,054M REV. E, 11/2008
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
A Spanish manual is available upon request. Order P/N 850,054LS.
Este manual está disponible en espanol por solicitud. Pida P/N
850,054LS para la versión en espanol.
In the Commonwealth of Massachusetts:
Portland
• Installation must be performed by

Summary of the content on the page No. 2

• Children and adults should be alerted to the hazard of high 1.0 IMPORTANT SAFETY AND WARNING surface temperature and should stay away to avoid burns or clothing ignition. INFORMATION • Young children should be carefully supervised when they are in the same room with the heater. WARNINGS • Do not place clothing or other flammable material on or near the heater. If the information in this manual is not fol- • Any safety screen or guard removed for servicing the heater lowed exactl

Summary of the content on the page No. 3

These heaters are fitted with a specially designed pilot utilizing an CONGRATULATIONS ON THE PURCHASE OF YOUR NEW oxygen depletion sensor (ODS) which responds to the amount of GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH oxygen available in the room and shuts the heater off before the PRODUCTS. oxygen level drops below 18%. It must not be adjusted or put out of operation. If replaced then manufacturers original parts must be When you purchased your new gas fireplace, you joined the ranks o

Summary of the content on the page No. 4

Massachusetts Requirements 5.0 UNPACKING THE APPLIANCE These fireplaces are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: Remove the straps and the top lid of the outer packaging, remove any instructions or fixing kits. Read ALL these instructions before continuing • Unvented Room Heaters shall be installed in accordance with 527 to unpack or install this appliance. CMR 30.00 and 248 CMR 3.00 through 7.00: Lift off the remainin

Summary of the content on the page No. 5

Example: 8.0 COMBUSTION AND VENTILATION AIR Vent-free heater #1 9,000 BTU/Hr Vent-free heater #2 23,000 BTU/Hr Gas appliance #1 35,000 BTU/Hr This heater shall not be installed in a confined space or unusually tight (water heater) construction unless provisions are provided for adequate combustion and Total = 67,000 BTU/Hr ventilation air. The heater may be located in unusually tight construction provided the space is unconfined, or

Summary of the content on the page No. 6

The minimum clearance to the ceiling above the appliance is 32” measured 9.0 SITE REQUIREMENTS from the top of the appliance glass panel. Combustible materials should not be positioned directly in front of the This appliance is designed to be wall-hung. Do not recess any part of appliance within a distance of 40”. the appliance into the wall. Under no circumstances should any electrical equipment e.g. plasma This appliance may be installed in any room in a home except bathrooms screen TV se

Summary of the content on the page No. 7

(RS) Revise "fiber wall plug" to read "wall plug" . The correct sized hole that the installer will need to drill (if he is going to use the plugs) is diameter 8mm to a depth of 42mm. (done 1-29-08) Non-concealed gas connections may be made using the entry points To ensure customer safety, be sure to design the installation so that the at either end of the firebox or the one in the bottom of the firebox. A strength of both the wall and any wall fixings used are sufficient. Lennox concealed ga

Summary of the content on the page No. 8

11.0 MOUNTING THE APPLIANCE - continued IMPORTANT Hold heater regulator with a wrench to prevent move- Insert the wall mounting screws into the top wall plugs, taking ment when connecting to inlet piping. care to leave the screws protruding approximately 3/8” from the wall. Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance. A qualified gas appliance installer must connect the gas room heater to the gas supply. Consult all

Summary of the content on the page No. 9

replace the burner assembly (see Page 15 for ordering information). The valve is found on the center of the appliance behind the valve 14.0 CHECKING THE GAS CONNECTIONS cover. Remove the cover plate by unscrewing the four retaining screws. Release the test point screws and ensure operating pressures are as specified in Table 1 on Page 3 of these instructions. The pressure WARNING should be checked with the gas heater burning and the control set to high flame. Never use an open flame

Summary of the content on the page No. 10

16.0 SPARK GAP Damper The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark. There should be no need to adjust this (DO NOT ATTEMPT TO ADJUST THE GAP). If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually. Adjustment to the 1/8" to 3/16" Spark Gap pilot is Not allowed Figure 7b Figure 6 - Proper Spark Gap Fixing hole 17.0 FITTING THE GLASS FACIA The glass panel is supported by two self-locking M6 screws, one

Summary of the content on the page No. 11

First, remove the front glass facia as described in Section 17.0 only in 19.0 SERVICING reverse, remove the valve cover (4 screws) and disconnect the gas con- nection inside appliance. The gas connections to the gas valve can now be released. Undo the four screws retaining the burner brackets to the WARNING base and rear of the firebox. The burner may now be removed. Turn off the appliance and allow to cool before cleaning. Remove the pilot and main burner pipes and blow through to dis

Summary of the content on the page No. 12

Turn on the fireplace as per the operating instructions, and run at maximum .0 CATALYSTS setting for 15 minutes. Position gas sample probe directly over a catalyst via the outlet grill, on top of the appliance. Record the carbon dioxide (CO ) concentration and then the carbon monoxide (CO) concentration WARNING as displayed by the analyzer - also noting the units in which the values are expressed. Most analyzers display carbon dioxide (CO ) concentra- Do not block the catalysts

Summary of the content on the page No. 13

5.0 LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. • Immediately call your gas supplier from a neighbor’s phone. A. T his appliance has a pilot which must be lit with a piezo spark Follow the gas supplier’s instructions. igniter. When lighting the pilot, follow these instructions exactly.

Summary of the content on the page No. 14

6.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer. • Spark grounding to metal work, reset gap correctly. • Blocked pilot, clean out internally. Pilot lights but then goes out • Severe restriction in gas supply: clear obstruction. • Faulty thermocouple, replace pilot assembly. • Blocked pilot, clean out. • Blocked lint gauze, clean. • Hold c

Summary of the content on the page No. 15

FocalPointFires Single 24/04/08 DO 005850/0 Lennox L30 Radium fitting template Artwork Size: W900 x H690 POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED 7.0 REPLACEMENT P  ARTS - RADIUM™ 16” (406mm) 13-3/4” (350mm) FIXING POINTS: WHEN MOUNTING PLATE IS NOT USED PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4 PUNTOS DE SUJECION: SI NO SE UTILIZA LA PLACA DE MONTAJE PERFORE L

Summary of the content on the page No. 16

8.0 POSITIONING OF FIELD REMOVABLE PARTS Glass Door Removal: Remove Removal and refitting of glass door WARNING the four (4) screws indicated, assembly and burner assembly. then lift door off. Failure to position the parts in accordance with these diagrams or failure to use only parts specifi- cally approved with this heater may result in property damage or personal injury. Visual check for cor- rect pilot flame. As our policy is one of continuous improvement and development, w

Summary of the content on the page No. 17

9.0 SPECIFICATIONS Product Reference Information Cat. No. Model Ship. Wt. Ship. Volume H6064 Radium-NG 75 lb. 1 .9 cu. ft. H6070 Radium-LP 75 lb. 1 .9 cu. ft. Top View 7-3/16” 35-7/16” OPEN CLOSED 20-7/8” 3-1/8” 27-3/16” 11-1/4” 19-7/16” 23” Front View Side View 13-3/4” CTRS 18” CTRS Back View NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 17

Summary of the content on the page No. 18

30.0 PRODUCT REFERENCE INFORMATION WARRANTY Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your gas appliance is covered by a limited warranty. Please read the warranty to be familiar with its coverage. When ordering repair parts, always give the following information: Retain this manual. File it with your other documents for future refer- 1. The model number of the appliance. ence. .  The serial n


Alternative user manuals
# User manual Category Download
1 Lennox Hearth 36" and 42" Wood Burning Fireplaces BR-36/42 User manual Indoor Fireplace 1
2 Lennox Hearth 36" and 42" Wood Burning Fireplaces BCI-36/42 User manual Indoor Fireplace 1
3 Lennox Hearth 36" and 42" Wood Burning Fireplaces BRI-36/42-2 User manual Indoor Fireplace 0
4 Lennox Hearth 36" and 42" Wood Burning Fireplaces BC-36/42 User manual Indoor Fireplace 2
5 Lennox Hearth 36" and 42" Wood Burning Fireplaces BRI-36/42 User manual Indoor Fireplace 3
6 Lennox Hearth 36" and 42" Wood Burning Fireplaces BC-36/42-2 User manual Indoor Fireplace 0
7 Lennox Hearth 36" and 42" Wood Burning Fireplaces BCI-36/42-2 User manual Indoor Fireplace 0
8 Lennox Hearth 36" and 42" Wood Burning Fireplaces BR-36/42-2 User manual Indoor Fireplace 0
9 Lennox Hearth 875027M User manual Indoor Fireplace 0
10 Lennox Hearth Adagio ADAGIO-EN User manual Indoor Fireplace 0
11 Lennox Hearth 4.5HTSK User manual Indoor Fireplace 0
12 Lennox Hearth Adagio ADAGIO-MP User manual Indoor Fireplace 0
13 Lennox Hearth Adagio ADAGIO-MN User manual Indoor Fireplace 0
14 Lennox Hearth ADAGIO-IG H5776 User manual Indoor Fireplace 0
15 Lennox Hearth ADK22CMBS User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1