Carrier 48MPD user manual

User manual for the device Carrier 48MPD

Device: Carrier 48MPD
Category: Heating System
Manufacturer: Carrier
Size: 1.58 MB
Added : 8/8/2014
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 48MPD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 48MPD.

For your convenience

If looking through the Carrier 48MPD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 48MPD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 48MPD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 48MPD User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 48MPD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 48MPD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

48MPD,MPE62L-10R
50MP62L-10R
Single Package Electric Cooling Units
and Gas Heating/Electric Cooling Units
With Product Integrated Controls
Installation, Start-Up and Service
Instructions
CONTENTS
Page Page
Gas Pressure Check ........................38
GENERAL ................................. 2
Check Supply Fan Rotation................. 38
SAFETY CONSIDERATIONS................. 2
START-UP ................................38-42
INSTALLATION ............................ 3-28
Initial Check .........

Summary of the content on the page No. 2

CONTENTS (cont) Page Page Main Burners ...............................52 Lubrication ................................ 47 • MAIN BURNER REMOVAL • COMPRESSORS Protective Devices ......................... 52 • FAN SHAFT BEARINGS • COMPRESSOR PROTECTION • FAN MOTOR BEARINGS • EVAPORATOR-FAN MOTOR PROTECTION • DOOR HINGES • CONDENSER-FAN MOTOR PROTECTION Coil Cleaning .............................. 47 • HIGH-AND LOW-PRESSURE SWITCHES Refrigerant Circuit ......................... 47 Variable Frequency

Summary of the content on the page No. 3

Secure all ducts to the building structure, using flexible INSTALLATION ductconnectorsbetweenroofcurbandductsasrequired.Ducts JobsiteSurvey— Complete the following checks be- passing through an unconditioned space must be insulated fore installation. andcoveredwithavaporbarrier.Outletgrillesmustnotlie directly below unit discharge. The return duct must have a 1. Consult local building codes and the NEC (National 90-degree elbow before opening into the building space if Electrical Code) (ANSI/NFPA

Summary of the content on the page No. 4

Table 1 — Physical Data BASE UNIT 48/50MP 62L 70M 82N NOMINAL CAPACITY (tons) 80 90 105 OPERATING WEIGHT (lb) Base Unit (48MP/50MP) 16,810/16,550 18,060/17,800 22,660/22,400 Copper Condenser Coils 675 725 725 Exhaust Fan 1,675 1,775 2,375 COMPRESSORS Semi-Hermetic Number of Refrigerant Circuits 22 2 Circuit (No. of Cylinders) A(6) B (6) A1 (6),A2 (4) B (6) A1 (6),A2 (4) B1 (6), B2 (6) Model 06E −299 −299 −275, −250 −299 −265, −250 −265, −265 Oil Charge (pints) 19 19 19, 14 19 19, 14 19,19 Capaci

Summary of the content on the page No. 5

Table1 — Physical Data (cont) BASE UNIT 48/50MP 90P 10R NOMINAL CAPACITY (tons) 115 120 OPERATING WEIGHT (lb) Base Unit (48MP/50MP) 24,660/24,750 25,110/25,100 Copper Condenser Coils 950 950 Exhaust Fan 2400 2400 COMPRESSORS Semi-Hermetic Number of Refrigerant Circuits 22 Circuit (No. of Cylinders) A1 (6),A2 (6) B1 (6), B2 (6) A1 (6),A2 (6) B1 (6), B2 (6) Model 06E −265, −275 −265, −275 −265, −299 −265, −275 Oil Charge (pints) 19, 19 19, 19 19, 19 19, 19 Capacity Steps (%) 15,23,30,38,45,58,65,7

Summary of the content on the page No. 6

Table 2 — Optional Power Exhaust Specifications UNIT 48/50MP 62L 70M 82N Type 100% Mod 100% Non Mod 100% Mod 100% Non Mod 100% Mod 100% Non Mod Motor Hp 30 30 40 40 40 40 Motor Frame Size 286T 286T 324T 324T 324T 324T Efficiency at Full Load (%) Standard Efficiency 92.4 92.4 93.0 93.0 93.0 93.0 High Efficiency 93.6 93.6 94.5 94.5 94.5 94.5 Fan Pulley Pitch Diameter (in.) 18.4 18.4 18.4 18.4 25.0 20.0 Motor Pulley Pitch Diameter (in.) 5.6 6.0 6.2 6.6 6.8 5.8 Fan Rpm 552 590 608 646 491 526 Belts Q

Summary of the content on the page No. 7

NOTES: 1. Roof curb is shipped disassembled. 2. Roof curb: 14 gage [VA03-56] steel. 3. Dimensions in [ ] are in millimeters. 4. Topreventstandingwaterinthedrainpanofthe indoor section, roof curb and unit must be level within tolerances shown. NOTES: 1. Topreventthehazardofstagnantwaterbuild-upinthedrainpanontheindoorsection,unitcannot exceed leveling tolerances shown. 2. IfaCarrierroofcurbisnotused,curbcrossrailsmustbepostionedtoclearunitbaseraillocations shown. Fig. 1 — Roof Curb Dimensions, 48

Summary of the content on the page No. 8

NOTES: 1. Roof curb is shipped disassembled. 2. Roof curb: 14 gage [VA03-56] steel. 3. Dimensions in [ ] are in millimeters. 4. Topreventstandingwaterinthedrainpanofthe indoor section, roof curb and unit must be level within tolerances shown. NOTES: 1. Topreventthehazardofstagnantwaterbuild-upinthedrainpanontheindoorsection,unitcannot exceed leveling tolerances shown. 2. IfaCarrierroofcurbisnotused,curbcrossrailsmustbepostionedtoclearunitbaseraillocations shown. Fig. 2 — Roof Curb Dimensions, 48

Summary of the content on the page No. 9

WEIGHT A B C D E F UNIT SIZE 48MPD,E lb kg mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. 11 5 3 1 1 62L 16,810 7624 3505 11- 6 957 3-1 ⁄16 5909 19-4 ⁄8 1203 3-11 ⁄8 13 011 42-8 ⁄4 14 256 46-9 ⁄4 9 7 3 3 1 1 70M 18,060 8190 3647 11-11 ⁄16 1165 3-9 ⁄8 6166 20-2 ⁄4 1264 4- 1 ⁄4 13 297 43-7 ⁄2 14 542 47-8 ⁄2 NOTES: 1. Dimensions in [ ] are in millimeters. 2. Centerofgravityincludesexhaustfanandhighheatoptions.Unitweightdoesnotincludeexhaustfanorhigh heat options. 3. High heat add: 260

Summary of the content on the page No. 10

WEIGHT A B C D E F UNIT SIZE 48MPD,E lb kg mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. 9 1 1 1 82N 22,660 10295 3646 11-11 ⁄16 — — 6734 22- 1 ⁄8 1753 5-9 13 957 45-9 ⁄2 15 202 49-10 ⁄2 5 1 3 1 1 1 90P 24,660 11203 1938 6- 4 ⁄16 2572 8-5 ⁄4 7283 23-10 ⁄4 1765 5-9 ⁄2 14 821 48-7 ⁄2 16 066 52- 8 ⁄2 5 1 1 1 1 1 10R 25,110 11408 1938 6- 4 ⁄16 2572 8-5 ⁄4 7268 23-10 ⁄8 1759 5-9 ⁄4 14 821 48-7 ⁄2 16 066 52- 8 ⁄2 NOTES: 4. Unit clearances: 1. Dimensions in [ ] are in millimeters. Top — D

Summary of the content on the page No. 11

WEIGHT C1 C2 UNIT AB DE F (See Note 3) (See Note 2) (See Note 2) SIZE 50MP lb kg mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. 11 1 3 1 1 62L 16,550 7511 3505 118-69 957 38-1 ⁄169 5880 198-3 ⁄29 6325 208-99 1203 38-11 ⁄89 13 011 428-8 ⁄49 14 256 468-9 ⁄49 9 7 3 3 3 1 1 70M 17,800 8078 3647 118-11 ⁄169 1165 38-9 ⁄8 6166 208-2 ⁄4 6649 218-9 ⁄49 1264 48-1⁄49 13 297 438-7 ⁄29 14 542 478-8 ⁄29 NOTES: Sides — 68-09 1. Dimensions in [ ] are in millimeters. Economizer End — 68-09

Summary of the content on the page No. 12

WEIGHT C1 C2 UNIT AB DE F (See Note 3) (See Note 2) (See Note 2) SIZE 50MP lb kg mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. 9 7 11 1 1 82N 22,400 10 295 3646 118-11 ⁄169 — — 6702 218-11 ⁄89 7180 238-6 ⁄169 1753 58-99 13 957 458-9 ⁄29 15 202 498-10 ⁄29 5 1 3 9 1 1 1 90P 24,750 11 375 1938 68-4⁄169 2572 88-5 ⁄4 7383 238-10 ⁄4 7787 258-6 ⁄169 1765 58-9 ⁄29 14 821 488-7 ⁄29 16 066 528-8 ⁄29 5 1 1 13 1 1 1 10R 25,100 11 536 1938 68-4⁄169 2572 88-5 ⁄4 7383 238-10 ⁄8 7793 258

Summary of the content on the page No. 13

NOTICE TO RIGGERS WEIGHT A BCD E UNIT Unit 48MP Unit 50MP Exhaust Fan SIZE lb kg lb kg lb kg in. mm in. mm in. mm in. mm in. mm 62L 16,810 7 624 16,550 7 507 1675 760 71.25 1810 129.00 3277 112.44 2856 138.00 3505 N/A N/A 70M 18,060 8 190 17,800 8 074 1775 805 71.25 1810 129.00 3277 112.44 2856 143.56 3646 N/A N/A 82N 22,660 10 295 22,400 10 161 2275 1032 71.25 1810 139.56 3545 127.87 3248 143.56 3646 N/A N/A 90P 24,660 11 203 24,750 11 227 2400 1089 71.25 1810 139.56 3545 127.87 3248 177.56 451

Summary of the content on the page No. 14

Field Electrical Connections IMPORTANT: The 48/50MPunits generate, use, and UNIT PITCH DRAIN LINE BASE canradiateradiofrequencyenergy.Ifunitsarenotin- SEALANT TO OFFSET LINE RAIL stalledandusedinaccordancewiththeseinstructions, FRICTION theymaycauseradiointerference.Theyhavebeentested SLAB and found to comply with limits of a Class A com- puting device as defined by FCC (Federal Communi- 2" MIN. cationsCommission)regulations,SubpartJofPart15, which are designed to provide reasonable protection 7"

Summary of the content on the page No. 15

Disconnectmustbelocatedwithinsightoftheunitandread- Thisamountofphaseimbalanceissatisfactoryasitisbe- ily accessible from the unit in compliance with NEC low the maximum allowable 2%. Article 440-14. AllfieldwiringmustcomplywithNECandalllocalcodes. IMPORTANT: If the supply voltage phase imbalance Size wire based on MCA (Minimum Circuit Amps) value is more than 2%, contact local utility immediately. shown on the unit informative plate. See Fig. 12 for power wiringconnectionstotheunitpowerterminalb

Summary of the content on the page No. 16

Table 5 — Electrical Data CONDENSER POWER VOLTAGE COMP COMP COMP COMP EVAPORATOR UNIT FAN EXHAUST VOLTAGE RANGE NO. A1 NO. A2 NO. B1 NO. B2 FAN MOTOR 48MP/ MCA MOCP MOTORS FAN MOTOR 3 Ph, 60 Hz 50MP Min Max RLA LRA RLA LRA RLA LRA RLA LRA Qty FLA Hp FLA Hp FLA Hp — — 207.0 250 40 30 11 7.5 218.0 250 40 30 247.0 300 — — 219.0 250 62L 460 414 508 65.4 345 — — 65.4 345 — — 6 3.3 1 52 40 11 7.5 230.0 250 40 30 259.0 300 — — 232.0 250 65 50 11 7.5 243.0 300 40 30 272.0 300 — — 235.0 300 52 40 11 7.5

Summary of the content on the page No. 17

pins E2 and E3, and an RJ11 female connector. The RJ11 Control Wiring — See Fig. 13 for sensor wiring con- connectorisusedtotapintotheCCNatthesensor.SeeRJ11 nections to main and auxiliary control boxes. The recom- Plug Wiring section on page 24 to connect the RJ11 con- mended types of control wiring for 48/50MP unit devices nector to the CCN. are shown in Table 6. Table 6 — Recommended Sensor and Jumper MUST be in place between pins E2 and E3 or Device Non-Shielded Cable inaccurate readings coul

Summary of the content on the page No. 18

LEGEND COM — Common SW — Switch T— Terminal TB — Terminal Block TH — Thermostat Heating Accessory Field Wiring *Constantvolumeapplicationsonly. Fig. 13 — Space Temperature Sensor Wiring 18

Summary of the content on the page No. 19

RED RED BLK BLK TB3 RED RED RED 1 BLK BLK BLK 2 TO PROCESSOR MODULE NO. 1 SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 SPACE TEMPERATUREAVERAGING — 4 SENSORAPPLICATION TB3 RED RED RED 1 BLK BLK BLK 2 TO PROCESSOR MODULE NO. 1 SENSOR 1 SENSOR 2 SENSOR 3 RED RED BLK BLK SENSOR 4 SENSOR 5 SENSOR 6 RED RED BLK BLK LEGEND TB — Terminal Block Factory Wiring Field Wiring SENSOR 7 SENSOR 8 SENSOR 9 SPACE TEMPERATUREAVERAGING — 9 SENSORAPPLICATION Fig. 14 — Space Temperature Sensor Averaging 19 BLK BLK RED RED

Summary of the content on the page No. 20

FIELD-SUPPLIED ACCESSORY DSIO2 24-V ISOLATED J5 POWER SUPPLY OUTSIDE AIR RELATIVE HUMIDITY FIELD TB3 TB3 CONTROL WIRING 12 RED 8 7 2 1 24V J1 J2 1 12 2 11 BLU 9 FIELD-SUPPLIED 24-V ISOLATED POWER SUPPLY 13 ORN 10 10 2 1 CHANNEL 15 J1 J2 60 1 2 24V LEGEND SPACE/RETURN TB — Terminal Block RELATIVE HUMIDITY Field Wiring Component Terminal LEGEND h Terminal Block Terminal TB — Terminal Block Field Wiring Fig. 15 — Heat Interlock Relay Component Terminal h Terminal Block Terminal


Alternative user manuals
# User manual Category Download
1 Carrier 48LJE User manual Heating System 9
2 Carrier 48DD User manual Heating System 4
3 Carrier 48NET User manual Heating System 2
4 Carrier 48MA/50ME016-040 User manual Heating System 10
5 Carrier 48NHT User manual Heating System 8
6 Carrier 48LJD User manual Heating System 1
7 Carrier 48DJD User manual Heating System 5
8 Carrier 48DJE User manual Heating System 11
9 Carrier 48NVT User manual Heating System 1
10 Carrier 48NLT User manual Heating System 3
11 Carrier 48PD05 User manual Heating System 1
12 Carrier 48NMT User manual Heating System 0
13 Carrier 48PG03---16 User manual Heating System 1
14 Carrier 48TJE004-014 User manual Heating System 8
15 Carrier 48TJF004-012 User manual Heating System 9
16 Allied Air Enterprises 506299-01 User manual Heating System 1
17 Amtrol User manual Heating System 3
18 Atmos Energy HE26 User manual Heating System 0
19 Atmos Energy INTERCOMBI HE32 User manual Heating System 6
20 Bard Mfg. Co.EHP513-A10 User manual Heating System 1