Sea-Fire FM200 user manual

User manual for the device Sea-Fire FM200

Device: Sea-Fire FM200
Category: Fire Extinguisher
Manufacturer: Sea-Fire
Size: 0.46 MB
Added : 10/30/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sea-Fire FM200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sea-Fire FM200.

For your convenience

If looking through the Sea-Fire FM200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sea-Fire FM200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sea-Fire FM200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sea-Fire FM200 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sea-Fire FM200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sea-Fire FM200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 11

FG/FD/FT/MD/R/C-MODEL Fire Extinguisher MSDS No. SF002 MATERIAL SAFETY DATA SHEET Section 1 — Company and Chemical Identification METALCRAFT/SEA-FIRE MARINE EMERGENCY PHONE: 1-800-535-5053 9331-A PHILADELPHIA ROAD PHONE: 1-800-445-7680 BALTIMORE, MARYLAND 21237DATE: NOVEMBER 10, 2005 http://www.sea-fire.com PRODUCT NAME: Fire Extinguisher Section 2 — Hazardous Ingredients/ Identity C.A.S. INGREDIENT NAME OSHA PEL ACGIH TLV OSHA STEL 431890 HEPTAFLUOROPROPANE NOT ESTAB. NOT ESTAB. NOT ESTAB. Sect

Summary of the content on the page No. 12

Section 7 — Handling and Storage Handle, transport and store carefully and securely to avoid accidental knocking over or other severe physical impacts. Do not expose to direct heat sources. Do not over-pressurize. Section 8 — Exposure Controls/Personal Protection Respiratory: None Protective Gloves: Leather gloves are recommended when handling cylinders. Eye Protection: Eye protection is recommended when handling cylinders. Other Protective Clothing or Equipment: Safety shoes are recommended whe

Summary of the content on the page No. 13

Section 15 — Regulatory Information U.S. Federal Regulations: The components of this product are either on the TSCA Inventory or exempt (i.e. impurities, a polymer complying with the exemption rule at 40 CFR 723.250) from the Inventory. State Regulations: None Known Section 16 — Other Information NFPA Codes: Health: 1 Flammability: 0 Reactivity: 0 Other: X NMIS Codes: Health: 1 Flammability: 0 Reactivity: 0 Protection: X DISCLAIMER OF EXPRESSED AND IMPLIED WARRANTIES: Metalcraft/Sea-Fire Marine,

Summary of the content on the page No. 14

SEA-FIRE MARINE SEA-FIRE EUROPE LTD Division of Metalcraft Inc. Unit 7. io Centre. Stephenson Road 9331-A Philadelphia Road Fareham, Hampshire Baltimore, Maryland 21237 USA PO15 5RU, United Kingdom Website: www.sea-fire.com 14

Summary of the content on the page No. 1

®
FM200
MODEL FT
FIRE EXTINGUISHERS
INSTALLATION INSTRUCTIONS
OWNER’S MANUAL
THIS MANUAL IS AN INTEGRAL PART OF THE SYSTEM AND AS SUCH, THE
EXTINGUISHER MUST BE INSTALLED AND MAINTAINED ACCORDINGLY.
READ AND COMPLY WITH THESE INSTRUCTIONS, WARNINGS
AND LIMITATIONS BEFORE INSTALLING.
SUITABLE FOR USE
FT MODELS: 32°F – 130°F ( 0°C – 54°C)
ALWAYS MAINTAIN THIS OWNER’S MANUAL NEARBY
FOR OPERATOR REFERENCE.
APPROVALS
FACTORY MUTUAL - FM # 3022058
U.S. COAST GUARD - U.S.C.G. # 162.029/241
REV. A PRINT

Summary of the content on the page No. 2

WARNING CONCENTRATED AGENT AND BY-PRODUCT OF APPLICATION TO FIRE ARE TOXIC. AVOID BREATHING OF FUMES OR PROLONGED EXPOSURE. ACCIDENTAL DIS- CHARGE MAY OCCUR DURING HANDLING OR INSTALLATION OF THIS DEVICE, READ AND COMPLY WITH INSTRUCTIONS, WARNINGS, AND LIMITATIONS CONTAINED IN THIS MANUAL. DO NOT LIFT, CARRY, OR HANDLE BY VALVE. DO NOT DROP. KEEP AWAY FROM HEAT. KEEP AWAY FROM CHILDREN. APPLICATION ® FM-200 (CF3CHFCF3), the extinguishing agent, used in all Sea-Fire “FT’’ series fire extin- ® gu

Summary of the content on the page No. 3

REMINDER: Sea-Fire systems shall be considered as supplementary to the number of portable fire extinguishers required on-board and are designed and intended for enclosed unoccupied compartment installations that are not subject to direct weather or water. SYSTEM OPERATIONS Sea-Fire units described in this manual are automatically actuated by a heat actuated tube. Discharge will occur as a result of direct flame impingement. The Sea-Fire FT system uses the supplied length of temperature sensitive

Summary of the content on the page No. 4

OTHER APPLICATIONS  Engine Compartments (maximum 150 cubic feet)  Bow Thrusters  Small Generator Set Enclosures  Consoles  Electrical Enclosures  Flammable Liquid Storage Areas  Pump Enclosures  Alternative Fuel Storage Areas In case of a fire and system discharged, the electrical supply to the motor must be discon- nected. Failure to do so may result in re-ignition after the FM-200® concentration depletes. Disconnect may be accomplished by using a shutdown system. See OPTIONAL EQUIPMENT

Summary of the content on the page No. 5

Figure 5 Step 8 Secure the detection tubing to the bulkhead by using the clips and screws supplied. Nylon wire ties may be used in lieu of the clips and screws. Note: Do not exceed a bend radius of 6 inches during the routing of the tube. WARNING WHEN INSTALLING THE DETECTION TUBING, DO NOT KINK THE TUBING AND DO NOT EXCEED THE MINIMUM BEND RADIUS. FAILURE TO FOLLOW THESE DIRECTIONS CAN RESULT IN A SYSTEM FAILURE. (See Figure 6) Step 9 Ensure the spring nut fitting is on tube, and attach by care

Summary of the content on the page No. 6

Figure 6 THE FT EXTINGUISHER INSTALLATION IS COMPLETE. INDICATOR LIGHT OPERATION All Sea-Fire extinguishers approved for marine applications are packaged with an indicator light and escutcheon. ‘‘The U.S. Coast Guard approval requires an indicator light if this unit is installed for the protection of a boat’s engine compartment.” The indicator light (unless re- placed by another Sea-Fire method) must be installed for system supervision and operator awareness. When properly installed, activation

Summary of the content on the page No. 7

Figure 9 INDICATOR LIGHT ELECTRICAL STARTER SWITCH IGNITION IGNITION SWITCH IN-LINE FUSE BATTERY GROUND Figure 3 WHILE MAKING ELECTRICAL CONNECTION CAN RESULT IN INJURY FROM FIRE OR ELECTRICAL BURNS. The indicator light is rated for 12 VDC (contact factory for other voltages). Wire in accor- dance with the American Boating and Yacht Council standard E-9 “Direct current Electri- cal System on Boats, copies of which may be obtained from ABYC, Edgewater, MD, USA 21037, 410-956-1050. Supplies, which

Summary of the content on the page No. 8

Before operating the protected vessel, visually inspect pressure gauge for compliance and ensure the supervisory (indicator) light is lit. If gauge reads low in pressure, and or the indica- tor light is extinguished, remove, and replace the system immediately. Never paint or obstruct the detection tube, as this will adversely affect its operating charac- teristic. FT models are non-refillable. See nameplate on cylinder for instructions and OUT OF WARRANTY REPLACEMENTS section of this manual. REM

Summary of the content on the page No. 9

CONDITIONS All Sea-Fire products are tested after manufacture and shipped in perfect working order. Damage noted upon receipt of shipment should be addressed as a shipping claim, the filing of which is the sole responsibility of the consignee for which the total compensatory award will be limited to that appropriated by the carrier. Insured freight costs are the responsibility of the consignee. Missing component parts and damage noted upon installation are typically the result of mishandling dur

Summary of the content on the page No. 10

ALL FT (STINGER) MODELS ARE APPROVED FOR VERTICAL MOUNTING ONLY. INTENDED OPERATING TEMPERATURE RANGE : 32°F –130°F (0°C – 54°C ) STANDARD EQUIPMENT LIST SUPPLIED WITH EACH SYSTEM 1. ONE TUBING KIT, PART # 130-121 – 10 FOOT TUBE OR 130-122 – 15 FOOT TUBE. 2. ONE BRACKET ASSEMBLY — Model # Bracket Part # FT-25 122-010 FT-50 122-010 FT-75 122-010 FT-100 130-011 FT-125 130-012 FT-150 130-013 10


Alternative user manuals
# User manual Category Download
1 Fireboy- Xintex, LTD MA2 FE-241 User manual Fire Extinguisher 21
2 Fireboy- Xintex, LTD CG2 User manual Fire Extinguisher 4
3 Fireboy- Xintex, LTD HFC-227ea User manual Fire Extinguisher 23
4 First Alert FE10G-M User manual Fire Extinguisher 0
5 First Alert FE4A60 User manual Fire Extinguisher 1
6 First Alert FE3A40 User manual Fire Extinguisher 2
7 First Alert FE10GO User manual Fire Extinguisher 3
8 First Alert FE3A10 User manual Fire Extinguisher 1
9 First Alert FE4A60B User manual Fire Extinguisher 2
10 First Alert FE5G User manual Fire Extinguisher 0
11 First Alert FE1A10G30 User manual Fire Extinguisher 3
12 First Alert FE1A10G User manual Fire Extinguisher 0
13 First Alert FE5GO User manual Fire Extinguisher 0
14 First Alert FE5G-M User manual Fire Extinguisher 0
15 First Alert KFE2S5 User manual Fire Extinguisher 1