Briggs & Stratton 030319 user manual

User manual for the device Briggs & Stratton 030319

Device: Briggs & Stratton 030319
Category: Portable Generator
Manufacturer: Briggs & Stratton
Size: 2.99 MB
Added : 6/16/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Briggs & Stratton 030319. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Briggs & Stratton 030319.

For your convenience

If looking through the Briggs & Stratton 030319 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Briggs & Stratton 030319 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Briggs & Stratton 030319 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Briggs & Stratton 030319 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Briggs & Stratton 030319 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Briggs & Stratton 030319. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operator’s Manual
Manual del Operario
Models / Modelos
4000 WATT
030319
5000 STARTING WATTS
030320
Questions? Help is just a moment away!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline
Llame: Línea Directa del Generador
1-800-743-4115 M-F 8-5 CT
web: www.briggsandstratton.com
WARNING ADVERTENCIA
Before using this product, read this manual and follow all Antes de utilizar el producto, lea este manual y siga todas las
Safety Rules and Operating Instructions. Reglas de

Summary of the content on the page No. 2

SAFETY RULES SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAFETY RULES Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 This is the safety alert symbol. It is used to Features and Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 alert you to potential personal injury hazards. Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Obey all safety messages that follow this Operation . . . . . . . . . . . . . .

Summary of the content on the page No. 3

SAFETY RULES WARNING WARNING Running generator gives off carbon monoxide, Fuel and its vapors are extremely flammable and an odorless, colorless, poison gas. explosive. Breathing carbon monoxide can cause nausea, Fire or explosion can cause severe burns or fainting or death. death. � Operate generator ONLY outdoors. WHEN ADDING OR DRAINING FUEL � Keep exhaust gas from entering a confined area through � Turn generator OFF and let it cool at least 2 minutes before windows, doors, ventilation intak

Summary of the content on the page No. 4

SAFETY RULES WARNING CAUTION Excessively high operating speeds increase risk of injury and damage to generator. Unintentional sparking can result in fire or Excessively low speeds impose a heavy load. electric shock. � DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed WHEN ADJUSTING OR MAKING REPAIRS TO YOUR speed. GENERATOR � DO NOT modify generator in any way. � Disconnect the spark plug wire from the spark plug and place the wir

Summary of the content on the page No. 5

FEATURES AND CONTROLS KNOW YOUR GENERATOR Read this operator’s manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Spark Arrester Muffler Fuel Valve Fuel Tank 120 Volt AC, 20 Amp On/Off Switch Duplex Receptacles Circuit Breakers (AC) Data Tag Grounding Fastener Oil Fill Cap/Dipstick Choke Lever Air Cleaner Oil Drain Plug Recoil

Summary of the content on the page No. 6

ASSEMBLY � 9/16” wrench ASSEMBLY � Pliers Your generator requires some assembly and is ready for � Safety glasses use after it has been properly serviced with the Refer to Figure 1 and install the wheel kit as follows: recommended oil and fuel. 1. Tip generator so that engine end is up. If you have any problems with the assembly of your 2. Slide axle through both mounting brackets. generator, please call the generator helpline at 1-800-743-4115. If calling for assistance, please have the 3. Plac

Summary of the content on the page No. 7

ASSEMBLY 10. Return generator to normal operating position (resting Type of Fuel on wheels and support leg). 1. Always use clean, fresh, UNLEADED gasoline with a 11. Attach handle using a long (M8 x 45mm) cap screw minimum of 87 octane/87 AKI (91 RON). DO NOT and lock washer.Tighten with a 9/16” wrench. mix oil with fuel. DO NOT modify the engine fuel system or carburetor to run on alternative fuels. BEFORE STARTING THE NOTE: Fuel with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertia

Summary of the content on the page No. 8

OPERATION Generator Location USING THE GENERATOR Generator Clearance System Ground WARNING The generator has a system ground that connects the Exhaust heat/gases can ignite combustibles, generator frame components to the ground terminals on structures or damage fuel tank causing a fire. the AC output receptacles.The system ground is connected � Keep at least 5 ft. (152 cm) clearance on all sides of generator to the AC neutral wire (see “Equipment Description”, including overhead. earlier in this

Summary of the content on the page No. 9

OPERATION OPERATING THE WARNING Rapid retraction of starter cord (kickback) will GENERATOR pull hand and arm toward engine faster than you can let go. Starting the Engine Broken bones, fractures, bruises or sprains could result. Disconnect all electrical loads from the generator. Use the � When starting engine, pull cord slowly until resistance is felt following start instructions: and then pull rapidly to avoid kickback. 1. Make sure unit is on a level surface. � NEVER start or stop engine with

Summary of the content on the page No. 10

OPERATION Connecting Electrical Loads RECEPTACLES � Let engine stabilize and warm up for a few minutes after CAUTION starting. Receptacles may be marked with rating value greater � Plug in and turn on the desired 120 Volt AC, single phase, than generator output capacity. 60 Hz electrical loads. � NEVER attempt to power a device requiring more amperage � DO NOT connect 240 Volt loads to the 120 Volt duplex than generator or receptacle can supply. receptacles. � DO NOT overload the generator. See

Summary of the content on the page No. 11

OPERATION 4. Plug in and turn on the next load. DON'T OVERLOAD 5. Again, permit the generator to stabilize. GENERATOR 6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, Capacity as described above. You must make sure your generator can supply enough Figure 8 - Wattage Reference Chart rated (running) and surge (starting) watts for the items you Additional will power at the same time.

Summary of the content on the page No. 12

SPECIFICATIONS ENGINE TECHNICAL PRODUCT INFORMATION SPECIFICATIONS This is a single cylinder, overhead valve(OHV), air cooled Generator Specifications engine. It is a low emissions engine. Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . .5,000 Watts In the State of California, Model Series 120000 engines are Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,000 Watts certified by the California Air Resources Board to meet emissions standards for 125 hours. Such

Summary of the content on the page No. 13

MAINTENANCE environment where it will not be exposed to excessive GENERAL dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, RECOMMENDATIONS leaves, or any other foreign material. Regular maintenance will improve the performance and Check the cleanliness of the generator frequently and clean extend the life of the generator. See any authorized dealer when dust, dirt, oil, moisture or other foreign substances for service. are visibl

Summary of the content on the page No. 14

MAINTENANCE � Use low pressure air (not to exceed 25 psi) to blow NOTE: Synthetic oil meeting ILSAC GF-2,API certification away dirt. Inspect cooling air slots and openings on the mark and API service symbol with “SJ/CF ENERGY generator.These openings must be kept clean and CONSERVING” or higher, is an acceptable oil at all unobstructed. temperatures. Use of synthetic oil does not alter required oil change intervals. CAUTION SAE 30: 40 °F and higher (5 °C and higher) is good for all Improper tre

Summary of the content on the page No. 15

MAINTENANCE To service the air cleaner, follow these steps: 3. Clean area around oil drain plug.The oil drain plug is located at base of engine, opposite carburetor. 1. Loosen screw and tilt cover down (Figure 10). 4. Remove oil drain plug and drain oil completely into a Figure 10 - Air Cleaner suitable container. 5. Reinstall oil drain plug and tighten securely. Remove oil cap/dipstick. 6. Slowly pour recommended oil (about 20 oz.) into oil fill opening. Pause to permit oil to settle. Fill to “

Summary of the content on the page No. 16

MAINTENANCE Clean Cooling System WARNING Over time debris may accumulate in cylinder cooling fins Running engines produce heat.Temperature of and cannot be observed without partial engine disassembly. muffler and nearby areas can reach or exceed For this reason, we recommend you have a authorized 150°F (65°C). service dealer clean the cooling system (Figure 13) per Severe burns can occur on contact. recommended intervals (see “Maintenance Schedule” on Exhaust heat/gases can ignite combustibles,

Summary of the content on the page No. 17

STORAGE � Run engine outdoors for several minutes to be sure STORAGE treated fuel has replaced untreated fuel in carburetor. The generator should be started at least once every seven If fuel preserver is not used, then always remove all fuel from tank and run engine until it stops from lack of fuel. days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use Change Oil the following information as a guide to prepare it for storage. W

Summary of the content on the page No. 18

TROUBLESHOOTING TROUBLESHOOTING Problem Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord set. 3. Check and repair. AC output is available. 4. Connected device is bad. 4. Connect another device that is in good condition. 1. Short circuit in a connected load. 1. Disconnect shorted electrical load. Engine runs good at no- 2. Engine speed is

Summary of the content on the page No. 19

NOTES NOTES 19

Summary of the content on the page No. 20

EMISSIONS CONTROL SYSTEM WARRANTY Briggs & Stratton Corporation (B&S), the California Air Resources Board (CARB) and the United States Environmental Protection Agency (U.S. EPA) Emissions Control System Warranty Statement (Owner’s Defect Warranty Rights and Obligations) California, United States and Canada Emissions Control a. Fuel Metering System Defects Warranty Statement � Cold start enrichment system (soft choke) The California Air Resources Board (CARB), U.S. EPA and B&S are � Carburetor an


Alternative user manuals
# User manual Category Download
1 Briggs & Stratton 01892 User manual Portable Generator 48
2 Briggs & Stratton 01654 User manual Portable Generator 18
3 Briggs & Stratton 01917-0, 01918-0 User manual Portable Generator 21
4 Briggs & Stratton 01933 User manual Portable Generator 11
5 Briggs & Stratton 01653 User manual Portable Generator 16
6 Briggs & Stratton 01932 User manual Portable Generator 11
7 Briggs & Stratton 01815-0 User manual Portable Generator 1
8 Briggs & Stratton 01938-0 User manual Portable Generator 4
9 Briggs & Stratton 030213 User manual Portable Generator 5
10 Briggs & Stratton 030207 User manual Portable Generator 82
11 Briggs & Stratton 030231 User manual Portable Generator 0
12 Briggs & Stratton 030209-2 User manual Portable Generator 12
13 Briggs & Stratton 030208-2 User manual Portable Generator 1
14 Briggs & Stratton 030235-01 User manual Portable Generator 10
15 Briggs & Stratton 01971 User manual Portable Generator 68
16 ACDelco AC-G0005 User manual Portable Generator 1
17 ACDelco AC-G0002 User manual Portable Generator 0
18 ACDelco AC-G0004 User manual Portable Generator 3
19 AEG 2.33 2 User manual Portable Generator 3