Charnwood SLX20 user manual

User manual for the device Charnwood SLX20

Device: Charnwood SLX20
Category: Gas Heater
Manufacturer: Charnwood
Size: 0.28 MB
Added : 4/2/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Charnwood SLX20. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Charnwood SLX20.

For your convenience

If looking through the Charnwood SLX20 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Charnwood SLX20 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Charnwood SLX20 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Charnwood SLX20 User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Charnwood SLX20 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Charnwood SLX20. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CHARNWOOD
SLX20 Multi-Fuel
Roomheater
Operating
and
Installation Instructions
Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
Tel: +44(0)1983 537799 Fax: +44(0)1983 537788
E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com

Summary of the content on the page No. 2

CHARNWOOD SLX20 Operating and Installation Instructions Contents Operating Instructions General Points...................3 Fuels..........................3 Door Operation.................4 Multifuel Grate ..................4 Lighting........................3 Controlling The Fire ..............4 Running With The Doors Open.....4 Ash Clearance...................4 Riddling........................5 Refuelling ......................5 Overnight Burning................5 Throat Plate and Flueway Cleanin

Summary of the content on the page No. 3

OPERATING INSTRUCTIONS FOR THE CHARNWOOD SLX20 GENERAL POINTS PETROLEUM COKE IS NOT SUITABLE FOR USE ON Before lighting the fire check with the installer that the work THIS APPLIANCE, ITS USE WILL INVALIDATE THE and checks described in the installation instructions have GUARANTEE been carried out correctly and that the chimney has been swept, is sound, and free of any obstructions. At first you may find it helpful to try several fuels to find the WARNING There must not be an extractor fan fitted

Summary of the content on the page No. 4

DOOR OPERATION The doors are opened by raising the door handle as shown in Fig. 1.Whenthefireisalight,avoidtouchingthedoors other than on the knobs as the metal will become hot. When closing the doors do not use excessive force. MULTIFUEL GRATE Your Charnwood is fitted witha multifuel grate which enables solid fuel, wood and peat to be burned equally effectively. The grate has two positions. One for solid fuel, the other for wood and peat.When in the solid fuel position ash can fall through the

Summary of the content on the page No. 5

THROAT PLATE AND FLUEWAY To make ash removal easier there isa special Charnwood CLEANING ash carrier available. This may be purchased from you supplier or, in case of difficulty, from ourselves. It is important that the throat plate and all the appliance RIDDLING flueways are kept clean. When burning smokeless fuels they should be cleaned at least monthly. When burning other Riddling twicea day is usually sufficient. fuels they should be cleaned oncea week, and more frequently if found necessary

Summary of the content on the page No. 6

When not in use b) the thermostat knob is turned down to the minimum setting and the airwash is closed, If the fire is going to be out of use fora long period, (for c) the air inlet damper is closed (at the bottom left of the instance in the summer,) then to prevent condensation, and appliance, see Fig. 1.) and that it is not prevented from hence corrosion, the thermostat should be left at the closing completely bya piece of ash, maximum setting and the main doors left ajar. It is also d)a suita

Summary of the content on the page No. 7

glass clean, therefore, when lighting the stove allow the It is always more difficult to keep the glass clean when firebed to become well established before turning the running the stove very slowly for long periods. thermostat down. It may sometimes be beneficial to also keep the doors slightly ajar whilst the fire becomes If blackening of the glass still occurs check that all flue established. This can also apply when re-fuelling. connections are well sealed. It is also important that the b) W

Summary of the content on the page No. 8

INSTALLATION INSTRUCTIONS FOR THE CHARNWOOD SLX20 checked, it must be in good condition, free from cracks and HEALTH AND SAFETY blockages, and should not havea excessive cross sectional PRECAUTIONS area (e.g. Greater than 250mmx 250mm). If you find that the chimney is in poor condition then expert advice should WARNING please take care when installing the appliance be sought regarding the necessity of having the chimney that the requirements of the Health and Safety at Work Act lined. If it foun

Summary of the content on the page No. 9

the open vent. The shaded area on the face of If an indirect cylinder is used then the primary circuit should the surround is the minimum flat be filled witha suitable inhibitor to prevent the build up of area required. scale and corrosion. 750 mm FITTING THE OPTIONAL ADD-IN B 660 mm A BOILER The boiler replaces the rear firebrick and is reversible so Dim. A: that the 1” B.S.P. male tappings may come on either the left Max. 470mm (18 1/2") Min. 405mm (16") or the right hand side of the boiler. D

Summary of the content on the page No. 10

Replace the back fireplate, the side fireplates, the front firebar and the throat plate. Flaunching Connect the boiler to the heating system ensuring that the Take Flue Pipe flow pipe rises from the boiler. Fill the system with water Up To Narrowest and check for leaks. Part Of Chimney. FLUE CONNECTION 150° Elbow Part No. 010/AV12 AND INFILLING Make the flue connection with the special 150° elbow, Part No. 010/AV12. Please note that this item is ordered Vermiculite separately from the appliance.

Summary of the content on the page No. 11

ASSEMBLY Fit the side panels and the hood onto the appliance. Instructions for this are enclosed with the panel pack. Replace any internal parts previously removed. PRE LIGHTING CHECK Before initial lighting check the following points: 1. The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated. 2. The plates round the sides and back of the grate must be in position and sitting correctly. 3. The throat plate must be fitted in the roof of


Alternative user manuals
# User manual Category Download
1 Charnwood DX20i MkII User manual Gas Heater 0
2 Allied Air Enterprises 506271-01 User manual Gas Heater 0
3 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
4 Breckwell ECONOMY P22FSL User manual Gas Heater 0
5 Breckwell ECONOMY P22FSA User manual Gas Heater 0
6 Breckwell ECONOMY P22I User manual Gas Heater 1
7 Briggs & Stratton 32K400 User manual Gas Heater 2
8 Bryan Boilers CLM240WP User manual Gas Heater 2
9 Bryan Boilers CLM180WP User manual Gas Heater 0
10 Bryan Boilers CLM270WP User manual Gas Heater 1
11 Bryan Boilers CLM300WP User manual Gas Heater 0
12 Bryan Boilers CLM90WP User manual Gas Heater 0
13 Cannon CANTFS-03-NG User manual Gas Heater 0
14 Cannon CANTFS-03-LP User manual Gas Heater 0
15 Bryant 585A/YAC User manual Gas Heater 7