Sanyo C1852 user manual

User manual for the device Sanyo C1852

Device: Sanyo C1852
Category: Air Conditioner
Manufacturer: Sanyo
Size: 0.28 MB
Added : 5/4/2013
Number of pages: 45
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo C1852. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo C1852.

For your convenience

If looking through the Sanyo C1852 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo C1852 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo C1852 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo C1852 User manual - Online PDF
Advertisement
« Page 1 of 45 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo C1852 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo C1852. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL DATA
&
FILE NO.
SERVICE MANUAL
XS1852 / C1852, CL1852
SPLIT SYSTEM AIR CONDITIONER
INDOOR MODEL No. PRODUCT CODE No. OUTDOOR MODEL No. PRODUCT CODE No.
C1852 852 068 35
XS1852 854 016 13
CL1852 852 068 36
Indoor Unit Outdoor Unit
XS1852 C1852
CL1852
85464849179000 REFERENCE NO. SM830079

Summary of the content on the page No. 2

Important When Installing Please Read Before Starting …………………………………………………………………… …In a Room This air conditioning system meets strict safety and operating Properly insulate any tubing run inside a room to prevent standards. As the installer or service person, it is an important “sweating” that can cause dripping and water damage to walls part of your job to install or service the system so it operates and floors. safely and efficiently. …In Moist or Uneven Locations For safe installation and tro

Summary of the content on the page No. 3

Table of Contents 1. OPERATING RANGE ....................................................................................... 5 2. SPECIFICATIONS ............................................................................................ 6 (1) Unit Specifications ...................................................................................... 6 (2) Major Component Specifications ................................................................ 8 (A) Indoor Unit .............................

Summary of the content on the page No. 4

Introduction: Read Me First! This manual will help you understand and service the air conditioner. To help you find the information you need, we have divided it into 5 main sections. Each section is divided into chapters with charts, tables and explana- tions to help you find and repair problems. q Section 1: Specifications, tells you about the physical and electrical make up of the unit, as well as its heating and cooling capacities. Look in this section to find the correct values for componen

Summary of the content on the page No. 5

1. OPERATING RANGE XS1852 / C1852 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115 °F DB Minimum 67 °F DB / 57 °F WB 67 °F DB XS1852 / CL1852 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115 °F DB Minimum 67 °F DB / 57 °F WB 0 °F DB SM830079 – 5 –

Summary of the content on the page No. 6

2. SPECIFICATIONS (1) Unit Specifications MODEL No. Indoor Unit XS1852 Outdoor Unit C1852 , CL1852 POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity BTU / h 18,000 17,500 kW 5.27 5.13 Air circulation (Hi) cu.ft. / min. 540 510 Moisture removal (High) Pints / h 5.5 5.4 ELECTRICAL RATINGS Voltage rating VAC 230 208 Available voltage range VAC 187 - 253 Running amperes* A 8.2 8.77 Max. running amperes** A 9.7 10.6 Power input W 1,780 1,740 Power factor % 97 98 S.E.E.R BTU / Wh

Summary of the content on the page No. 7

2. SPECIFICATIONS (1) Unit Specifications DIMENSIONS & WEIGHT Indoor unit Outdoor unit Unit dimensions Height in. (mm) 9-27/32 (250) 24-19/32 (625) Width in. (mm) 29-29/32 (760) 32-21/32 (880) Depth in. (mm) 29-29/32 (760) 12-19/32 (320) Net weight lbs. (kg) 49 (22) 104 (47) Indoor grille dimensions Height in. (mm) 3-1/16 (78) Width in. (mm) 33-27/32 (860) Depth in. (mm) 33-27/32 (860) Net weight lbs. (kg) 11 (5) Indoor Unit Height in. (mm) 11-6/32 (284) 27-30/32 (710) Package dimensions Width i

Summary of the content on the page No. 8

2. SPECIFICATIONS (2) Major Component Specifications (A) Indoor Unit MODEL No. XS1852 Source 230 - 208 V / 1 phase / 60 Hz Remote controller (Accessory) RCS - 5PS4U Controller P. C. B Ass'y CR - TS2432 Control circuit fuse 250 V, 3 A Switch Ass'y SW - X363GS Fan (Number … diameter) in. (mm) Turbo (1…19-9/32 (490)) Fan motor Model SFG6X - 41A5P Source 230 - 208 V / 1 phase / 60 Hz No. of pole … r.p.m. (230 V, High) rpm 6 … 451 Nominal output W 40 Coil resistance Ω BRW - WHT : 114.0 , ORG - YEL :

Summary of the content on the page No. 9

2. SPECIFICATIONS (2) Major Component Specifications (B) Outdoor Unit MODEL No. C1852 CL1852 Source 230 - 208 V / 1 phase / 60 Hz Controller P.C.B. Ass'y — POW - CL125 Control circuit fuse 250 VAC, 5 A Compressor Rotary (Hermetic) Model C - R132H6D Source 230 - 208 V / 1 phase / 60 Hz Nominal output W 1,300 Compressor oil cc 500 Coil resistance (Ambient temperature 77 °F) Ω C – R : 1.442 , C – S : 2.567 Safety device Internal type Overload relay models — Operating temperature Open °F 311 ± 9 Clo

Summary of the content on the page No. 10

2. SPECIFICATIONS (3) Other Component Specifications (A) Indoor Unit MODEL No. XS1852 Power Transformer ATR – I104A Rated Primary AC 220 V, 60 Hz Secondary 10.6 V, 0.93 A Capacity 9.85 VAC Coil resistance Ω WHT - WHT : 101 , BRN - BRN : 0.42 (Ambient temprature 77 °F) Thermistor cut off temperature °F266 Thermistor (Coil sensor) PBC - 41E - S26 Coil resistance kΩ 14 °F : 23.7 , 41 °F : 12.1 23 °F : 18.8 , 50 °F : 9.7 32 °F : 15.0 , 59 °F : 8.0 Thermistor (Room or coil sensor) KTEC - 35 - S6 Coil

Summary of the content on the page No. 11

2. SPECIFICATIONS (3) Other Component Specifications (B) Outdoor Unit MODEL No. CL1852 Compressor Motor Magnetic Contactor – Coil rated – Coil resistance (at 77 °F) kΩ – Contact rated (Main) – Contact rated (Auxiliary) – Power Transformer ATR - T5 Rated Primary VAC 220 VAC, 60 Hz Secondary 19 V, 15 A Capacity 10 VA Coil resistance (at 77 °F) Ω Primary (WHT - WHT) : 385 ± 10 % Secondary (BRN - BRN) : 3.3 ± 10 % Thermal cut off temperature °F 276 ˚F, 1A 250 VAC Thermistor (Outdoor Temp. sensor)

Summary of the content on the page No. 12

3. DIMENSIONAL DATA (1) Indoor Unit: XS1852 8-21/32 8-1/16 4-29/32 • Remote controller (Accessory) 2-13/32 23/32 4-29/32 5-29/32 7-7/8 10-1/32 32-9/32 (Ceiling opening) 11-23/32 1-3/16 33-27/32 19-11/16 8-1/16 23-7/32 (Suspention bolt pitch) 6-1/2 14 1-7/8 4-29/32 Min. 2-3/8 3-1/32 Dimension : inch Air intake Air outlet Narrow tube (1/4") Wide tube (5/8") Drain connection Power line (conduit size : 1/2") For discharge duct Suspention bolt mounting 1331_X_S SM830079 – 12 – X 12 Grille center X

Summary of the content on the page No. 13

3. DIMENSIONAL DATA (2) Outdoor Unit: C1852, CL1852 Air intake 4-ø15/32" 23-15/16" 5-11/32" 15/32" Air discharge 34-21/32" 12-19/32" Narrow tube service valve ø1/4 (6.35) Wide tube service valve ø5/8 (15.88) Unit: inch (mm) 1880_C_I SM830079 – 13 – 3-7/16" 2-5/32" 5/8" 12-7/32" 21-19/32" 13-5/32"

Summary of the content on the page No. 14

4. PERFORMANCE CHARTS (1) Operating Current 11111 Indoor Unit: XS1852 Outdoor Unit: C1852, CL1852 Operating current characteristics versus outdoor ambient temperature and indoor temperature. (Indoor relative humidity: 50%, Indoor fan speed: High) 230V Indoor inlet air 12 D.B. temp. °F (°C) 11 95 (35.0) 10 80 (26.7) 67 (19.4) 9 8 7 6 5 60 70 80 90 100 110 120 (15.6) (21.1) (26.7) (32.2) (37.8) (43.3) (48.9) Outdoor inlet air D.B. temp. °F (°C) 1881_M_I 230V / 208V Indoor inlet air 150 (10.5) D.B.

Summary of the content on the page No. 15

5. AIR THROW DISTANCE CHART MODEL: XS1852 HORIZONTAL DISTANCE (ft.) 0 3 7 101317 20 0 3 AXIS AIR VELOCITY 7 10 13 COOLING FAN SPEED HIGH ROOM AIR TEMP. 80˚F 30˚ LOUVER ANGLE 1052_X_S SM830079 – 15 – AXIS AIR VELOCITY (ft./sec.) VERTICAL DISTANCE (ft.)

Summary of the content on the page No. 16

6. REFRIGERANT FLOW DIAGRAM Indoor Unit: XS1852 Outdoor Unit: C1852, CL1852 Indoor Unit Outdoor Unit Wide tube Wide tube service valve Accumulator O. D. 5/8" (15.88 mm) Narrow tube Capillary Narrow tube service valve tube O. D. 1/4" (6.35 mm) Insulation of Refrigerant Tubing IMPORTANT Insulation To prevent heat loss and wet floors due to dripping of condensation, both the wide and narrow tubes Thickness: Thickness: Min. 5/16 in. Min. 5/16 in. must be well insulated with a proper insulation mat

Summary of the content on the page No. 17

7. INSTALLATION INSTRUCTIONS 1) Tubing Length • Refrigerant tubing between the indoor and Tubing length (L) INDOOR UNIT outdoor units should be kept as short as possible. • Select and decide the installation location Elevation difference (H) OUTDOOR so that the length of the refrigerant tubing UNIT will be within the limits given in Table 1. 0711_M_I Fig. 1 Table 1 Models C1852 Tubing Data CL1852 Narrow tube in. (mm) 1/4 (6.35): Thickness 0.0314" (0.8 mm) Tubing size outer dia. Wide tube in. (mm

Summary of the content on the page No. 18

7. INSTALLATION INSTRUCTIONS 2) Selecting the Installation Site Indoor Unit AVOID: ã areas where leakage of flammable gas may be expected. ã places where large amount of oil mist exist. ã direct sunlight. ã locations near heat sources which may affect performance of the unit. ã locations where external air may enter the room directly. This may cause “sweating” on the air discharge ports, causing them to spray or drip. ã locations where the remote control unit will be splashed with water or affec

Summary of the content on the page No. 19

About 16" (40 cm) 7. INSTALLATION INSTRUCTIONS Exhaust fan NO Outdoor Unit Hot air AVOID: Heat source ã heat sources, exhaust fans, etc. (Fig. 3) Out- door ã damp, humid or uneven locations. unit DO: 1817_C_I ã choose a place as cool as possible. Fig. 3 ã choose a place that is well ventilated. Obstacle above ã allow enough room around the unit for air intake/ exhaust and possible maintenance. (Fig. 4) Min. Min. ã Install the outdoor unit 7 ft. 7 ft. Air intake Min. 6" (15 cm) CAUTION (2 m) abov

Summary of the content on the page No. 20

7. INSTALLATION INSTRUCTIONS 4) Electrical Wiring (7) Regulations on wire diameters differ from General Precautions on Wiring (1) Before wiring, confirm the rated voltage locality to locality. For field wiring rules, of the unit as shown on its nameplate, please refer to your LOCAL ELECTRI- then carry out the wiring closely following CAL CODES (ex. National Electric Code: the wiring diagram. ANSI/NFPA70) before beginning. You must ensure that installation complies (2) Provide a power outlet to b


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21