Summary of the content on the page No. 1
7,500 Watt Peak, 6,600
Watt Rated GeNeRat OR
®
WItH ROBIN eNGINe
91377
aSSeMBLY aNd OPeRatING INStRUCtIONS
Distributed exclusively by Harbor Freight Tools.
3491 Mission oaks BlvD., CaMarillo, Ca 93011
VISIt OUR WeB SIte at HttP://WWW .HaRBORfReIGHt.COM
tO HeLP PReVeNt SeRIOUS INjURY OR deatH,
Read aNd UNdeRStaNd aLL WaRNINGS
aNd INStRUCtIONS BefORe USe.
®
Copyright © 2004 by Harbor Freight Tools . all rights reserved. n o portion of this manual
or any artwork contained herein may be reprodu
Summary of the content on the page No. 2
SPeCIfICatIONS Generator Wattage @ 240v: 6,600 (rated), 7,500 (peak) Wattage @ 125v: 6,000 (rated), alternator: single phase, 6 kva. v oltage: 240 / 125 vaC, 60Hz; nominal current: 50 amps at 125 vaC, 25 amps at 240 vaC; outlets: 120 vaC standard, 120 vaC twist-lock 3-prong (l530), 240/120 vaC twist-lock (l430) Triple circuit breaker system, resettable ® Engine 13.5 HP robin subaru : EH41 with heavy cast iron sleeve. EPa and Carb. approved; Four cycle engine, 7.0 gallon gas tank, 404-cc d
Summary of the content on the page No. 3
Read all instructions before installing or using this generator! 1. Ensure installation meets all applicable safety, and local and national electrical codes. Have installation performed by a qualified, licensed electrician and building contractor. 2. Do not operate the generator with protective covers, access covers, or terminal box covers removed. 3. Disable engine-starting circuits before carrying out maintenance. 4. Disable closing circuits and place warning notices on any circuit breakers
Summary of the content on the page No. 4
Handling and Installation Precautions 1. all electrical work, including earth-ground connection, should be completed by a licensed electrician. 2. any separate fuel storage generator supply facility, must be built or installed in full compliance with relevant local, state, and federal regulations. 3. if the generator is installed indoors, exhaust fumes must be piped out of the building using leak-free, heat-resistant piping. Pipes and silencer should not use any flammable materials, nor shou
Summary of the content on the page No. 5
8. Do not refill the generator fuel tank of the bed frame while the engine is running. 9. Do not operate the generator with known leaks in the fuel system. 10. Use only engine manufacturer recommended fuel and oil fluids. Mechanical Precautions 1. The generator is designed with guards for protection from moving parts. in any case, care must still be taken to protect personnel and equipment from other mechanical hazards when working around the generator. 2. Do not operate the generator with saf
Summary of the content on the page No. 6
8. keep all electrical equipment clean and dry. replace any wiring where the insulation is cracked, cut, abraded or otherwise degraded. replace terminals that are worn, discolored, or corroded. keep terminals clean and tight. 9. insulate all connections and disconnected wires. 10. Use only Class BC or Class ABC fire extinguishers on electrical fires. eLeCt RIC GeNeRat OR Safet Y PReCa Ut IONS a Nd Wa RNINGS 1. Carbon Monoxide Inhalation Hazard this engine-run generator must never be used indoo
Summary of the content on the page No. 7
12. only use 3-prong (125 vaC) or 4-prong (240 vaC), grounded extension cords. Warning: t he warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. fIRSt aId fOR eLeCtRIC SHOCk 1. Do not touch the victim’s skin with bare hands until the source of the
Summary of the content on the page No. 8
should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock. (see Figure a.) 2. The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (see Figure a.) 3. Your tool must
Summary of the content on the page No. 9
6. If you are using an extension cord outdoors, make sure it is marked with the suffix “W- a” (“W” in Canada) to indicate it is acceptable for outdoor use. 7. Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas. ReCOMMeNded MINIMUM WIRe GaUGe fOR exteNSION CORdS* (120/240
Summary of the content on the page No. 10
UNPaCkING When unpacking, check to make sure that all the parts are included. refer to the assembly section, and the assembly Drawing and Parts list at the end of this manual. if any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual as soon as possible. OPeRatING INStRUCtIONS Generator engine Controls Gas valve Engine on/off switch Choke starter Pull Cord Generator electrical Controls and Outlets 30a Circuit Breaker reset Button 30a Circu
Summary of the content on the page No. 11
Generator Setup and Cable Connections 1. Place the Generator outdoors where it will be used. This should be on a flat surface and away from flammable materials. Do not allow the Generator to get wet. if used indoors, the area must be well ventilated to allow dissipation of exhaust fumes. 2. Fill the Gas Tank (outdoors) with up to seven gallons of unleaded gasoline. Do not top-off tank. 3. add 40 oz. of oil to the Engine by removing either Dip stick, and adding through its hole. if the a
Summary of the content on the page No. 12
® The Engine should start. Try again if it does not start. refer to the robin subaru operator’s Manual under Troubleshooting if problems persist. let the engine run for five minutes to warm up. 7. Push in the Choke Button. 8. Begin to turn on the connected appliances. The Engine governor will regulate the throttle automatically depending on the electrical load applied to the generator. if electricity to one of the outlets stops, it could be that the circuit was overloaded. Check the applian
Summary of the content on the page No. 13
PaRtS LISt Part Code # description qty. 1 EH410GE Ga EnGinE, 13.5 HP, roBin 1 2 31227 sinGlE PHasE al TErna Tor, 6 kva 1 3 30010102 MoUnTinG FlanGE 1 5 30060802 EnD CovEr 1 6 15051079 TUBE FraME 1 7 30050202 FUEl Tank, 7 Gal 1 10 15190240 ConTrol PanEl 1 11 45040103 ConT aCT BoX 1 12 15170101 HEaT sHiElD 1 13 30070102 FUEl CaP 1 14 15050104 BraCkET 1 15 15050101 BraCkET 2 16 10160102 rUBBEr sUPPor T 3 17 70130202 5/16”, BiG BUMPErs 4 18 60130703 1/4” X 1” HEX HEaD TaPPinG sCrEW 6 19 60020206 5/1
Summary of the content on the page No. 14
aSSeMBLY dRa WING PLeaSe Read tHe fOLLOWING CaRefULLY tHe MaNUfaCtUReR aNd/OR dIStRIBUt OR HaS PROVIded tHe P aRtS dIaGRaM IN tHIS MaNUaL aS a RefeReNCe t OOL ONLY. NeItHeR tHe MaNUfaCtUReR NOR dIStRIBUt OR MakeS aNY RePReSeNtatION OR W aRRaNtY Of aNY kINd t O tHe BUYeR tHat He OR SHe IS qUaLIfIed t O Make a NY RePa IRS t O t He PROdUCt OR t Hat He OR SHe IS q Ua LIf Ied t O RePLa Ce a NY Pa Rt S Of tHe PROdUCt . IN faCt , tHe MaNUfaCtUReR aNd/OR dIStRIBUt OR exPReSSLY StateS tHat a LL R
Summary of the content on the page No. 15
WIRING dIaGRaM Note: Only a licensed electrician should perform electrical repairs on this generator. Black Black White Green skU 91377 for technical questions, please call 1-800-444-3353. Page 15
Summary of the content on the page No. 16
SCHeMatIC dRa WING Re-StaRteR SWItCH WItH GfCI E D D 5 4 7 6 9 3 F 1 B 2 a B 12 11 C G 10 PaRtS LISt IteM qtY deSCRIPtION aSSeMBLY Of CaBLe & teRMINaLS a 1 inlet 20a B 1 inlet 30a 125/250v Blue C 1 inlet 30a 129 D 2 re-starter 20a red E 1 re-starter 25a 125/250v Black F 1 Wiring Harness White G 1 Wiring Type Black 125 Cable of Caliber 12 White Black 200 Cable of Caliber 12 Black Black 105 Cable of Caliber 12 Green 65 Cable of Caliber 12 red Black 55 Cable of Caliber 12 Blue