Carrier WEATHERMASTER ZN030-105 user manual

User manual for the device Carrier WEATHERMASTER ZN030-105

Device: Carrier WEATHERMASTER ZN030-105
Category: Computer Accessories
Manufacturer: Carrier
Size: 0.5 MB
Added : 12/16/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier WEATHERMASTER ZN030-105. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier WEATHERMASTER ZN030-105.

For your convenience

If looking through the Carrier WEATHERMASTER ZN030-105 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier WEATHERMASTER ZN030-105 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier WEATHERMASTER ZN030-105 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier WEATHERMASTER ZN030-105 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier WEATHERMASTER ZN030-105 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier WEATHERMASTER ZN030-105. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

48ZG,ZN030-105
48ZT,ZW,Z6,Z8075-105
Gas Heating/Electric Cooling Units
with COMFORTLINK™ Controls
User’s Information Manual
NOTE TO INSTALLER: TO LIGHT UNIT
This manual should be left with the equipment owner.
1. Do not turn off the electrical power to unit without
WARNING: If the information in this
first turning off the gas supply.
manual is not followed exactly, a fire or
2. Before attempting to start the gas heating section,
explosion may result causing property
familiarize yourself with all

Summary of the content on the page No. 2

NOTE: High heat consists of sections 1 and 2. Low heat consists NOTE: High heat consists of sections 1-3. Low heat consists of of section 1 only. sections 1 and 2 only. 030-050 SIZES 055-105 SIZES Fig. 1 — Heat Section Details 10. Using the scrolling marquee, enable the unit to run using 11. To test the operation of the gas section, use the scrolling the following procedure: marquee Service Test routine to energize the gas outputs and to turn on the gas. Refer to the unit Controls, Start- ESCAPE

Summary of the content on the page No. 3

MAIN MODE ON Run Status Service Test Temperature Pressures Setpoints Alarm Status Inputs Outputs Configuration ESCAPE ENTER Time Clock Operating Modes Alarms OFF STEP 1 STEP 2 STEP 3 a48-8297 STEP 5 STEP 4 a48-8298 STEP 6 STEP 7 MODE Run Status Service Test Temperature Pressures Setpoints Alarm Status Inputs Outputs Configuration ESCAPE ENTER Time Clock Operating Modes Alarms STEP 8 STEP 9 STEP 10 Fig. 2 — To Light Unit 3 LOCK-OUT TAG

Summary of the content on the page No. 4

For your safety, keep the gas heating area clear and free of TO SHUT UNIT OFF combustible materials, gasoline, and other flammable liquids and vapors. To ensure proper functioning of the unit, flow of combus- Do not turn off the electrical power to unit without first tion and ventilating air must not be obstructed from reaching turning off the gas supply. the gas heating area. Clearance of at least 4 ft on all sides is required. Never attempt to manually light the main burners on a unit with a m

Summary of the content on the page No. 5

When replacing your unit filters, always use the same size Heat Exchanger — To ensure dependable and efficient and type of filter that was originally supplied by the installer. heating operation, the heat exchanger should be checked by a qualified maintenance person before each heating season, and Units with outdoor air capability have a cleanable filter for cleaned when necessary. This checkout should not be attempt- the outdoor air. This filter should be checked annually and ed by anyone not h

Summary of the content on the page No. 6

SIZES 030-050 (040 SHOWN) SIZES 055-070 POWER EXHAUST VFD ACCESS DOOR ACCESS DOOR (NEAR SIDE) FLUE OUTLETS (NEAR SIDE ONLY) ACCESS DOOR (FAR SIDE ONLY) POWER EXHAUST (FAR SIDE) (BOTH SIDES) ACCESS DOOR CONTROL BOX CONTROL BOX (FAR SIDE ONLY) (FAR SIDE) GAS SECTION ACCESS DOOR POWER EXHAUST ACCESS DOOR ACCESS DOOR FILTER (BOTH SIDES) (BOTH SIDES) (FAR SIDE) ACCESS SIZES 075-105 Fig. 4 — Door Locations (48Z Series Units) 6

Summary of the content on the page No. 7

See Fig. 1 and 5 and proceed as follows to inspect the com- Fan and Belts — Periodically check the condition of fan bustion area and power-venting system of your unit. wheels and housings and belt tension. When service is neces- sary, call your dealer. 1. Turn off gas supply and then electrical power to your unit. 2. Open gas section access door. Evaporator-Fan Motor, Condenser-Fan Motor and Combustion-Fan Motor — Lubrication is not 3. Using a flashlight, carefully inspect the burner areas for r

Summary of the content on the page No. 8

REGULAR DEALER MAINTENANCE BEFORE YOU CALL FOR SERVICE, CHECK FOR SEVERAL EASILY SOLVED PROBLEMS In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a If insufficient heat or cooling is suspected: properly trained service technician. An inspection (preferably ( ) Check for sufficient airflow. Check the air filters for dirt. each year, but at least every other year) should include the Check for blocked return-air or supply-air


Alternative user manuals
# User manual Category Download
1 Carrier WEATHERMASTER 48ZT User manual Computer Accessories 3
2 Carrier WEATHERMASTER 48ZG User manual Computer Accessories 0
3 Carrier WEATHERMASTER Z8075-105 User manual Computer Accessories 1
4 Carrier WEATHERMASTER ZW User manual Computer Accessories 0
5 Carrier WEATHERMASTER Z6 User manual Computer Accessories 1
6 Carrier WEATHERMASTER ZN030-105 User manual Heating System 1
7 Sony VGC-RB50(G) User manual Computer Accessories 1
8 Sony Movie Studio HD Platinum Suite 11 MSPSMS11000 User manual Computer Accessories 177
9 Sony Hi-MD Walkman MCMD-R1 User manual Computer Accessories 7
10 Sony Sound Forge V.10.0 Pro SF-10000 User manual Computer Accessories 435
11 Sony Rechargable Battery Pack VGP-BPSC31 User manual Computer Accessories 23
12 Sony SMP-N100 User manual Computer Accessories 10
13 Sony VGP-BPS13 User manual Computer Accessories 1
14 Sony VGP-BPS22A User manual Computer Accessories 2
15 Sony Walkman NWZ-S616F User manual Computer Accessories 48