Lennox Hearth Crestline LSBV-3628MP user manual

User manual for the device Lennox Hearth Crestline LSBV-3628MP

Device: Lennox Hearth Crestline LSBV-3628MP
Category: Indoor Fireplace
Manufacturer: Lennox Hearth
Size: 1.06 MB
Added : 3/6/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lennox Hearth Crestline LSBV-3628MP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lennox Hearth Crestline LSBV-3628MP.

For your convenience

If looking through the Lennox Hearth Crestline LSBV-3628MP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lennox Hearth Crestline LSBV-3628MP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lennox Hearth Crestline LSBV-3628MP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lennox Hearth Crestline LSBV-3628MP User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lennox Hearth Crestline LSBV-3628MP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lennox Hearth Crestline LSBV-3628MP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION
INSTRUCTIONS

CRESTLINE SERIES
B-VENTED GAS APPLIANCES
P/N 850,042M REV. A 12/2008
LENNOX HEARTH PRODUCTS
MODELS
This appliance may be installed in an aftermarket perma-
Millivolt Models Electronic Models
nently located, manufactured home (USA only) or mobile
LSBV-3628MN LSBV-3628EN
home, where not prohibited by local codes. This appliance
LSBV-3628MP LSBV-3628EN-H
is only for use with the type of gas indicated on the rating
LSBV-3628MN-H LSBV-4228EN
plate. This appliance is no

Summary of the content on the page No. 2

3 - one envelope containing the literature Massachusetts: TABLE OF CONTENTS package which consists of the homeowner's Installation of these fireplaces are approved manual, installation instructions, and war- for installation in the US state of Massachu- Packaging ........................................ page 2 ranty; envelope is located in the control area. setts if the following additional requirements Introduction ..................................... page 2 are met- Massachusetts and New York

Summary of the content on the page No. 3

Nominal operating pressures for the manifold The appliance and its individual shut-off valve WARNING: CHILDREN AND ADULTS side of the gas control system are; 3.5 inches must be disconnected from the gas supply SHOULD BE ALERTED TO THE HAZARDS water column (0.87 kPa) for natural gas mod- piping system during any pressure testing of OF HIGH SURFACE TEMPERATURES. USE els and 10 inches water column (2.49 kPa) for that system at pressures in excess of 1/2 psig CAUTION AROUND THE APPLIANCE TO propane

Summary of the content on the page No. 4

The appliance should be mounted on a fully APPLIANCE SPECIFICATIONS supported base extending the full width and depth of the unit. The appliance may be located 12-15/32 on or near conventional construction materi- als. However, if installed on combustible mate- rials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom 7-3/32 surface must be used. These appliances may be used for bedroom installations in the United States and are listed accordingly. These uni

Summary of the content on the page No. 5

ASSEMBLY STEPS FRAMING SPECIFICATIONS Back Wall of Chase/Enclosure The typical sequence of installation follows, Including Finishing Materials FOAK-4 if any however, each installation is unique resulting Combustion Air Kit in variations to those described. D 1. Construct the appliance framing. K F G 2. Route gas supply line to appliance location. C 3. Position the appliance. Header A E Rough 4. Install the vent system and exterior termina- Framing Face (Unfinished Shown) tion. Corner Installatio

Summary of the content on the page No. 6

4. Use this information and consult your local Ensure that a sediment trap is installed in the Step 3. Position the Appliance - Slide the building code to determine if you need addi- existing gas line, if not, install a sediment trap fireplace into prepared framing or position fire- tional support. upstream to prevent moisture and contami- place in its final position and frame later. nants from passing through trap to the appli- If you plan to raise the fireplace and hearth ance controls and bur

Summary of the content on the page No. 7

TP TH TP TH Step 4. Install the Vent System & Exterior Termination - Slip a 10" (254 mm) B-Vent system over the appliance collar (Figure 10 ) and secure with four sheetmetal screws (# 8 or larger). 45 degrees max. Minimum overall height of the vent system and appliance must be 12' (3.66 m) vertical 17 ft. 12 ft. (no offset) or 17' (5.18 m) when an offset up Minimum Minimum to 45 degrees from the vertical is used. The 3 ft. lower part of the offset must not begin less Minimum than 3' (0.914 m) a

Summary of the content on the page No. 8

PILOT BURNER WHITE ELECTRONIC WIRING DIAGRAM IGNITER-SENSOR ASSEMBLY EV2 EV1 Plug blower into this Green GAS VALVE White receptacle Ground - Green Neutral - White BLUE 120 VAC - Black Black GROUND Junction Box Ta b Broken CONNECTOR Tab Intact BLACK Red Green WHITE Neutral Hot Ground Side of Side of Screw GREEN LED Receptacle Receptacle BK W TRANSF 120 V. ELECTRONIC IGNITION CONTROL BOARD 24 V. DAMPER SWITCH LIMIT SWITCH BLACK BLACK BLACK CONNECTOR WALL MOUNTED ON/OFF SWITCH Figure 13 1. Route a

Summary of the content on the page No. 9

Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however CAUTION: NEVER LOCATE INLET OF AN OUT- the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where SIDE AIR HOOD WHERE IT CAN BE BLOCKED the white supply wire is connected (Figure 15 ). BY SHRUBS, SNOW DRIFTS, ETC. NEVER LOCATE INLET IN GARAGE OR ANY AREA WHERE THERE IS ANOTHER FUEL BURNING APPLIANCE OR PRODUCTS EMITTING COM- BUSTIBLE GASES SUCH AS PAINT

Summary of the content on the page No. 10

MANUALLY-RESET BLOCKED FLUE SAFETY SWITCH This appliance is equipped with a manually- reset blocked flue safety switch. Refer to Figure 19 for its location. If during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool. Then reset the safety switch by pushing the red reset button. This reset button is located on the back of the limit switch, between the wire ter

Summary of the content on the page No. 11

Millivolt Appliance Checkout Step 10. Adjustments – The following para- Adjustment graphs address adjustment concerns and pro- The pilot flame should be steady, not lifting or cedures. To adjust the flame, position the air shutter to floating. Flame should be blue in color with the nominal setting (Figure 22 ). Allow the traces of orange at the outer edge. Flame Appearance and Sooting burner to operate for at least 30 minutes. Observe the flame continuously. If it appears The top 3/8" (9 mm) at

Summary of the content on the page No. 12

INSTALLATION ACCESSORIES Finished Wall Combustible Non Mantel and Trim Combustible Header The following accessory items are available for (See Note) Material Sheet Metal use in the installation of this appliance. 1-3/8" Spacer 12" Top Of Fireplace 5" Max. 18 5/8" 11-3/8" Min. 18" 3 Sheet Metal Screws #10 x 3/4" Max. Flat Head 12" Length 10KL1 12" 24" Length 10KL2 Min. 10" Min. 36" Length 10KL3 Fireplace Opening Security 10" B-vent Adjustable Length 10KAL Non-Combustible Material Note: Mantel At

Summary of the content on the page No. 13

Following Components Are Not Illustrated INSTALLATION ACCESSORIES Outside Air Kits Models FOAK-4 and FOAK-4LD CONTINUED Anchor Plate 10SP Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) Radiation Shield 10RS for use if outside combustion air is re- quired or desired. If model FOAK-4LD is Roof Brace XBS2 used it must be used in conjunction with locally purchased, non-combustible Class Flat Roof Flashing 1 or Class 0 flexible duct. With Storm Collar 10KF Adjustable F

Summary of the content on the page No. 14

Gas Conversion Kits WARNING: THIS CONVERSION KIT SHALL BE IN- AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION STALLED BY A QUALIFIED SERVICE AGENCY IN AC- SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CORDANCE WITH THE MANUFACTURER'S INSTRUC- CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TIONS AND ALL APPLICABLE CODES AND REQUIRE- TOUTES EXIGENCES ET CODES APPLICABLES DE MENTS OF THE AUTHORIZED AGENCY HAVING JU- L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION RISDICTION. IF THE INFORMATION

Summary of the content on the page No. 15

Step 5. Millivolt Systems – Attach manom- When reinstalling the ignitor assembly, use eter to the manifold side pressure test fitting extreme care to prevent damage and break- and verify manifold pressure reads 3.5 inches age. Do not apply any leverage to the ignitor water column (0.87 kPa) for natural gas, and assembly while restoring the retainer clip to 10.0 inches water column (2.49 kPa) for pro- its original position. pane gas. All Models Step 6. See Figure 26 and remove the pilot Step

Summary of the content on the page No. 16

Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N 850,042M REV. A 12/2008 1110 West Taft Avenue • Orange, CA 92865 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16


Alternative user manuals
# User manual Category Download
1 Lennox Hearth 36" and 42" Wood Burning Fireplaces BR-36/42 User manual Indoor Fireplace 1
2 Lennox Hearth 36" and 42" Wood Burning Fireplaces BCI-36/42 User manual Indoor Fireplace 1
3 Lennox Hearth 36" and 42" Wood Burning Fireplaces BRI-36/42-2 User manual Indoor Fireplace 0
4 Lennox Hearth 36" and 42" Wood Burning Fireplaces BC-36/42 User manual Indoor Fireplace 2
5 Lennox Hearth 36" and 42" Wood Burning Fireplaces BRI-36/42 User manual Indoor Fireplace 3
6 Lennox Hearth 36" and 42" Wood Burning Fireplaces BC-36/42-2 User manual Indoor Fireplace 0
7 Lennox Hearth 36" and 42" Wood Burning Fireplaces BCI-36/42-2 User manual Indoor Fireplace 0
8 Lennox Hearth 36" and 42" Wood Burning Fireplaces BR-36/42-2 User manual Indoor Fireplace 0
9 Lennox Hearth 875027M User manual Indoor Fireplace 0
10 Lennox Hearth Adagio ADAGIO-EN User manual Indoor Fireplace 0
11 Lennox Hearth 4.5HTSK User manual Indoor Fireplace 0
12 Lennox Hearth Adagio ADAGIO-MP User manual Indoor Fireplace 0
13 Lennox Hearth Adagio ADAGIO-MN User manual Indoor Fireplace 0
14 Lennox Hearth ADAGIO-IG H5776 User manual Indoor Fireplace 0
15 Lennox Hearth ADK22CMBS User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1