Lopi Leyden Pellet user manual

User manual for the device Lopi Leyden Pellet

Device: Lopi Leyden Pellet
Category: Stove
Manufacturer: Lopi
Size: 2.35 MB
Added : 3/10/2014
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lopi Leyden Pellet. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lopi Leyden Pellet.

For your convenience

If looking through the Lopi Leyden Pellet user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lopi Leyden Pellet on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lopi Leyden Pellet to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lopi Leyden Pellet User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lopi Leyden Pellet but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lopi Leyden Pellet. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Leyden
Pellet Stove
• Horizontal Or Vertical Vent
• Freestanding Stove
• Mobile Home Approved
• Class A Chimney Retrofit
• Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
Tested and Listed by
Omni-Test Laboratories, Inc.
Beaverton, Oregon
Report # 028-S-77-2
ASTM E1509-2004
-- Please read this entire manual before installation and use of this pellet fuel-
burning room heater. Failure to follow these instructions could result in property
damage, bodily injury,

Summary of the content on the page No. 2

2 Introduction Introduction Congratulations! You have just purchased one of the finest hearth products on the market. Lopi heating appliances are solidly crafted and uniquely designed for the American lifestyle and proudly built in the U.S.A. Lopi wood, gas and pellet stoves, fireplaces and inserts have been America's Favorite Fire for over twenty- five years. Our reputation for solid craftsmanship, reliable performance and unbeatable heating efficiency has been a winning combination year after

Summary of the content on the page No. 3

Table of Contents 3 Introduction Operation (continued) Introduction......................................................2 Manual Mode.....................................................22 Important Information .........................................2 Auto Mode........................................................23 Restrictor Adjustment.........................................24 Safety Precautions Adjusting the Fan Speed......................................24 Safety Precautions ..........

Summary of the content on the page No. 4

Gas 4 Safety Precautions • Do not operate the • Contact your local building heater if you smell officials to obtain a permit smoke coming from and information on any the heater. Turn the installation restrictions or MODE switch to inspection requirements Ok "OFF", monitor your in your area. Notify your heater, and call your insurance company of this dealer. heater as well. • Never use gasoline, • The exhaust system must gasoline-type lantern fuel, be completely airtight and kerosene, charcoal

Summary of the content on the page No. 5

Safety Precautions 5 • The heater will not operate • This heater must be during a power outage. If connected to a standard a power outage does 115 V., 60 Hz grounded occur, check the heater electrical outlet. Do not for smoke spillage and use an adapter plug or open a window if any sever the grounding plug. smoke spills into the room. Do not route the electrical cord underneath, in front of, or over the heater. • Keep foreign objects out • When installed in a mobile ? of the hopper. home, the

Summary of the content on the page No. 6

6 Specifications Heating Specifications Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5 Maximum Burn Time on Low Burn** ......................................................................29 Hours Hopper Capacity ..............................................................................................50 Pou

Summary of the content on the page No. 7

Installation (For Qualified Installers Only) 7 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Check with local building officials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation. Packing List • Thermostat & Wire • Scraper Rod Tool • Brush • Spare Fuse • Bottle Brus

Summary of the content on the page No. 8

8 Installation (For Qualified Installers Only) Clearances - Straight Installation Through the Wall Installations Interior Vertical Vents AA A AA A AAAAAAAA 3” Minimum 2” AA A A AAAAAA A Minimum 3” Minimum “Tee” A AAAAAA A AAAAAAA A AAAAA A A AAAAAA A A AAAAA A A AAAAAA A A AAAAA A A AAAAAA A A AAAAA A A AAAAAA A 7” Minimum 7” Minimum A AAAAA A A AAAAAA A A AAAAA A A AAAAAA A Floor Protection 6” Minimum A AAAAA A A AAAAAA A 6” Minimum AAAAAAA AAAAAAAA Clearances - Corner Installation Through th

Summary of the content on the page No. 9

Installation (For Qualified Installers Only) 9 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. • USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH C

Summary of the content on the page No. 10

10 Installation (For Qualified Installers Only) Pellet Vent Type • Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc…) must be sealed with 500° F. RTV silicone. Installing the Pellet Vent Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap between sections. • Horizontal sections must

Summary of the content on the page No. 11

Installation (For Qualified Installers Only) 11 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the floor (Some states do not require this; check with your local building department). See the illustration to the right. • The heater must be grounded to the steel chassis of the mobile home (Some states do not require this; check with your local building department). WARNING: DO NOT INSTALL IN SLEEPING ROOM. CAUTIO

Summary of the content on the page No. 12

12 Installation (For Qualified Installers Only) Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met. • Minimum height is 55" • Maximum depth is 48" • Minimum width is 41-1/4" • Minimum clearance of 7" on each side and 3" on back Baffle Installation Install the baffles included with the stove (see page 31 for d

Summary of the content on the page No. 13

Installation (For Qualified Installers Only) 13 Thermostat Installation ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). A thermostat is included with this heater (part # 99300650). Follow the directions below to install. 1 Attach the thermostat wire to the circuit board Pull the cover off the thermostat (see the illustration below). Route the wire through the back of the heater (away from any

Summary of the content on the page No. 14

14 Installation (For Qualified Installers Only) Installation Example: Direct "Through-the-wall" Installation Horizontal Rain Cap Type "L" Vent 12” Minimum House Shield (used to protect exterior wall from soot A discoloration) is HIGHLY RECOMMENDED A A A A A Wall Thimble (note 3” clearance A A between vent and 3” Minimum Seal each vent combustibles) AAAAAAAA section (including adapters, elbows, A AAAAAA A etc...) by injecting a A AAAAAA A liberal amount of A AAAAAA A 500° F. RTV silico

Summary of the content on the page No. 15

Installation (For Qualified Installers Only) 15 Installation Example: Interior Vertical Installation 3” AAAAAAAA Minimum 2” A AAAAAA A Minimum “Tee” A AAAAAA A A AAAAAA A A AAAAAA A A AAAAAA A A AAAAAA A 7” Minimum Floor Protection A AAAAAA A A AAAAAA A A AAAAAA A 6” Minimum Vertical Cap A AAAAAA A AAAAAAAA 24” Minimum Storm Collar AAAAAAAAAAAAAAA AAAAAAAAAAAAAAA Roof Flashing AAAAAAAAAAAAAAA AAAA AAAAAAAAAAAAAAA A AA A Insulation must maintain AAAAAAAAAAAAAAA A AA A 3” clearance. AAAAAAAAA

Summary of the content on the page No. 16

16 Installation (For Qualified Installers Only) Installation Example: Class A Chimney Retrofit AAAAAAA 3” A AAAAA A Minimum 2” Minimum A AAAAA A “Tee” A AAAAA A A AAAAA A A AAAAA A A AAAAA A A AAAAA A 7” Minimum A AAAAA A A AAAAA A Floor Protection Seal each vent 6” Minimum A AAAAA A section (including adapters, elbows, AAAAAAA etc...) by injecting a liberal amount of AAAAA 500° F. RTV AAAAA AAAAAA silicone into the gap Class A Chimney between sections. AAAA A A Storm Collar A A A AAAA

Summary of the content on the page No. 17

Installation (For Qualified Installers Only) 17 Installation Example: Masonry Fireplace Hearth Stove Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. AAAAA AAAA Seal each vent AAAAAAAA AA AAAAA AAAAAAAAAA AAAA section (including AAAA AAAA AA A A AAAAA AAAA adapters, elbows, etc...) by injecting a A AA A AAAA AAAA AAAAAA AAAA A AA A liberal amount of A AA A AAAAAA AA A A AAAAAAA A AA A 500° F. RTV “L” Vent Flex silicone into the gap AAA

Summary of the content on the page No. 18

18 Installation (For Qualified Installers Only) Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove Vertical Cap Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. “L” Vent Seal each vent section (including AA adapters, elbows, AA etc...) by injecting a liberal amount of AAAA AA AAAA 500° F. RTV A AA A AA A AA A silicone into the gap between sections. A AA A AA A AA A AAAA AA AAAA AAAA AA “L” Vent Flex Section AAAA AA AAAA AA AAAA AAAAA AAAA

Summary of the content on the page No. 19

Installation (For Qualified Installers Only) 19 Installation Example: Freestanding Masonry Chimney Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. AAAAAAA AA AAAAAAA AA AAAAA AAA AA AAA AAA AAAA AAAA A A A AAAAA A A AAAAA AAAAA AAAA AAAAAA AAAAA AAA AAA AAAA AAAA Seal each vent section (including A AAA AAAAAAA A A A AAAAA A A AAAAAAAAA A AA A adapters, elbows, etc...) by injecting a AAAAA AAAA A A A AAAAA A A AAAAAAA A AA A liberal amount

Summary of the content on the page No. 20

20 Operation Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death. ! Do not unplug the stove to turn it off. This stove relies upon electricity to push the flue gases out the pellet vent – unplugging it may lead to smoke entering your room. ! Failure to maintain your heater will lead to a restricted combustion air system, leading to poo


Alternative user manuals
# User manual Category Download
1 Lopi ASTM E 1509-95 User manual Stove 0
2 Lopi CSA B366.2 User manual Stove 0
3 Lopi Direct Vent Freestanding User manual Stove 0
4 Lopi Answer Wood User manual Stove 0
5 Lopi Leyden 028-S-75-2 User manual Stove 0
6 Lopi Heritage DVL Direct Vent Large Gas User manual Stove 0
7 Lopi Endeavor User manual Stove 0
8 Lopi Horizontal Or Vertical Vent FreestandingYankee Pellet User manual Stove 0
9 Lopi Leyden Top Loading Cast Iron Wood User manual Stove 0
10 Lopi Leyden Wood User manual Stove 0
11 Lopi User manual Stove 0
12 Lopi Liberty Wood User manual Stove 0
13 Lopi UL 1482-94 User manual Stove 0
14 Lopi ULC S627-93 User manual Stove 0
15 Lopi Yankee PS User manual Stove 0
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3