Intel 945GZ user manual

User manual for the device Intel 945GZ

Device: Intel 945GZ
Category: Chipper
Manufacturer: Intel
Size: 0.7 MB
Added : 3/3/2013
Number of pages: 39
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Intel 945GZ. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Intel 945GZ.

For your convenience

If looking through the Intel 945GZ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Intel 945GZ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Intel 945GZ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Intel 945GZ User manual - Online PDF
Advertisement
« Page 1 of 39 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Intel 945GZ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Intel 945GZ. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1








®
Intel 945G/945GZ/945GC/
945P/945PL Express Chipset
Family

Thermal and Mechanical Design Guidelines (TMDG)
®
- For the Intel 82945G/82945GZ/82945GC Graphics Memory
®
Controller Hub (GMCH) and Intel 82945P/82945PL Memory
Controller Hub (MCH)


February 2008

















Document Number: 307504-004

Summary of the content on the page No. 2

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELA

Summary of the content on the page No. 3

Contents 1 Introduction.....................................................................................................7 1.1 Terminology ..........................................................................................8 1.2 Reference Documents .............................................................................9 2 Product Specifications......................................................................................11 2.1 Package Description..............

Summary of the content on the page No. 4

Figures Figure 1. (G)MCH Non-Grid Array ......................................................................12 Figure 2. 0° Angle Attach Methodology (top view, not to scale)..............................16 Figure 3. 0° Angle Attach Heatsink Modifications (generic heatsink side and bottom view shown, not to scale)...........................................................................16 Figure 4. Airflow Temperature Measurement Locations .........................................

Summary of the content on the page No. 5

Revision History Revision Description Date Number -001 • Initial Release May 2005 ® -002 • Added Intel 82945PL specifications October 2005 ® -003 • Added Intel 82945GZ specifications December 2005 ® -004 • Added Intel 82945GC specifications February 2008 § Thermal and Mechanical Design Guidelines 5

Summary of the content on the page No. 6

6 Thermal and Mechanical Design Guidelines

Summary of the content on the page No. 7

Introduction 1 Introduction As the complexity of computer systems increases, so do power dissipation requirements. The additional power of next generation systems must be properly dissipated. Heat can be dissipated using improved system cooling, selective use of ducting, and/or active/passive heatsinks. The objective of thermal management is to ensure that the temperatures of all components in a system are maintained within functional limits. The functional temperature limit is the

Summary of the content on the page No. 8

Introduction 1.1 Terminology Term Description BGA Ball Grid Array. A package type defined by a resin-fiber substrate where a die is mounted and bonded. The primary electrical interface is an array of solder balls attached to the substrate opposite the die and molding compound. FC-BGA Flip Chip Ball Grid Array. A package type defined by a plastic substrate where a die is mounted using an underfill C4 (Controlled Collapse Chip Connection) attach style. The primary electrical interfa

Summary of the content on the page No. 9

Introduction 1.2 Reference Documents Document Comments ® Intel 945G/945GZ/945P/945PL Express Chipset Family http://developer.intel.com/des Datasheet ign/chipsets/datashts/307502. htm ® Intel I/O Controller Hub 7 (ICH7) Datasheet http://developer.intel.com//de sign/chipsets/datashts/30701 3.htm ® Intel I/O Controller Hub 7 (ICH7) Thermal Design Guidelines http://developer.intel.com//de sign/chipsets/designex/30701 5.htm ® ® Intel Pentium 4 Processor 670, 660, 650, 640, and 630 and htt

Summary of the content on the page No. 10

Introduction 10 Thermal and Mechanical Design Guidelines

Summary of the content on the page No. 11

Product Specifications 2 Product Specifications This chapter provides the package description and loading specifications. The chapter also provides component thermal specifications and thermal design power descriptions for the (G)MCH. 2.1 Package Description The (G)MCH is available in a 34 mm [1.34 in] x 34 mm [1.34 in] Flip Chip Ball Grid Array (FC-BGA) package with 1202 solder balls. The die size is currently 9.6 mm [0.378in] x 10.6 mm [0.417in]. A mechanical drawing of the pack

Summary of the content on the page No. 12

Product Specifications Figure 1. (G)MCH Non-Grid Array 2.2 Package Loading Specifications Table 1 provides static load specifications for the chipset package. This mechanical maximum load limit should not be exceeded during heatsink assembly, shipping conditions, or standard use conditions. Also, any mechanical system or component testing should not exceed the maximum limit. The chipset package substrate should not be used as a mechanical reference or load-bearing surface for the

Summary of the content on the page No. 13

Product Specifications 2.3 Thermal Specifications To ensure proper operation and reliability of the (G)MCH, the temperature must be at or below the maximum value specified in Table 2. System and component level thermal enhancements are required to dissipate the heat generated and maintain the (G)MCH within specifications. Chapter 3 provides the thermal metrology guidelines for case temperature measurements. The (G)MCH must also operate above the minimum case temperature specificat

Summary of the content on the page No. 14

Product Specifications 2.4.1 Methodology 2.4.1.1 Pre-Silicon To determine TDP for pre-silicon products in development, it is necessary to make estimates based on analytical models. These models rely on extensive knowledge of the past chipset power dissipation behavior along with knowledge of planned architectural and process changes that may affect TDP. Knowledge of applications available today and their ability to stress various components of the chipset is also included in the mo

Summary of the content on the page No. 15

Thermal Metrology 3 Thermal Metrology The system designer must measure temperatures to accurately determine the thermal performance of the system. Intel has established guidelines for proper techniques of measuring (G)MCH component case temperatures. 3.1 Case Temperature Measurements To ensure functionality and reliability, the (G)MCH is specified for proper operation when T is maintained at or below the maximum temperature listed in Table 2. The C surface temperature at the geome

Summary of the content on the page No. 16

Thermal Metrology Figure 2. 0° Angle Attach Methodology (top view, not to scale) Figure 3. 0° Angle Attach Heatsink Modifications (generic heatsink side and bottom view shown, not to scale) 3.2 Airflow Characterization Figure 4 describes the recommended location for air temperature measurements measured relative to the component. For a more accurate measurement of the average approach air temperature, Intel recommends averaging temperatures recorded from two thermocouples space

Summary of the content on the page No. 17

Thermal Metrology Figure 4. Airflow Temperature Measurement Locations Airflow velocity should be measured using industry standard air velocity sensors. Figure 4 Typical airflow sensor technology may include hot wire anemometers. provides guidance for airflow velocity measurement locations. These locations are for a typical JEDEC test setup and may not be compatible with chassis layouts due to the proximity of the processor to the (G)MCH. The user may have to adjust the locations

Summary of the content on the page No. 18

Thermal Metrology 18 Thermal and Mechanical Design Guidelines

Summary of the content on the page No. 19

Reference Thermal Solution 4 Reference Thermal Solution The reference component thermal solution for the (G)MCH for ATX platforms uses two ramp retainers, a wire preload clip, and four custom MB anchors. The Intel Balanced Technology Extended (BTX) reference design uses a Z-clip attach for the (G)MCH heatsink. This chapter provides detailed information on operating environment assumptions, heatsink manufacturing, and mechanical reliability requirements for the (G)MCH. 4.1 Operating

Summary of the content on the page No. 20

Airflow Direction Airflow Direction Reference Thermal Solution Figure 5. Processor Heatsink Orientation to Provide Airflow to (G)MCH Heatsink on an ATX Platform Airflow Direction Airflow Direction Airflow Direction Airflow Direction (G)MCH Heatsink Omi Directional Flow Processor Heatsink (Fan Not Shown) TOP VIEW Proc_HS_Orient_ATX Other methods exist for providing airflow to the (G)MCH heatsink, including the use of system fans and/or ducting, or the use of an attached fan (active he


Alternative user manuals
# User manual Category Download
1 Intel 945G User manual Chipper 1
2 Intel 945GC User manual Chipper 4
3 Intel 945P User manual Chipper 3
4 Intel 945PL User manual Chipper 1
5 Philips SVGA COLOUR MONITOR 7CM5209 User manual Chipper 0
6 Agri-Fab Chip-N-Vac 2468 User manual Chipper 1
7 Philips SVGA COLOUR MONITOR 7CM5279 User manual Chipper 2
8 Agri-Fab Chip-N-Vac 552493 User manual Chipper 0
9 Agri-Fab Chip-N-Vac 502493 User manual Chipper 1
10 Agri-Fab Chip-N-Vac 45-0253 User manual Chipper 0
11 Ashly CLX-52 User manual Chipper 16
12 Bolens 460 Series User manual Chipper 0
13 Ativa CS2171 User manual Chipper 0
14 Ativa CS 2165 User manual Chipper 0
15 Billy Goat TKD505SPT User manual Chipper 1