Graham Field fr566g user manual

User manual for the device Graham Field fr566g

Device: Graham Field fr566g
Category: Wheelchair
Manufacturer: Graham Field
Size: 1.06 MB
Added : 4/9/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Graham Field fr566g. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Graham Field fr566g.

For your convenience

If looking through the Graham Field fr566g user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Graham Field fr566g on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Graham Field fr566g to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Graham Field fr566g User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Graham Field fr566g but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Graham Field fr566g. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Series FR566G Deluxe Clinical Care Recliner
Series FR566DG Deluxe Clinical Care Recliner with Drop Arm
Series FR566GH Deluxe Clinical Care Recliner
with Heat and Massage
Series FR566DGH Deluxe Clinical Care Recliner with Drop Arm
with Heat and Massage
Assembly and Operating Instructions
IMPORTANT: READ THIS MANUAL BEFORE OPERATING YOUR LUMEX
FR566G / FR566DG / FR566GH / FR566DGH DELUXE CLINICAL CARE RECLINER.
SAVE THIS MANUAL FOR FUTURE USE.
THE MOST CURRENT VERSION OF THIS MANUAL CAN BE FOUN

Summary of the content on the page No. 2

CONTENTS INTRODUCTION. ....................................................................................................................................................... 3 INTENDED.USE. ................................................................................................................................................. 3 IMPORT ANT.SAFETY .PRECAUTIONS—PLEASE.READ.BEFORE.USE. ....................................................... 3 W ARNINGS. .....................................

Summary of the content on the page No. 3

INTRODUCTION This manual contains assembly, operation, and maintenance instructions for Lumex Clinical Care Recliners Series FR566G, FR566DG, FR566GH and FR566DGH. Read the entire manual carefully before using your recliner, and refer to it during use if you have questions. If you have further questions, please call Graham-Field / Lumex Technical Support at 770-447-1609. INTENDED USE Lumex Clinical Care Recliners are intended to make the care, treatment and recovery of patients easier and mo

Summary of the content on the page No. 4

. W ARNING:.This.product.has.a.maximum.weight.capacity.of.350.lb.(158.kg),.EVENL Y . DISTRIBUTED. . W ARNING:.Casters.must.be.locked.at.all.times,.except.during.transport. . W ARNING:.Unauthorized.modification.of.your.recliner.or.the.use.of.non-Lumex. replacement.parts.may.change.the.structure.of.the.recliner.and.could.create.a. hazardous.condition,.which.may.result.in.serious.injury.and.will.void.the.warranty . . W ARNING:.Notice.for.California.Customers-.California.Proposition.65.W ARNING: Thi

Summary of the content on the page No. 5

ASSEMBLY UNPACKING 1. Check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor. 2. Remove all packaging materials from recliner base. PRODUCT DESCRIPTION Features, FR566G and FR566GH upholstered back upholstered seat padded push handle upholstered armrest upholstered legrest / skirt upholstered footrest total locking caster fold down side table (total of 3 on recliner; black locking tab) frame rear direc

Summary of the content on the page No. 6

Features, FR566DG and FR566DGH upholstered back upholstered seat upholstered armrest padded push handle gas spring upholstered actuating lever legrest / skirt upholstered footrest fold down side table total locking caster frame (total of 3 on recliner; black locking tab) rear directional (swivel) locking caster removable side panel (right rear leg only; green locking tab) Clinical Care Recliner Series FR566DGH FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instruct

Summary of the content on the page No. 7

Upholstered Back Assembly, All Models upholstered back upholstered skirt threaded knobs upholstered back’s kd brackets steel tube mechanism’s bayonet links bracket and link to be even threaded knob through large hole in bayonet link kd bracket bayonet link 1. Lift the skirt on the rear of the upholstered back. To make assembly easier, hold skirt up with a small piece of tape to fully expose the kd (knock-down) brackets that are to be mated to the two bayonet lugs on the recliner mechanism. 2

Summary of the content on the page No. 8

OPERATION . W ARNING:.Disconnection.of.the.device:.In.case.of.emergency ,.always.disconnect. the.device.by.removing.the.power.cord.plug.from.the.power.outlet. TENTE® CASTERS, ALL MODELS . W ARNING:.Casters.must.be.locked.at.all.times,.except.during.transport. black actuator tab green actuator tab All Lumex Clinical Care Recliners now feature the latest design, all-plastic casters from TENTE. Specifically designed for use in healthcare environments, the new casters are easier to clean, easier

Summary of the content on the page No. 9

SIDE TABLE OPERATION, ALL MODELS To Raise Table side table (disengaged position) Raise the side table all the armrest way up and slide in toward the armrest until tabs engage 3 /8" clevis pin slots in mount bracket. Press attachment side table down lightly on table to ensure (engaged position) locking tabs are engaged. side table mount bracket To Lower Table tabs engage into Lift the side table up slightly slots on side table until tabs disengage slots and mount bracket pull table away fr

Summary of the content on the page No. 10

SIDE PANEL OPERATION For easy cleaning and access to the side and underside of the recliner, Lumex Clinical Care Recliners feature easy-to-remove side panels. FR566G and FR566GH To Remove Side Panel: depress panel tabs the two push buttons located side panel on the lower sides of frame. Pull side panel gently away and down from frame. There are tabs on the frame underneath the armrest that hold the side panel in place. To Install Side Panel: insert side panel into recliner frame by loca

Summary of the content on the page No. 11

RECLINER OPERATION, ALL MODELS The Lumex Series FR566G / FR566DG / FR566GH / FR566DGH recliners feature three positions for patient comfort. The fourth position is a Trendelenburg (or Shock Position) that must be activated by a caregiver. The Trendelenburg Position CANNOT be activated by a patient while in the recliner. In addition, this recliner features a back that can be repositioned via the Adjustment Lever located on the Push Handle on the back of the recliner. First Position The first

Summary of the content on the page No. 12

Upright Position Third Position The third position is the Second Recline Position and is also known as the “Full Recline” Upright Position position. This position is ideal for patient treatment, rest and reading. First Recline Position (TV Position) To Achieve Third Position / Second Recline Position: • Reclining by the patient: from the First Recline Position continue to push against the back by placing your hands on the armrests and continue to recline yourself to the Second Recline Positi

Summary of the content on the page No. 13

DROP ARM FUNCTION, FR566DG AND FR566DGH ONLY The Lumex Deluxe Clinical Care Recliner with Drop Arm (Series FR566DG and FR566DGH) features self-storing drop arms that are simple for the caregiver to actuate. By lowering the arm, a safer and easier lateral transfer for the resident and caregiver can be achieved. . W ARNING:. Always.lock.all.recliner.casters.before.attempting.to.transfer.a.patient.. DO NOT.attempt.to.transfer.a.patient.if.you.are.unsure.about.the.physical.abilities. of.the.patien

Summary of the content on the page No. 14

LUMEX CLINICAL CARE RECLINERS WITH HEAT AND MASSAGE FEATURE INSTALLATION AND OPERATING GUIDE Series FR566GH and FR566DGH 1 3 Tools Required: /4” Hex Wrench, /8” Hex Wrench, Phillips Screwdriver, masking or packaging tape . W ARNING:.Important!.Read.and.understand.these.instructions.before.assembling. or using.the.Specialty.Healthcare.Seating.Heat.and.Massage.Unit..If.you.do. not.understand.any.part.of.these.warnings,.cautions.or.instructions,.contact.a. healthcare.professional.for.direction.in.

Summary of the content on the page No. 15

Connection The Heat and Massage Unit comes pre-installed in Lumex Clinical Care Recliners with the Heat and Massage Option (FR566GH and FR566DGH). During recliner shipment, the Heat and Selector Switch connections are disconnected. Several easy connections are all that is required to make the unit functional. Main Components 1. The selector switch (shown at right), in the switch box mounted on the right side of the recliner underneath the armrest, is a single multi-position switch that

Summary of the content on the page No. 16

Heat and Massage Unit Setup Instructions 1. Place the back cushion over the vertical bayonet recliner mechanism lugs of the recliner mechanism. Secure back on each side with the threaded screw knobs enclosed knob with the Recliner Operating Instructions, as shown at right. 2. Raise the back skirt on the lower rear of the back cushion and use masking or packaging tape Knob Secure Back Cushion to to temporarily secure it up and out of the way. Recliner Mechanism This will permit uninterrup

Summary of the content on the page No. 17

Heat and Massage Unit Operation Instructions 1. Plug the power supply cord into any grounded outlet. 2. The Heat and Massage Unit is operated using the single multi-position selector switch located on the right side of the recliner underneath the armrest. The Heat and Massage functions can be operated independently. The selector switch faceplate is shown at right. 3. Press the selector switch UP to activate the HEAT FUNCTION. 4. Press the selector switch DOWN to activate the MASSAGE FUNCT

Summary of the content on the page No. 18

Heat and Massage Unit Troubleshooting Guide The cables and connections need to be validated. This will require the services of a maintenance person and a clear working area. 1. INSPECTION: Perform the following checks. If a working recliner of the same model is available, use it for comparison. 2. Is the AC cord properly connected to the power supply? Is the cable from the power supply to the control module junction box in place? 3. With the power supply AC cord plugged into a live wall outle

Summary of the content on the page No. 19

CARE AND MAINTENANCE . W ARNING:.Inspect.all.components.periodically.and.replace.as.needed. EVERY THREE MONTHS • Check and clean casters. • Tighten bolts in each leg that secure casters into frame. • Check brakes on casters. • Check and clean lock recline mechanism. • Check recliner mechanism for operation in all positions, including Trendelenburg Position, with assistant seated in recliner. UPHOLSTERY MAINTENANCE AND STAIN REMOVAL • Ordinary dirt: wash with warm water and a mild soap or deterg

Summary of the content on the page No. 20

The information published in this care guide refers to the performance of PERMABLOK3® products in specific tests conducted under laboratory conditions. Results may vary under actual conditions. This information is not a guarantee and does not relieve the user from the responsibility of the proper and safe use of the product and all cleaning agents. The use of certain agents can be harmful to the surface appearance and lifespan of vinyl. Spradling, its agents, and assigns assume no responsib


Alternative user manuals
# User manual Category Download
1 Graham Field FR566G User manual Mobility Aid 0
2 Graham Field 565WG User manual Wheelchair 0
3 Graham Field 565G User manual Wheelchair 1
4 Graham Field METRO IC4 User manual Wheelchair 1
5 Graham Field 565PG User manual Wheelchair 1
6 Graham Field WALKER TRAY 603900A User manual Wheelchair 1
7 Aiphone YAW-RB User manual Wheelchair 7
8 Aiphone GTW-LC User manual Wheelchair 1
9 Akros-Aquatherm TENDERFLO AQTF-2035 User manual Wheelchair 18
10 Akros-Aquatherm TENDERFLO AQTF-3013 User manual Wheelchair 2
11 Aprilaire 6504 User manual Wheelchair 0
12 ATD Tools Atd-7460 User manual Wheelchair 1
13 ATD Tools Atd-7477 User manual Wheelchair 0
14 ATD Tools ATD-9890 User manual Wheelchair 0
15 ATD Tools ATD7350 User manual Wheelchair 0