Universal Security Instruments HEAT ALARM USI-2430 user manual

User manual for the device Universal Security Instruments HEAT ALARM USI-2430

Device: Universal Security Instruments HEAT ALARM USI-2430
Category: Smoke Alarm
Manufacturer: Universal Security Instruments
Size: 0.08 MB
Added : 5/17/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Universal Security Instruments HEAT ALARM USI-2430. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Universal Security Instruments HEAT ALARM USI-2430.

For your convenience

If looking through the Universal Security Instruments HEAT ALARM USI-2430 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Universal Security Instruments HEAT ALARM USI-2430 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Universal Security Instruments HEAT ALARM USI-2430 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Universal Security Instruments HEAT ALARM USI-2430 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Universal Security Instruments HEAT ALARM USI-2430 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Universal Security Instruments HEAT ALARM USI-2430. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Visit Us on the Web! www.SmokeAlarms.com
MODEL USI-2430
HEAT ALARM
120 VAC WITH
9V BATTERY BACKUP
OWNER'S MANUAL
PLEASE READ AND SAVE!
Installer: Please leave this manual with the product.
WHAT YOU SHOULD KNOW ABOUT HEAT ALARMS
Heat alarms are not life safety devices and are not designed to detect
o
smoke or fire. They are intended to detect temperatures of 135 F to
provide an additional source of information that is supplemental to
smoke alarms to increase the probability that an early warning

Summary of the content on the page No. 2

• Maximum alarm coverage has been determined by UL to provide detection time equal to sprinkler devices spaced at 10 foot intervals (100 square foot area) on a smooth ceiling 15 ft. x 8 in. high. Higher ceilings can adversely affect detection time. In some instances, earlier detection may be obtained by reducing the spacing between detectors. See the latest edition of NFPA 72, National Fire Alarm Code. • Maximum distance is from any wall partition or ceiling projection extending down more than 1

Summary of the content on the page No. 3

o • This heat alarm can only sound its alarm when it detects temperatures of 135 F or greater. Heat alarms do not sense smoke, fire or gas. In some fires, hazardous levels of toxic chemicals and smoke can build up before a heat alarm will operate. o Temperatures may not reach 135 F to activate the heat alarm quickly enough to ensure safe escape. • Heat alarms have limitations. This heat alarm is not foolproof and is not warranted to protect lives or property. Heat alarms are not a substitute for

Summary of the content on the page No. 4

NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information, the National Fire Protection Association's Standard 72, reads as follows: “11.5.1 One- and Two-Family Dwelling Units. 11.5.1.1 Smoke Detection. Where required by applicable laws, codes, or standards for the specified occupancy, approved single- and multiple-station smoke alarms shall be installed as follows: (1) In all sleeping rooms. Exception: Smoke alarms shall not be required in sleeping rooms in existing one- and

Summary of the content on the page No. 5

HEAT ALARM LOCATIONS Install a heat alarm as close to the center of the ceiling as possible. If the center is not practical, mount the heat alarm no closer than 4 inches from a wall or corner. If the ceiling is not practical or the mounting surface becomes considerably warmer or cooler than the room, such as a poorly insulated ceiling, below an unfinished attic or an exterior wall (if local codes allow), install the heat alarm on inside walls with the top of the alarm between 4 and 12 inches fro

Summary of the content on the page No. 6

INSTALLATION Installation of this unit must conform to the electrical codes in your area; Article 760 of the National Electrical Code, NFPA 72, 101; SBC (SBCCI); UBC (ICBO); NBC (BOCA): OTFDC (CABO), and any other local or building codes that may apply. Wiring and installation must be performed by a licensed electrician. Failure to follow these guidelines may result in injury or property damage. This unit must be powered by a 24-hour, 120V AC 60Hz circuit. Be sure the circuit cannot be turned of

Summary of the content on the page No. 7

Interconnected CO alarms will only respond if a CO alarm / event initiates the alarm. All other alarms remain silent. Interconnected smoke alarms, heat alarms and relay modules will only respond if a smoke alarm / event or heat alarm / event initiates the alarm. All CO alarms remain silent. NOTE: Relay Modules/USI-960 will not respond if a CO alarm / event initiates the alarm. NOTE: Units without battery backup will not respond during an AC power failure. The yellow wire is used only for multipl

Summary of the content on the page No. 8

OPERATION, TESTING & MAINTENANCE OPERATION: The heat alarm is operating once the power is connected and turned o on (the battery must also be installed). When air temperature above 135 F is sensed, the unit sounds a loud alarm which continues until the air is cleared. This alarm incorporates the internationally recognized horn signal for evacuation. During alarm mode, the horn produces three short beeps followed by a two second pause and then repeats. This pattern is somewhat different than the

Summary of the content on the page No. 9

DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room. Second story windows may need a rope or chain ladder. o Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. o Determine a place outside your home where all of you can meet if a fire occurs. o Familiarize everyone with the sound of the heat alarm and train them to leave your home when they hear

Summary of the content on the page No. 10

USI FIVE YEAR LIMITED WARRANTY USI ELECTRIC, INC. ("USI") warrants your USI product to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal residential use and service. If this product is found to be defective, USI's only obligation, and your exclusive remedy, is the repair or replacement of the product, at USI's discretion, provided that the pr


Alternative user manuals
# User manual Category Download
1 Universal Security Instruments 2975L User manual Smoke Alarm 0
2 Universal Security Instruments 3304 User manual Smoke Alarm 0
3 Universal Security Instruments 3304L User manual Smoke Alarm 0
4 Universal Security Instruments 3895L User manual Smoke Alarm 0
5 Universal Security Instruments 3885 User manual Smoke Alarm 0
6 Universal Security Instruments MI5050 User manual Smoke Alarm 2
7 Universal Security Instruments 3895 User manual Smoke Alarm 0
8 Universal Security Instruments 3303 User manual Smoke Alarm 0
9 Universal Security Instruments MI3050 User manual Smoke Alarm 0
10 Universal Security Instruments MI3050L User manual Smoke Alarm 0
11 Universal Security Instruments MI5050L User manual Smoke Alarm 0
12 Universal Security Instruments MP117L User manual Smoke Alarm 0
13 Universal Security Instruments MP117 User manual Smoke Alarm 0
14 Universal Security Instruments MPI305L User manual Smoke Alarm 0
15 Universal Security Instruments SS-775-LR User manual Smoke Alarm 0
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7