IPSO TMB795C user manual

User manual for the device IPSO TMB795C

Device: IPSO TMB795C
Category: Washer/Dryer
Manufacturer: IPSO
Size: 0.48 MB
Added : 5/11/2013
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for IPSO TMB795C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with IPSO TMB795C.

For your convenience

If looking through the IPSO TMB795C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual IPSO TMB795C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual IPSO TMB795C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
IPSO TMB795C User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual IPSO TMB795C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to IPSO TMB795C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

On-Premise
Laundry
Planning
Handbook
TM795C
TMB795C
50 and 75 Pound Tumblers
Through Serial No. 0904002963
Refer to Installation manual for full instructions.
4-08-44R3
June 2011

Summary of the content on the page No. 2

Tumblers – 50 and 75 ......................................................................... 2 Table of Introduction...................................................................................... 2 Model Identification .................................................................. 2 Contents Specifications and Dimensions ........................................................ 4 Cabinet Dimensions................................................................... 5 Exhaust Outlet L

Summary of the content on the page No. 3

Tumblers – 50 and 75 Introduction TMB795C TMB795C Model Identification Gas Steam/Thermal Oil Electric 50 Pound IPD50G2-IT050L IPD50G2-IT050N IPD50S2-IT050S IPD50S2-IT050T IPD50E2-IT050E 75 Pound IPD75G2-IT075L IPD75G2-IT075N IPD75S2-IT075S IPD75S2-IT075T IPD75E2-IT075E Includes models with the following control suffixes: 3V – DX4 vended QT – dual digital timer SD – single drop 3X – DX4 prep for coin RD – reversing DMP OPL SX – single drop, prep for coin DO – DMP OPL RQ – reversing dual digital t

Summary of the content on the page No. 4

Tumblers – 50 and 75 1 1 TMB803N TMB803N 1 Serial Plate Conversion Table Multiply By To Obtain Multiply By To Obtain Btu 0.252 kCal Pounds/sq. inch 0.06895 Bars Btu 1055 Joules Pounds/sq. inch 0.070 kg/sq. cm Inch 25.4 Millimeters Pounds (lbs.) 0.454 Kilograms Inches W.C. 0.036 Pounds/sq. inch Boiler Horsepower 33,479 Btu/hr. Inches W.C. 0.249 kPa Boiler Horsepower 34.5 lbs. steam/hr. 2 lb/inch (psi) 6.895 kPa CFM 0.471 liters/second 3 ft 28.32 Liters kW 3414 Btu/hr. © Copyright, Alliance Laundr

Summary of the content on the page No. 5

Tumblers – 50 and 75 Specifications and Dimensions Specifications 50 Pound 75 Pound 63 dBA 69 dBA Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor. 545 615 Net Weight (approximate): Pounds (kg) (247) (279) 37 x 30 37 x 36 Cylinder Size: Inches (mm) (940 x 762) (940 x 914) 50 75 Cylinder Capacity (dry weight): Pounds (kg) (22.7) (34) 8 8 Air Outlet Diameter: Inches (mm) (203) (203) 0.5 0.5 Maximum Static

Summary of the content on the page No. 6

Tumblers – 50 and 75 Cabinet Dimensions C E B D A G F TMB2210N AB Models CD E F G **** ** 50 30.75 in. 28.75 in. 28.25 in. 33.87 in. 47 in. 76.625 in. 38.625 in. 33 in. 29.5 in. Pound Gas and (781 mm) (730 mm) (717 mm) (860 mm) (1194 mm) (1946 mm) (981 mm) (838 mm) (749 mm) Electric 50 30.75 in. 28.75 in. 28.25 in. 33.87 in. 47 in. 80 in. 38.625 in. 33 in. 29.5 in. Pound (781 mm) (730 mm) (717 mm) (860 mm) (1194 mm) (2032 mm) (981 mm) (838 mm) (749 mm) Steam 75 30.75 in. 28.75 in. 28.25 in. 3

Summary of the content on the page No. 7

Tumblers – 50 and 75 Exhaust Outlet Locations B C A TMB811N ABC 5.375 in. 8 in. 13.375 in. (137 mm) (203 mm) (340 mm) 4-08-44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6

Summary of the content on the page No. 8

Tumblers – 50 and 75 Gas Connection Locations A B TMB812N Models Diameter A B 1/2 in. NPT 15.5 in. 65.75 in. 50 Pound (394 mm) (1670 mm) 1/2 in. NPT 15.75 in. 65.75 in. 75 Pound (400 mm) (1670 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-44 7

Summary of the content on the page No. 9

Tumblers – 50 and 75 Electrical Connection Locations A A B B TMB813N GAS AND STEAM ELECTRIC TMB813N Models A B 9.5 in. 63.5 in. Gas and Steam (241 mm) (1613 mm) 19 in. 64 in. Electric (483 mm) (1626 mm) NOTE: These figures are approximate dimensions only. 4-08-44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 8

Summary of the content on the page No. 10

Tumblers – 50 and 75 Steam Connection Locations A C B D TMB814N Diameter ABCD 15.25 in. 72.75 in. 7.5 in. 64.75 in. 3/4 in. NPT (387 mm) (1848 mm) (190 mm) (1645 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-44 9

Summary of the content on the page No. 11

Tumblers – 50 and 75 Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered. Remove the crate and protective cover as soon as possible and check the items listed on t

Summary of the content on the page No. 12

Tumblers – 50 and 75 Tumbler Enclosure WARNING To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances. W056 1 3 4 2 5 6 TMB2131N 7 8 TMB2131N NOTE: Shaded areas indicate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installation 2 Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the opening; zero

Summary of the content on the page No. 13

Tumblers – 50 and 75 Make-up air openings for a room containing Exhaust Requirements tumbler(s) and/or gas fired hot water heater or other gravity vented appliances must be increased WARNING sufficiently to prevent downdrafts in any of the vents when all tumblers are in operation. Do not locate A drying tumbler produces combustible gravity vented appliances between tumbler(s) and lint. To reduce the risk of fire, the tumbler make-up air openings. If it is necessary to duct make- must be

Summary of the content on the page No. 14

Tumblers – 50 and 75 NOTE: Exhaust ducts must be constructed of sheet Duct Equivalent Length of Rigid metal or other noncombustible material. Such Diameter Straight Duct ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel 6 in. (152 mm) One 90° elbow = 7 ft. (2.1 m) not less than 0.0195 inches (0.495 mm) thick. Local 8 in. (203 mm) One 90° elbow = 9.3 ft. (2.83 m) codes may require additional thickness. 10 in. (254 mm) One 90° elbow = 11.6 f

Summary of the content on the page No. 15

Tumblers – 50 and 75 3 4 2 1 5 TMB2103N TMB2103N 1 Removable strip of panel in framing wall to permit removal of tumbler from framing wall 2 Partition or bulkhead 3 Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm) 4 2 in. (51 mm) minimum clearance on both sides of duct 5 Exhaust airflow – maximum length of duct: 14 ft. (4.3 m) Figure 2 NOTE: Do not install wire mesh or screen in NOTE: Inside of duct must be smooth. Do not use exhaust duct opening

Summary of the content on the page No. 16

Tumblers – 50 and 75 Manifold Venting NOTE: Never connect a tumbler duct at a 90° angle to the collector duct. Refer to Figure 3. Doing While it is preferable to exhaust tumblers individually so will cause excessive back pressure, resulting in to the outdoors, a main collector duct may be used if it poor performance. Never connect two tumbler is sized according to Figure 4 and Figure 5. This exhaust ducts directly across from each other at the illustration indicates minimum diameters, wh

Summary of the content on the page No. 17

Tumblers – 50 and 75 1 2 LK J I H G F E DC B A 3 ONE MANIFOLD ASSEMBLY TMB2019N 1 NOTE: Where the exhaust duct pierces a 2 Outlet duct diameter combustible wall or ceiling, the opening 3 45° typical MUST be sized per local codes. Figure 4 Duct Station 8 in. (203 mm) Duct 8 in. (203 mm) A 12 in. (305 mm) B 15 in. (381 mm) C 17 in. (432 mm) D 19 in. (483 mm) E 21 in. (533 mm) F 23 in. (584 mm) G 25 in. (635 mm) H 26 in. (660 mm) I 27 in. (686 mm) J 29 in. (737 mm) K 30 in. (762 mm) L Table 2 4-

Summary of the content on the page No. 18

Tumblers – 50 and 75 1 2 L LK J I J K I CONTINUE CONTINUE TO A TO A 3 TWO MANIFOLD ASSEMBLIES TMB2018N 1 NOTE: Where the exhaust duct pierces a 2 Outlet duct diameter combustible wall or ceiling, the opening 3 45° typical MUST be sized per local codes. Figure 5 Duct Station 8 in. (203 mm) Duct 13 in. (330 mm) A 17 in. (432 mm) B 18 in. (457 mm) C 24 in. (610 mm) D 27 in. (686 mm) E 30 in. (762 mm) F 33 in. (838 mm) G 34 in. (864 mm) H 37 in. (940 mm) I 39 in. (991 mm) J 40 in. (1016 mm) K 42

Summary of the content on the page No. 19

Tumblers – 50 and 75 NOTE: Electrical specifications below are subject 50 Pound Gas and Steam Models to change without notice. Always refer to product Refer to Table 4. serial plate for most current specifications of product being installed. NOTE: Wire sizes were obtained from the Canadian Electrical Code for 75 C. wire and are NOTE: Use copper conductors only. intended for use as a guideline only. Electrical NOTE: Connect to individual branch circuit. connections should be made by a quali

Summary of the content on the page No. 20

Tumblers – 50 and 75 NOTE: Use copper conductors only. 75 Pound Gas and Steam Models NOTE: Connect to individual branch circuit. Refer to Table 5. NOTE: 3 Phase Only – Each tumbler must be NOTE: Wire size and breaker ratings were connected to its own individual branch circuit obtained from the Canadian Electrical Code for breaker, not fuses, to avoid the possibility of “single 75 C. wire and are intended for use as a guideline phasing” and causing premature failure of the only. Electrical


Alternative user manuals
# User manual Category Download
1 Harman-Kardon TC600 User manual Washer/Dryer 54
2 Admiral 3RATW3005TQ User manual Washer/Dryer 29
3 Advantek Networks AWN-USB-11N2 User manual Washer/Dryer 3
4 AEG L76475FL User manual Washer/Dryer 283
5 AEG 52630 User manual Washer/Dryer 255
6 AEG LAVAMAT 12710 User manual Washer/Dryer 189
7 AEG L 71060 SL User manual Washer/Dryer 17
8 AEG KO-LAVAMAT 1271 User manual Washer/Dryer 116
9 AEG L14850 User manual Washer/Dryer 182
10 AEG 16850 User manual Washer/Dryer 272
11 AEG LAVAMAT 16810 User manual Washer/Dryer 122
12 AEG LAVAMAT 12700 User manual Washer/Dryer 982
13 AEG LAVAMAT 16950A3 User manual Washer/Dryer 220
14 AEG LAVAMAT 88810 User manual Washer/Dryer 21
15 AEG LAVAMAT L 14840 User manual Washer/Dryer 68