United States Stove PELLET 5660(I) user manual

User manual for the device United States Stove PELLET 5660(I)

Device: United States Stove PELLET 5660(I)
Category: Stove
Manufacturer: United States Stove
Size: 2.46 MB
Added : 8/9/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for United States Stove PELLET 5660(I). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with United States Stove PELLET 5660(I).

For your convenience

If looking through the United States Stove PELLET 5660(I) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual United States Stove PELLET 5660(I) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual United States Stove PELLET 5660(I) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
United States Stove PELLET 5660(I) User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual United States Stove PELLET 5660(I) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to United States Stove PELLET 5660(I). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation and Operating Manual 
Models 5660(I) 
 
Tested & 
 
Listed By 
 
 
Report #: 
215‐S‐32‐4and215‐S‐33‐4
Safety Notice 
Please read this entire manual before installation and use of this pellet fuel‐burning room heater. Failure to follow 
instructions may result in property damage, bodily injury, or even death. 
 
If your heater is not properly installed, a house fire may result. For everyone’s safety, FOLLOW all Installation and 
Operating Directions. Never use makeshift compromises d

Summary of the content on the page No. 2

TABLE OF CONTENTS  Topic            Page(s)    Introduction            3  Safety Information                   4‐5  Specifications             6  Dimensions                    6‐7  Operating Instructions                          8‐11  Thermostat Installation                   12  Clearances to Combustibles                        13  Installing Your Room Heater          14‐23  Mobile Home Installations                  24  Insert Pellet Stove  Installation          25‐28  Vent Termination Locatio

Summary of the content on the page No. 3

Introduction    The entire family of United States Stove Company thanks you for purchasing your new pellet burning room heater.   At U.S. Stove, we build all of our products with a hands‐on approach to detail and quality.  Our old world team of  Craftsmen take great pride in their superior workmanship to ensure you have years of trouble free use of your  pellet heater.     U.S. Stove Pellet Burning Room Heaters have been tested and listed for installation in residential, mobile home  and alcove 

Summary of the content on the page No. 4

SAFETY INFORMATION    Be sure to read the entire owner’s manual prior to installing and operating this Pellet heater.  Failure to follow  these instructions could result in fire, property damage, bodily injury or even Death.  This stove’s exhaust system works with negative combustion chamber pressure and a slight positive chimney  pressure, it is extremely important to ensure that the exhaust system be sealed and airtight. The ash pan and  viewing door must be securely fastened in order for the 

Summary of the content on the page No. 5

SAFETY INFORMATION ‐ continued    Keep foreign objects out of the hopper.  Contact  your  local  building  officials  to  obtain  a  permit  and  information  on  any  installation  restrictions  or  inspection requirements in your area.   Be sure to notify your insurance company of your new U.S. Stove Pellet Burning Room Heater.  Allow the Pellet Stove Room Heater to cool before performing any maintenance.  Ashes must be disposed of in a metal container with a tight lid and placed on a noncombu

Summary of the content on the page No. 6

SPECIFICATIONS    Heating Specifications:    Burn Rate:       *43,900 btu’s per hour or 5.1 lbs. of fuel per hour  Hopper Capacity:       55 lbs.    *Dependent upon quality and heating value of pellet fuel.    DIMENSIONS    Figure 1  6 

Summary of the content on the page No. 7

DIMENSIONS ‐ continued  The minimum installation dimensions, of the insert opening, are:    32” (813mm) wide x 22‐3/4” (578mm) high x 12‐1/4” (311mm) deep.    Figure 2            7 

Summary of the content on the page No. 8

OPERATING INSTRUCTIONS  Check and Fill the Fuel Hopper with Pellets:  This Pellet Stove is available as a freestanding unit or as a fireplace insert.  There is a different method for filling  the hopper for each type of heater:   To check and fill the hopper of the freestanding heater, simply lift the hopper door, visually check the hopper  and add pellets when needed.     To check and fill the hopper of the insert heater, pull hopper lid forward, visually check the hopper and add  pellets whe

Summary of the content on the page No. 9

    OPERATING INSTRUCTIONS ‐ continued    When the pellets have ignited and flame has been established, the start‐up cycle will end; this procedure takes  between 8 and 12 minutes.  If the control is set to Manual Mode, it will now default to the heat level setting the  last shutdown time.  If the control is set to T‐STAT Mode the heat output will coincide to the commands from the  thermostat.    Auger:   As explained in the starting up step, this button is only served to start up the pellet sto

Summary of the content on the page No. 10

OPERATING INSTRUCTIONS ‐ continued    Control Board Functions:     MODE Button: The MODE button allows you to switch operating mode on  your Pellet Stove Room Heater.  Depress the MODE button to switch between  Manual and T‐STAT modes.  As you depress the MODE button the indicator  light above the desired mode will engage.  When you engage the Manual mode,  you will be able to manually select the heat settings.  If you have installed a  remote thermostat for your Pellet Stove Room Heater and wis

Summary of the content on the page No. 11

OPERATING INSTRUCTIONS ‐ continued    the Auger feed rate will help keep the flames from extinguishing on the minimum heat level setting.  You can also  use the AUGER TRIM button to lower heat output on the minimum heat level setting:   Depress and release the AUGER TRIM button until the heat level 1 and 5 setting lights appear to slightly  increase the feed rate on the minimum heat level.   Depress and release the AUGER TRIM button until the heat level 1 and 4 setting lights appear to slightl

Summary of the content on the page No. 12

    THERMOSTAT INSTALLATION    Optional thermostats are available for use with your pellet stove. A thermostat can help you maintain a constant  room temperature. The thermostat option will require the installation of a millivolt type thermostat.    NOTE: Your thermostat should be installed by an authorized dealer or service person.    Installation of Remote Thermostat:   Disconnect Pellet Stove Room Heater unit from power supply.   Open right side panel to gain access to rear of control panel

Summary of the content on the page No. 13

CLEARANCES TO COMBUSTIBLES  INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER!    When your Pellet Stove Room Heater is being installed on a combustible floor it is mandatory that a 1/2"  (13mm) thick non‐combustible hearth pad be installed under the heater. The non‐combustible hearth  pad must extend at least 6” beyond the fuel loading and ash removal openings and at least the depth of  the heater plus 6 inches (152mm) out in front of the heater.  This applies to both freestand

Summary of the content on the page No. 14

  INSTALLING YOUR ROOM HEATER      You have already made the important decision of choosing your U.S. Stove Pellet Burning Room Heater;  now your next step is to determine where to install your new pellet stove heater. To get the most  efficient use of re‐circulated heat, you should consider a room that is centrally located within your home.   Choose a room that is large and open.    It is Extremely Important to maintain proper clearances from any combustible surfaces or materials in  the room w

Summary of the content on the page No. 15

INSTALLING YOUR ROOM HEATER ‐ continued    HORIZONTAL EXHAUST VENT INSTALLATION    1. Locate your pellet stove in a location which meets the requirements of this manual, but in an area  where it does not interfere with the house framing, wiring, etc.  2. Install a non‐combustible hearth pad underneath the pellet stove. This pad should extend at least 6”  (152mm) in front of the unit.  3. Place the pellet stove approximately 15” (381mm) away from the interior wall.  4. Locate the center of the ex

Summary of the content on the page No. 16

INSTALLING YOUR ROOM HEATER ‐ continued  HORIZONTAL EXHAUST VENT INSTALLATION      16 

Summary of the content on the page No. 17

 INSTALLING YOUR ROOM HEATER ‐ continued  FREESTANDING INTERIOR VERTICAL INSTALLATION    1. Locate your Pellet Stove Room Heater in a location which meets the requirements of this manual, but  in an area where it does not interfere with the house framing, wiring, etc.  2. Install a non‐combustible hearth pad underneath the pellet stove. This pad should extend at least 6”  (152mm) in front of the unit.  3. Place your Pellet Stove Room Heater on the hearth pad and locate the unit in manner that wi

Summary of the content on the page No. 18

INSTALLING YOUR ROOM HEATER ‐ continued  FREESTANDING EXTERIOR VERTICAL INSTALLATION    1. Locate your Pellet Stove Room Heater in a location which meets the requirements of this manual, but  in an area where it does not interfere with the house framing, wiring, etc.  2. Install a non‐combustible hearth pad underneath the pellet stove. This pad should extend at least 6”  (152mm) in front of the unit.  3. Place your Pellet Stove Room Heater on the hearth pad and locate the unit in manner that wil

Summary of the content on the page No. 19

  19 

Summary of the content on the page No. 20

INSTALLING YOUR ROOM HEATER ‐ continued  SELKIRK DIRECT‐TEMP VENT SYSTEM FOR PELLET STOVE HEATERS  Images courtesy of Selkirk  20 


Alternative user manuals
# User manual Category Download
1 United States Stove 2000 User manual Stove 1
2 United States Stove 5500/5500XL User manual Stove 1
3 United States Stove 2500 User manual Stove 0
4 United States Stove 5500XL User manual Stove 0
5 United States Stove 5500 User manual Stove 0
6 United States Stove 58242 User manual Stove 0
7 United States Stove 5700 User manual Stove 0
8 United States Stove 5510 User manual Stove 12
9 United States Stove 5500M User manual Stove 0
10 United States Stove 6035 User manual Stove 1
11 United States Stove 6039 User manual Stove 4
12 United States Stove 6039I User manual Stove 0
13 United States Stove 6039HF User manual Stove 2
14 United States Stove 6039T User manual Stove 0
15 United States Stove C9947L User manual Stove 1
16 Edelbrock 2006-2007 (N) User manual Stove 4
17 Aarrow Fires SF 50 User manual Stove 1
18 Aarrow Fires EcoBurn BK043 User manual Stove 0
19 Aarrow Fires EcoBurn AFS1221 User manual Stove 0
20 Aga Ranges Berrington User manual Stove 3