GSM REMOTE SUPERVISION 
 
  
   
GB 051 Set for cellular phone Siemens C35i, M35 or S35 
Automatic Information Transfer over the GSM Network 
 
  
 
 
 
 
 
 
 
 
 
 
USER GUIDE 
 
 
 
LEVEL 
 
                                                                                                                                                                                                                                                                                                            
                    
                    Summary of the content on the page No. 2 
                    
                          Dear Customers,     We would like to congratulate you on purchasing our product – GSM Remote Supervision  GB 051. This way you are getting a high-class and technically highly modern product.    GSM Remote Supervision GB 051 allows first-class and highly effective protection of cars  or properties. It provides protection which cannot be easily disabled by cutting the phone  line, protection which sends an ALARM message within 3 seconds and which allows also  continuous control of protected area
                    
                    Summary of the content on the page No. 3 
                    
                        TABLE OF CONTENTS – GSM Remote Supervision GB 051    1. Product Description................................ ................................ ........................ 4  1.2. Contents of Delivery ................................ ................................ ............... 5  2. Safety Commands ................................ ................................ ......................... 5  3. Installation and Setting into Operation................................ ............................ 6 
                    
                    Summary of the content on the page No. 4 
                    
                        1. Product Description    1.1. Description of Function    GSM Remote Supervision GB 051 consists of plastic box, which is firmly joined to  the battery of cell phone. Communication cable with connector gets out of this box  into cell phone, which is used by GB 051 for realization of phone connection and  reception and sending of SMS messages.    On the upper side of the box there is a cut-off terminal board with terminals for  power supply, for interface to PC, control inputs and 8 input/output 
                    
                    Summary of the content on the page No. 5 
                    
                        1.2. Contents of Delivery      Sets  Label  Component description   GB 051 010 GSM Remote Control only ● ●    GB 051 011 GSM Remote Control with the Siemens C35i mobile phone   ● ●  SA 012 602 AC/DC Adapter 220 V / 12 V DC, 600 mA, cable 1,5 m long  ●  ●   Connector ● ● ● ●  13 004 027 Siemens C35i mobile phone only ○ ○    External FME antenna reduction cable for the  13 004 028 ○ ○ ○ ○  Siemens C35i mobile phone  ED 001 001 External 3 dB antenna with magnet, 3 meter cable ○ ○ ○ ○  ED 001 002 Fl
                    
                    Summary of the content on the page No. 6 
                    
                        The GB 051 unit must be stocked always with the mobile phone connector  disconnected – when disconnected from external power supply, the GB 051 is  supplied from the mobile phone battery and the battery can be damaged by getting  !  completely flat.      3. Installation and Setting into Operation    3.1. Assembly of GSM Remote Supervision    GSM Remote Supervision by LEVEL is designed for operation in dry places.  During assembly avoid hot places and places where device would be exposed to  dire
                    
                    Summary of the content on the page No. 7 
                    
                        RESET By connection clips no. 2 and 3 (ground and reset) the unit reset will  be run, while all the set configuration value will remain in place.   The value of days in service will be set to 0.  INIT Detailed description of how to carry on the initialization can be found  in Chapter 4.1. The GSM Remote Control device will be set into  default manufacturer’s settings by the initialization.              Recommended linkage of outputs: Recommended linkage of inputs:          If GSM signal is insuf
                    
                    Summary of the content on the page No. 8 
                    
                          Cell phone must be in basic configuration, only parameters specified further can  be changed.     A SIM card inserted in the GB 051 device must be configured in one of the two  ways described below:  a) If SIM is not blocked by PIN code, then the PIN value in GB 051 is irrelevant –  in this case you can skip this instruction and continue to  assembly the GB 051 and the cell phone.  b) If SIM is blocked by PIN, and then the PIN in GB 051 must be the same with  the PIN at the SIM in mobile phone
                    
                    Summary of the content on the page No. 9 
                    
                        If the PIN code on the SIM card is the same as the PIN in GB 051 and SIM is  blocked by PIN, then after setting new PIN to the GB 051 unit the PIN will be  changed in both – the SIM and GB 051 unit.    GB 051 replies to this SMS message and draws sender’s attention to necessity of  unification of PIN in Remote Supervision and phone and to necessity of switch-off  of cell phone.    After reception of this SMS message verify correct PIN code change by switching  the phone off with the red phone bu
                    
                    Summary of the content on the page No. 10 
                    
                         Send a control SMS message from cell phone or Internet, which includes in text:    XXppppINSTRUCTIONVparameter    XX  Two capital letters X  pppp Four digits of current PIN in GSM Remote Supervision  INSTRUCTION Key word of the command (no difference with capital or small  letters)  V Space follows  parameter Set-up value*  End of sequence by space or end of SMS message    One SMS can include up to 4 commands. The message then can look like this:  XXppppCOMMAND1Vparameter1VCOMMAND2Vparameter2VC
                    
                    Summary of the content on the page No. 11 
                    
                        Value of PIN of GSM gate set from production and after initialization is 0000. PIN  0000 shall not be set into cell phone from gate so that blockage of phone is not  caused during first contacts with gate.      Example:  Original PIN of GSM gate is 0000. SIM card, which you use in cell phone in GSM  gate has PIN 1234 and is blocked by PIN.    Insert the SIM card into the mobile phone, but do not connect the GB 051  connector yet. Insert the required PIN in the mobile phone (e.g. 1234). Go into t
                    
                    Summary of the content on the page No. 12 
                    
                        4.3. INIT – Re-initialization of Values Set from Production    In case you lost view of GB 051 set-up you can carry out remote re-initialization of  parameter values set in production.     Command XXppppINIT  Pppp Four digits of current PIN      GSM Remote Supervision will be set to initial set-up from production.    Sender of Command receives message about correct reception of Command.    In case you do not know pre-set PIN or you are not able to program for another  reason then carry out hardw
                    
                    Summary of the content on the page No. 13 
                    
                        *1) Command XXppppMCALLVnumber   Pppp Four digits of current PIN  *2) Number Maximum 14 digits of number of any phone     *1) The space is between key word of command „MCALL“ and value of parameter „h“    *2) Number can be entered in national format – e.g. 606445566 but also in international    format – e.g. +420606445566. No number is activated from production.    After entering this parameter GB 051 calls set number once a month in order to  spend at least one tariff impulse.    If you want to
                    
                    Summary of the content on the page No. 14 
                    
                        If you want to deactivate this function set command without parameter – tm.  XXppppINFOSMS without further parameters.    4.8. SMSINT – Interval for Dispatch of SMS Messages about Operation     Interval for sending regular SMS messages to INFOSMS number, which include  time of operation, can be set:     Command XXppppSMSINTVn (interval of one day is set from production)  *1)   pppp Four digits of current PIN  Number Number from 1 to 30. It is interval for sending successive  message about operat
                    
                    Summary of the content on the page No. 15 
                    
                        Activated by input Order on the  *1) Command    No.: terminal board  XXppppSMSNOA1Vnumber IO1 1  XXppppSMSNOB1Vnumber IO1 1  XXppppSMSNOA2Vnumber IO2 2  XXppppSMSNOB2Vnumber IO2 2  XXppppSMSNOA3Vnumber IO3 3  XXppppSMSNOB3Vnumber IO3 3  XXppppSMSNOA4Vnumber IO4 4  XXppppSMSNOB4Vnumber IO4 4  XXppppSMSNOA5Vnumber IO5 5  XXppppSMSNOB5Vnumber  IO5 5  XXppppSMSNOA6Vnumber IO6 6  XXppppSMSNOB6Vnumber IO6 6  XXppppSMSNOB7Vnumber IO7 8  XXppppSMSNOB7Vnumber IO7 8  XXppppSMSNOB8Vnumber IO8 9  XXppppSMSN
                    
                    Summary of the content on the page No. 16 
                    
                        If you only want to change value of output regardless of previous state send  command without parameter “y” – e.g. XXppppOUT5 changes value of output No.  5 to reverse.    Newly set actual values of all 8 inputs/outputs are sent back to sender and to  INFOSMS number.      4.11. LIST – Detection of Set-up    If you want to find out which values of parameters are set in GB 051 it is possible  to send control SMS message, which initiates sending messages with detailed  description of set-up back to
                    
                    Summary of the content on the page No. 17 
                    
                          The call will take 255 seconds unless you end it sooner by hang-up.        Sensitivity of cell phone built-in microphone might be relatively low. Therefore it is  necessary to select a suitable placement of the unit in order to use this feature.   5. Programming from PC    Comfortable way of setting of all GB 051 parameters from PC by the means of  configuration program and serial cable with converter can be used. Program and cable  can be bought additionally as set for configuration from PC –
                    
                    Summary of the content on the page No. 18 
                    
                          7. List of Programming Commands – Control SMS Messages    Command XXpppp  Description Range Set  *1)   Set PIN  PINVnnnn nnnn 4 digits of PIN 0000  RESET of GSM Supervision RESET – –  Initialisation of parameters INIT – –  Regular information calling ICALLVn n= max. 14 digits –  Length of interval of calling ICALLINTVh  h= 1–240 (hours) 168  Monthly calling MCALLVn n= max. 14 digits –  Alarm calling ACALLiVn n= max. 14 digits –  Information number INFOSMSVn n= max. 14 digits –  Interval of sen
                    
                    Summary of the content on the page No. 19 
                    
                          8. Basic Technical Parameters    GB 051  ALARM tone  400 Hz  Inputs of SMS messages No. 1–8  Logical 0 0–0,5 V  Logical 1 4–6 V  Outputs of SMS messages No. 1–8   Logical 0 max. 0,8 V   for Iz= 5 mA  Logical 1 3,5–4,5 V    for Iz= 0,03 mA  GSM network  GSM 900/1800 MHz  SIM card Plug-in    Device  Power supply voltage 10–16 V DC   Peak power consumption during charging  350 mA (for 12 V)  Max. time of charging 4 hours  Power consumption with charged battery < 20 mA  Time of operation from back
                    
                    Summary of the content on the page No. 20 
                    
                          GUARANTEE CERTIFICATE       Product name: ..........…....................... Type: …….....…………....................………..     Production number: .…...................…. Date of sale: .............…………........………..     Signature: …………….............………. Seller (stamp): ………………………………..         Information about guarantee repairs:    Date of Date of Signature Description of defect  receipt  return                                                                                   Producer: LEVEL ltd.,