Superior CDCL-CMN user manual

User manual for the device Superior CDCL-CMN

Device: Superior CDCL-CMN
Category: Indoor Fireplace
Manufacturer: Superior
Size: 4.52 MB
Added : 11/29/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Superior CDCL-CMN. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Superior CDCL-CMN.

For your convenience

If looking through the Superior CDCL-CMN user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Superior CDCL-CMN on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Superior CDCL-CMN to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Superior CDCL-CMN User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Superior CDCL-CMN but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Superior CDCL-CMN. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION
INSTRUCTIONS
DIRECT VENT
MULTI-OPEN SERIES
This appliance may be installed in an aftermar-
VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS
ket permanently located, manufactured home
P/N 700,001M REV. H 09/2005
(USA only) or mobile home, where not prohib-
ited by local codes. This appliance is only for
MODELS
use with the type of gas indicated on the rating
plate. This appliance is not convertible for use
Ms illivolt Models Electronic Model
with other gases, unless a certified

Summary of the content on the page No. 2

PACKAGING GENERAL INFORMATION TABLE OF CONTENTS The assembled vented gas fireplace heater is Packaging ........................................ page 2 packaged with: Note: Installation and repair should be per- formed by a qualified service person. The appli- Introduction ..................................... page 2 1 - one cartoned log set located in firebox area; ance should be inspected annually by a quali- General Information ......................... page 2 decorative volcanic stone and g

Summary of the content on the page No. 3

Electronic Models - This appliance may be installed in an af- WARNING: FAILURE TO COMPLY WITH Electronic models have a fixed rate gas valve. termarket permanently located, manufac- THE INSTALLATION AND OPERATING IN- Input of electronic models is shown in the tured home (USA only) or mobile home, STRUCTIONS PROVIDED IN THIS DOCU- following table: where not prohibited by local codes. This MENT WILL RESULT IN AN IMPROP- appliance is only for use with the type of Electronic Models ERLY INSTALLED A

Summary of the content on the page No. 4

Corner - Left Corner - Right (CDCL) (CDCR) See-Through (CDST) VERTICAL VENT HORIZONTAL VENT HORIZONTAL VENT Peninsula - REAR - TOP (CDPF) See-Through one side flush with a wall (CDST) - TYPICAL LOCATIONS Figure 2 The appliance should be mounted on a fully Shelf Height inches (mm) supported base extending the full width and Model No. Tk op Vent - with One 90 Degree Elbow Rear Vent - Straight Out the Bac depth of the unit. The appliance may be located on or near conventional construction materi-

Summary of the content on the page No. 5

3 - Lift the pressure relief plates and remove All framing details must allow for a mini- TYPICAL INSTALLATION SEQUENCE mum clearance to combustible framing the cardboard from underneath each of them. The typical sequence of installation follows, members as shown inTable 2 on page 4. however, each installation is unique resulting in 4 - Open the control compartment access panel Note: The CDST fireplace is installed in the variations to those described. by actuating the spring loaded magnetic ca

Summary of the content on the page No. 6

V EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS * See Item D in the Text Below. Center Line Exterior Wall of Termination Inside Corner Detail *18” Horizontal G Termination 18” V Ventilated Soffit A Inside Corner = 9” in U.S. A = 12” in Canada Detail D H 3 ft. B B D E X C A A V Fixed V L V Operable Closed Window 3 ft. Window V F C B J V M C B C B V I A X = Air Supply Inlet V = Vent Terminal = Area where Terminal is not Permitted C* anadian Installation* US Installation* A = Clearanc

Summary of the content on the page No. 7

FIREPLACE FRAMING SPECIFICATIONS inches (millimeters) inches (millimeters) CDST CDPF (Peninsula) 11³⁄₈ 11³⁄₈ Minimum Framing Minimum Framing (See-Through) Stud Size is 2x4 Stud Size is 2x4 10¹⁄₂ 10¹⁄₂ (267) (267) VENT FRAMING - VENT FRAMING - TOP VENT WITH TOP VENT WITH ONE 90º ELBOW ONE 90º ELBOW VENT FRAMING - VENT FRAMING - REAR VENT WITH 7 REAR VENT WITH 7 (178) NO ELBOWS (178) NO ELBOWS 12¹⁄₈ 12¹⁄₈ (308) (308) 7 7 (178) (178) 5¹⁄₈ 5¹⁄₈ (130) (130) 12¹⁄₈ 12¹⁄₈ (308) (308) A 5¹⁄₈ A 5¹⁄₈ 26³⁄₄

Summary of the content on the page No. 8

FIREPLACE SPECIFICATIONS 10 FINISH WALL BRACKET CDST (See-Through) (Front and back edge of unit top) (254) 12 (305) 1/2 FRAMING SPACERS (13) NOTE - Unit has a factory-installed (Top and Both Sides) vent sea cap and vent cover plate (see Figures 17 and 18 on page 10) FLUE in each flue outlet. The vent seal (Top or Side) cap is not shown in this figure. ⁵⁄₈ (16) DETAIL OF 40¹⁄₈ FINISH WALL 3¹⁄₂ (89) (1019) Stepped to Accept Drywall on All 4 Corners BRACKET 3¹⁄₂ (89) TOP VIEW 2¹⁄₂ ¹⁄₂ (13) ¹⁄₂ (13

Summary of the content on the page No. 9

FIREPLACE SPECIFICATIONS CONTINUED 9¹⁄₄ CDCL (Corner-Left) OPTIONAL GAS INLET (235) 10 FRAMING SPACERS (254) (Top, Side and Back) NOTE - Unit has a factory-installed vent seal cap and vent cover plate (see Figures 17 and 18 on page 10) 12 FLUE in each flue outlet. The vent seal cap (305) (Top or Side) is not shown in this figure. DETAIL OF FINISH WALL BRACKET ¹⁄₂ FINISH WALL BRACKET (13) (Front and left edge of unit top) ⁵⁄₈ (16) 40¹⁄₈ Stepped to (1019) 3¹⁄₂ Accept (89) Drywall TOP VIEW 2¹⁄₂ ¹⁄₂

Summary of the content on the page No. 10

When the top vent collar is being used, from Preparing the Appliance Top or Rear Vent Step 2. ROUTING GAS LINE inside the firebox, loosen the two screws in the Outlet when vertically terminating the vent Route a ¹⁄₂" (13 mm) gas line as shown in Figure keyhole slots of the cover plate and remove the system above the roof 9 (CDST), 10 (CDPF), 11 (CDCL) or 12 (CDCR) remaining two cover plate securing screws. on pages 8 and 9. Gas lines must be routed, A vent restrictor may be needed with this Rem

Summary of the content on the page No. 11

VERTICAL TERMINATION SYSTEMS (ROOF) VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART Nominal T T Nominal Section 62142638 4 Section Length 62142638 4 O O Length (inches) Figure 21, and Figures 32 through 36 on (inches) T T Net Section A A 42 -1/212 0-1/22 2-1/32 4-1/ 46-1/ Net Section pages 14 and 15 and their associated Vertical Length (inches) 42 -1/212 0-1/22 2-1/32 4-1/ 46-1/ L L Length (inches) Vent Tables illustrate the vertical venting con- Hs eight of Vent Number of Vent Section Hs e

Summary of the content on the page No. 12

Vertical (Offset) Installation The dimpled end of the vent components fit over This seating position is indicated by the align- the appliance collar to create the positive twist ment of the arrow and dimple as shown in Analyze the vent routing and determine the lock connection. Figure 24. number of vent sections and elbows required. D. Install firestop/spacer at ceiling - When Refer to Vertical Vent Figures and Tables on First Vent using Secure Vent, use SV4.5VF firestop/spacer Component page 1

Summary of the content on the page No. 13

Use a carpenter’s level to measure from a J. Install the storm collar - Install the storm SV4.5CGV-1 Termination SV4.5FA OR constant surface and adjust the support straps collar, supplied with the flashing, over the vent/ SV4.5FB Flashing as necessary. flashing joint. See Figure 30. Loosen the storm AND SV4.5SC STORM COLLAR collar screw. Slide collar down until it meets the It is important to maintain the required clear- top of the flashing. Tighten the adjusting screw. 1" (25.4 mm) Minimum Clea

Summary of the content on the page No. 14

VERTICAL VENT FIGURES/TABLES *When using Secure Flex, *Ceiling use Firestop/Spacer Note: Secure Vent (rigid vent pipe) is shown TABLE A Firestop/Spacer SF4.5VF in the figures; Secure Flex (flexible vent pipe) (SV4.5VF) **When using Secure VMINIMUM H Maximum Flex, use Firestop/Spacer may also be used (see page 21). SF4.5HF f) eet(t m f) ee (m **Wall WARNING: UNDER NO CIRCUM- Firestop/Spacer 1)(2 0.305 (0.61) (SV4.5HF) STANCES MAY SEPARATE SECTIONS V 2)(4 0.61 (1.222) OF CONCENTRIC FLEXIBLE VE

Summary of the content on the page No. 15

VERTICAL VENT FIGURES/TABLES (continued) *When using Secure Flex, TABLE C H1 use Firestop/Spacer SF4.5VF Vm MinimumHH Maximu H+ Maximum 1 **When using Secure *Ceiling f) eet(t mf) ee(t mf) ee (m Firestop/Spacer Flex, use Firestop/Spacer (SV4.5VF) SF4.5HF 1)(2 0.305 (5 0.610) (1.52) A Vent Restrictor, as 2)(4 0.610 (0 1.22)1) (3.1 shown in Figure 20, page 10, may be used in 3)(6 0.914 (5 1.86)1) (4.65 this application **Wall 4)(8 1.22 (0 2.48)2) (6.2 Firestop/Spacer (SV4.5HF) **Wall V+V +H+H = 40

Summary of the content on the page No. 16

HORIZONTAL (OUTSIDE WALL) TYPICAL HORIZONTAL VENT INSTALLATION TERMINATION SYSTEM Support Building Horizontal / Inclined Run Brackets Figure 37, and Figures 40 to 46 on page 18 to Support SV4.5 HT Framing Termination 20 and their associated Horizontal Vent Table illustrate the horizontal venting configurations SV4.5E90 Elbow that are allowed to be used with these appliances. Secure Vent pipe applications are shown in these figures; Secure Flex pipe may also be used. See SV4.5L6/12/24/36/48 Exter

Summary of the content on the page No. 17

J. Assemble vent run to exterior wall - If not Firestop/Spacer (SV4.5HF) shown previously measured, locate the center of the on the exterior side of the wall. It vent at the exterior wall. Prepare an opening as may also be installed on the interior side. SV4.5HT described in Step B. Assemble the vent system Termination to point where the terminus of the last section is 7" (178) within 7¹⁄₂ in. (191 mm) to 11³⁄₄ in. (298 mm) 12¹⁄₈" 10¹⁄₂" inboard of the exterior surface to which the (308 mm) (2

Summary of the content on the page No. 18

HORIZONTAL VENT FIGURES/TABLES TABLE E Note: Secure Vent components (rigid vent pipe and terminal) are shown in the figures; Secure Flex components (flexible vent pipe and terminal) may V = 0ne 90 degree elbow also be used. H = 3 feet (0.914 m) Max. Note: Two 45 degree elbows may be used in place of one 90 degree elbow. The same rise to run ratios, as shown in the venting figures for 90 elbows, H must be followed if 45 degree elbows are used. V Note: It is very important that the horizontal

Summary of the content on the page No. 19

HORIZONTAL VENT FIGURES/TABLES (continued) TABLE G H Vm MinimumHH Maximu H+ Maximum H 1 1 f) eet(t m f) ee (t m f) ee (m 1)(2 0.305 (5 0.610) (1.52) 2)(4 0.610 (0 1.22)1) (3.1 **Wall Firestop/Spacer (SV4.5HF) 3)(6 0.914 (5 1.86)1) (4.65 *Ceiling 4)(8 1.22 (0 2.48)2) (6.2 Firestop/Spacer V+H+H = 40 feet (12.4 m) Max. (SV4.5VF) 1 H = 8 feet (2.48 m) Max. V H + H = 20 feet (6.2 m) Max. 1 **Wall Firestop/Spacer (SV4.5HF) *When using Secure Flex, use Firestop/Spacer SF4.5VF **When using Secure Flex,

Summary of the content on the page No. 20

HORIZONTAL VENT FIGURES/TABLES (continued) **Wall Firestop/Spacer (SV4.5HF) *When using Secure Flex, use Firestop/Spacer SF4.5VF H **When using Secure 1 Flex, use Firestop/Spacer SF4.5HF H 2 TABLE J **Wall Firestop/Spacer (SV4.5HF) H+H +H *Ceiling Firestop/Spacer 1 2 Vm Minimum H Maximu (SV4.5VF) Maximum f) eet(t m f) ee (t m f) ee (m V 1)(2 0.305 (5 0.610) (1.52) 2)(4 0.610 (0 1.22)1) (3.1 3)(6 0.914 (5 1.86)1) (4.65 H 4)(8 1.22 (0 2.48)2) (6.2 V+H+H +H = 40 feet (12.4 m) Max. 1 2 H = 8 feet (2


Alternative user manuals
# User manual Category Download
1 Superior 36" B-VENTED GAS APPLIANCES B-40REP User manual Indoor Fireplace 2
2 Superior 36" B-VENTED GAS APPLIANCES B-40RMP User manual Indoor Fireplace 1
3 Superior 600 User manual Indoor Fireplace 5
4 Superior 36" B-VENTED GAS APPLIANCES B-40RMN User manual Indoor Fireplace 1
5 Superior ARCHED FACE KITS SDVI User manual Indoor Fireplace 1
6 Superior 800 User manual Indoor Fireplace 3
7 Superior BC-36-2 User manual Indoor Fireplace 2
8 Superior BR-36-2 User manual Indoor Fireplace 9
9 Superior BC-36 User manual Indoor Fireplace 67
10 Superior br-36 User manual Indoor Fireplace 3
11 Superior BCD36MH User manual Indoor Fireplace 10
12 Superior BC36MH User manual Indoor Fireplace 2
13 Superior BCI-36 User manual Indoor Fireplace 1
14 Superior 500 User manual Indoor Fireplace 2
15 Superior CDCL-CEN User manual Indoor Fireplace 1
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1